Min-Woo Ham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Min-Woo Ham has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Amphol Aphathanakorn
National Innovation Agency, 73/2 Rama VI Road, Rajdhevee, Bangkok 10400, Thailand
1 shared publication - Dongmyoung Kim
Department of Integrated Energy and Infra System, Kangwon National University, Chuncheon-si 24341, Gangwon, Republic of Korea
1 shared publication - Insu Paek
Kangwon National University
1 shared publication - Wirachai Roynarin
Department of Electrical Engineering, Faculty of Engineering, Rajamangala University of Technology Thanyaburi, Pathum Thani 12110, Thailand
1 shared publication
Latest Publications
- Open Access
- 12 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (24) , 11598
Performance Validation of Control Algorithm Considering Independent Generator Torque Control in PCS
This study designed and validated a power control algorithm tailored to the unique characteristics of a 100 kW wind turbine equipped with an independent generator torque control system within the Power Conversion System (PCS). Unlike conventional power control methods based on the Programmable Logic Controller (PLC), the independent generator torque control in the PCS estimates the generator speed based on the voltage signal and performs the generator torque control without any interference from the PLC. The conventional power control algorithm in the PLC was modified so that the PLC could perform the power control by the blade pitch control only. Furthermore, a mode transition algorithm was designed to improve the shortcomings of the mode switch previously used for transitioning between the torque and pitch control modes. To verify the performance, a simulation environment similar to actual control conditions was established using a commercial analysis program, and dynamic simulations were conducted. Additionally, for the experimental validation, the proposed control algorithm was applied to a scaled wind turbine, and wind tunnel tests were performed. The results of the simulations and wind tunnel tests confirmed the operational performance of the PCS’s torque control and the improved control transition logic. The proposed control algorithm could be specifically applied to medium-sized wind turbines employing a sensorless generator speed estimation method and independent generator torque control in the PCS.
- 12 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (24) , 11598
Open AccessPerformance Validation of Control Algorithm Considering Independent Generator Torque Control in PCS
This study designed and validated a power control algorithm tailored to the unique characteristics of a 100 kW wind turbine equipped with an independent generator torque control system within the Power Conversion System (PCS). Unlike conventional power control methods based on the Programmable Logic Controller (PLC), the independent generator torque control in the PCS estimates the generator speed based on the voltage signal and performs the generator torque control without any interference from the PLC. The conventional power control algorithm in the PLC was modified so that the PLC could perform the power control by the blade pitch control only. Furthermore, a mode transition algorithm was designed to improve the shortcomings of the mode switch previously used for transitioning between the torque and pitch control modes. To verify the performance, a simulation environment similar to actual control conditions was established using a commercial analysis program, and dynamic simulations were conducted. Additionally, for the experimental validation, the proposed control algorithm was applied to a scaled wind turbine, and wind tunnel tests were performed. The results of the simulations and wind tunnel tests confirmed the operational performance of the PCS’s torque control and the improved control transition logic. The proposed control algorithm could be specifically applied to medium-sized wind turbines employing a sensorless generator speed estimation method and independent generator torque control in the PCS.