Feng Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Feng Zhou has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Qifei Li
School of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou 730050, China
4 shared publications - Licheng Feng
College of New Energy Engineering, Jiuquan Vocational Technical College, Jiuquan 735000, China
3 shared publications - Xiangyu Chen
School of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou 730050, China
3 shared publications - Tianding Han
College of New Energy Engineering, Jiuquan Vocational Technical College, Jiuquan 735000, China
2 shared publications - Ling Li
Hubei Technology Innovation Center for Smart Hydropower, Wuhan 430000, China
1 shared publication - Lu Xin
School of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou 730050, China
1 shared publication
Latest Publications
- Open Access
Experimental Study on the Correlation Between Unstable Flow and Cavitation Vibration of Pump-Wheel Cascade
In order to deeply reveal the coupling mechanism of flow and cavitation evolution inside the pump–turbine under hump conditions, this paper combines numerical simulation of multiphase flow with high-speed imaging experiments and systematically analyzes the structure of non-constant flow and its induced hydraulic excitation behavior. It is found that as the cavitation number decreases from 0.33 to 0.072, the vacuole morphology in the impeller develops from incipient bright spots to U-shaped cavitation clouds, and vortex cavitation and lamellar cavitation meet at the trailing edge, which triggers a strong perturbation in the flow channel. At the same time, large-scale flow separation develops on the pressure surface, accompanied by intensified vortex structures on the suction surface and a highly non-uniform circumferential velocity distribution at the guide-vane inlet. These flow distortions significantly increase the hydraulic excitation of the system. The three-dimensional connection and asymmetric distribution of the vacuoles exacerbate the load imbalance between the channels, which is the main cause of efficiency loss and structural vibration enhancement. The pressure pulsation spectrum is accompanied by multiple high-frequency and low-frequency excitation peaks, especially in the 20–33 Hz band, which reveals the multi-source coupling mechanism between cavitation behavior, reflux shear, and modal response. The results provide theoretical support for the in-depth understanding of the instability evolution mechanism of the pump–turbine and operation optimization under complex working conditions.
Open AccessExperimental Study on the Correlation Between Unstable Flow and Cavitation Vibration of Pump-Wheel Cascade
In order to deeply reveal the coupling mechanism of flow and cavitation evolution inside the pump–turbine under hump conditions, this paper combines numerical simulation of multiphase flow with high-speed imaging experiments and systematically analyzes the structure of non-constant flow and its induced hydraulic excitation behavior. It is found that as the cavitation number decreases from 0.33 to 0.072, the vacuole morphology in the impeller develops from incipient bright spots to U-shaped cavitation clouds, and vortex cavitation and lamellar cavitation meet at the trailing edge, which triggers a strong perturbation in the flow channel. At the same time, large-scale flow separation develops on the pressure surface, accompanied by intensified vortex structures on the suction surface and a highly non-uniform circumferential velocity distribution at the guide-vane inlet. These flow distortions significantly increase the hydraulic excitation of the system. The three-dimensional connection and asymmetric distribution of the vacuoles exacerbate the load imbalance between the channels, which is the main cause of efficiency loss and structural vibration enhancement. The pressure pulsation spectrum is accompanied by multiple high-frequency and low-frequency excitation peaks, especially in the 20–33 Hz band, which reveals the multi-source coupling mechanism between cavitation behavior, reflux shear, and modal response. The results provide theoretical support for the in-depth understanding of the instability evolution mechanism of the pump–turbine and operation optimization under complex working conditions.
- Open Access
Cavitation Performance Analysis in the Runner Region of a Bulb Turbine
As a core component in renewable energy systems for grid regulation, hydropower units are increasingly exposed to flow conditions that elevate the risk of cavitation and erosion, posing significant challenges to the safe operation of flow-passage components. In this study, model testing and computational fluid dynamics (CFD) simulations are employed to investigate the hydraulic performance and cavitation behavior of a bulb turbine operating under rated head conditions and varying cavitation numbers. The analysis focuses on how changes in cavitation intensity affect flow characteristics and efficiency within the runner region. The results show that as the cavitation number approaches its critical value, the generation, growth, and collapse of vapor cavities increasingly disturb the main flow, causing a marked drop in blade hydraulic performance and overall turbine efficiency. Cavitation predominantly occurs on the blade’s suction side near the trailing edge rim and in the clearance zone near the hub, with bubble coverage expanding as the cavitation number decreases. A periodic inverse correlation between surface pressure and the cavitation area is observed, reflecting the strongly unsteady nature of cavitating flows. Furthermore, lower cavitation numbers lead to intensified pressure pulsations, aggravating flow unsteadiness and raising the risk of vibration.
