THTianding Han

Tianding Han

*This is an algorithmically generated author record based on publicly available information.

Tianding Han has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimization of Inlet Flow Pattern and Performance Enhancement in Oil-Gas Multiphase Pumps Using Helical Static Mixer

    by Wei Han, Lingrui Zhu, Longlong Zhao, Huiyu Chen, Hongfa Huang, Wanquan Deng, Lei Ji

    With increasing global energy demand and depletion of onshore oil–gas resources, deep-sea hydrocarbon exploration and development have become strategically vital. As core subsea transportation equipment, the performance of helico-axial multiphase pumps directly determines the efficiency and economic feasibility of deep-sea extraction. However, non-uniform inflow patterns caused by uneven gas–liquid distribution in pipelines degrade pressure-boosting capability and reduce pump efficiency under actual operating conditions. To address this, an optimization method employing helical static mixers was developed. A mixer with a 180° helical angle was designed and installed upstream of the pump inlet. Numerical simulations demonstrate that the mixer enhances gas-phase distribution uniformity in stratified flow, improving efficiency and head across varying gas void fractions (GVFs). At a stratification height ratio (Ψ) of 0.32, efficiency increased by 15.41% and head rose by 15.64 m, while turbulent kinetic energy (TKE) at the impeller outlet decreased by up to 50%. For slug flow conditions, the mixer effectively suppressed gas volume fraction fluctuations, consistently improving efficiency under different slug flow coefficients (φ) with a maximum head increase of 9.82%. The optimized flow field exhibits uniform gas–liquid velocity distribution, stable pressure boosting, and significantly reduced TKE intensity within impeller passages.


  • Open Access

    Effect of Guide Vane Opening on Flow Distortion and Impeller Stress in a Pump-Turbine Under Extremely Low-Head Conditions

    by Xiangyu Chen, Qifei Li, Lu Xin, Shiang Zhang, Mingjie Cheng, Tianding Han

    Under extremely low-head conditions, the performance and stability of pump-turbine units are strongly influenced by the flow distortion caused by variations in guide vane opening. In this study, a pump-turbine model—representative of a domestic pumped storage power station—was investigated through a combination of experimental observations and three-dimensional unsteady numerical simulations employing the SST k-ω turbulence model. The analysis focused on characterizing the variations in turbulence kinetic energy, pressure pulsations, and impeller force fluctuations as the guide vane opening was altered. The results reveal that, with increasing guide vane opening, the turbulence kinetic energy within the impeller region is notably reduced. This reduction is primarily attributed to a decrease in energy losses along the suction surfaces of the blades and within the straight pipe section of the tailwater tunnel. Simultaneously, pressure pulsations were detected at multiple locations including the volute inlet, the blade-free zone, downstream of the conical pipe, and along the inner surface of the shaft tube. While most regions experienced a decline in pressure pulsation intensity with larger openings, the bladeless zone exhibited a significant increase. Moreover, force analysis at four distinct guide vane settings indicated that an opening of 41 mm resulted in relatively uniform fluctuations in the impeller forces. This uniformity suggests that an optimal guide vane configuration exists, which minimizes uneven stress distributions and enhances the operational stability of the pump-turbine under extremely low-head conditions. These findings offer valuable insights for the design and operational optimization of pump-turbine systems in pumped storage power stations.


  • Open Access

    Study on the Influence of Reynolds Number on Heat Exchange Performance and Nusselt Number of Spray Coil Heat Exchanger

    by Tianding Han, Qifei Li, Lin Shang, Xiangyu Chen, Feng Zhou, Wangxu Li

    Biomass clean energy is widely used as an alternative to fossil fuels due to its advantages of low carbon emissions, cleanliness, and renewability. Biomass fuel exchangers are important equipment for heat exchange between air and exhaust gasses after biomass combustion, and the air flow rate and structural characteristics of the exchanger have a significant impact on the heat transfer performance. In order to investigate the effect of Reynolds number on the heat transfer performance of the exchanger when air flows through, a serpentine tube heat exchange test bench was constructed, and numerical calculations were performed using the Realizable k-ε turbulence model for the entire channel. By changing the diameter and pitch of the serpentine tube, the effects of geometric parameters on the heat transfer performance were studied, and the flow characteristics of exhaust gasses and air inside the exchanger under various operating conditions were deduced. Subsequently, experimental validation was conducted by referring to the boundary conditions of numerical calculations, obtaining corresponding test data, and comparing the numerical and experimental results, showing that the errors in various physical quantities were within 5%. Through comprehensive analysis of the data, it was found that when the serpentine tube diameter is 80 mm and pitch is 300 mm, the Nusselt number (Nu) increased most significantly with Reynolds number (Re) by 25.17%, indicating the best heat transfer performance. Additionally, reducing tube diameter, increasing serpentine tube pitch, enlarging air-inlet flow velocity can enhance Re, increase fluid disturbance, and improve convective heat transfer intensity, thereby increasing Nu and strengthening the heat transfer performance of the serpentine tube exchanger.


  • Open Access

    Impact of Outlet Pressure on Internal Flow Characteristics and Energy Loss in Pump-Turbine System Under Pump Operation Conditions

    by Tianding Han, Qifei Li, Licheng Feng, Xiangyu Chen, Feng Zhou, Zhenggui Li

    During pump operation, the pump-turbine system experiences unstable fluctuations in outlet pressure, which induces turbulence and additional energy losses. Understanding the impact of outlet pressure variations on the internal flow field is crucial for the further development of turbine units. This study employs numerical methods to systematically analyze the effects of outlet pressure changes on flow characteristics and energy loss. The results show that a decrease in outlet pressure to P0.9BEP significantly increases entropy production in the double-row stay guide vane region, primarily due to flow separation and vortex formation. In the flow passage, sealing gap, and tailpipe regions, entropy production is mainly driven by wall effects, while secondary flows influence the spiral case. The vortex distribution in the double-row stay guide vane is complex, with different variation trends observed in the active and fixed guide vane regions. Outlet pressure changes affect the interaction between the flow passage blades and the fluid, leading to localized flow separation and directly impacting energy loss in downstream components. Additionally, the rate of change in outlet pressure significantly influences vortex generation and dissipation. This research provides new theoretical insights and research directions for performance optimization and energy loss control in pump-turbine systems.