Open AccessCavitation Performance Analysis in the Runner Region of a Bulb Turbine
As a core component in renewable energy systems for grid regulation, hydropower units are increasingly exposed to flow conditions that elevate the risk of cavitation and erosion, posing significant challenges to the safe operation of flow-passage components. In this study, model testing and computational fluid dynamics (CFD) simulations are employed to investigate the hydraulic performance and cavitation behavior of a bulb turbine operating under rated head conditions and varying cavitation numbers. The analysis focuses on how changes in cavitation intensity affect flow characteristics and efficiency within the runner region. The results show that as the cavitation number approaches its critical value, the generation, growth, and collapse of vapor cavities increasingly disturb the main flow, causing a marked drop in blade hydraulic performance and overall turbine efficiency. Cavitation predominantly occurs on the blade’s suction side near the trailing edge rim and in the clearance zone near the hub, with bubble coverage expanding as the cavitation number decreases. A periodic inverse correlation between surface pressure and the cavitation area is observed, reflecting the strongly unsteady nature of cavitating flows. Furthermore, lower cavitation numbers lead to intensified pressure pulsations, aggravating flow unsteadiness and raising the risk of vibration.
- Open Access
Study on the Influence of Reynolds Number on Heat Exchange Performance and Nusselt Number of Spray Coil Heat Exchanger
Biomass clean energy is widely used as an alternative to fossil fuels due to its advantages of low carbon emissions, cleanliness, and renewability. Biomass fuel exchangers are important equipment for heat exchange between air and exhaust gasses after biomass combustion, and the air flow rate and structural characteristics of the exchanger have a significant impact on the heat transfer performance. In order to investigate the effect of Reynolds number on the heat transfer performance of the exchanger when air flows through, a serpentine tube heat exchange test bench was constructed, and numerical calculations were performed using the Realizable k-ε turbulence model for the entire channel. By changing the diameter and pitch of the serpentine tube, the effects of geometric parameters on the heat transfer performance were studied, and the flow characteristics of exhaust gasses and air inside the exchanger under various operating conditions were deduced. Subsequently, experimental validation was conducted by referring to the boundary conditions of numerical calculations, obtaining corresponding test data, and comparing the numerical and experimental results, showing that the errors in various physical quantities were within 5%. Through comprehensive analysis of the data, it was found that when the serpentine tube diameter is 80 mm and pitch is 300 mm, the Nusselt number (Nu) increased most significantly with Reynolds number (Re) by 25.17%, indicating the best heat transfer performance. Additionally, reducing tube diameter, increasing serpentine tube pitch, enlarging air-inlet flow velocity can enhance Re, increase fluid disturbance, and improve convective heat transfer intensity, thereby increasing Nu and strengthening the heat transfer performance of the serpentine tube exchanger.
Open AccessStudy on the Influence of Reynolds Number on Heat Exchange Performance and Nusselt Number of Spray Coil Heat Exchanger
Biomass clean energy is widely used as an alternative to fossil fuels due to its advantages of low carbon emissions, cleanliness, and renewability. Biomass fuel exchangers are important equipment for heat exchange between air and exhaust gasses after biomass combustion, and the air flow rate and structural characteristics of the exchanger have a significant impact on the heat transfer performance. In order to investigate the effect of Reynolds number on the heat transfer performance of the exchanger when air flows through, a serpentine tube heat exchange test bench was constructed, and numerical calculations were performed using the Realizable k-ε turbulence model for the entire channel. By changing the diameter and pitch of the serpentine tube, the effects of geometric parameters on the heat transfer performance were studied, and the flow characteristics of exhaust gasses and air inside the exchanger under various operating conditions were deduced. Subsequently, experimental validation was conducted by referring to the boundary conditions of numerical calculations, obtaining corresponding test data, and comparing the numerical and experimental results, showing that the errors in various physical quantities were within 5%. Through comprehensive analysis of the data, it was found that when the serpentine tube diameter is 80 mm and pitch is 300 mm, the Nusselt number (Nu) increased most significantly with Reynolds number (Re) by 25.17%, indicating the best heat transfer performance. Additionally, reducing tube diameter, increasing serpentine tube pitch, enlarging air-inlet flow velocity can enhance Re, increase fluid disturbance, and improve convective heat transfer intensity, thereby increasing Nu and strengthening the heat transfer performance of the serpentine tube exchanger.
- Open Access
Impact of Outlet Pressure on Internal Flow Characteristics and Energy Loss in Pump-Turbine System Under Pump Operation Conditions
During pump operation, the pump-turbine system experiences unstable fluctuations in outlet pressure, which induces turbulence and additional energy losses. Understanding the impact of outlet pressure variations on the internal flow field is crucial for the further development of turbine units. This study employs numerical methods to systematically analyze the effects of outlet pressure changes on flow characteristics and energy loss. The results show that a decrease in outlet pressure to P0.9BEP significantly increases entropy production in the double-row stay guide vane region, primarily due to flow separation and vortex formation. In the flow passage, sealing gap, and tailpipe regions, entropy production is mainly driven by wall effects, while secondary flows influence the spiral case. The vortex distribution in the double-row stay guide vane is complex, with different variation trends observed in the active and fixed guide vane regions. Outlet pressure changes affect the interaction between the flow passage blades and the fluid, leading to localized flow separation and directly impacting energy loss in downstream components. Additionally, the rate of change in outlet pressure significantly influences vortex generation and dissipation. This research provides new theoretical insights and research directions for performance optimization and energy loss control in pump-turbine systems.
Open AccessImpact of Outlet Pressure on Internal Flow Characteristics and Energy Loss in Pump-Turbine System Under Pump Operation Conditions
During pump operation, the pump-turbine system experiences unstable fluctuations in outlet pressure, which induces turbulence and additional energy losses. Understanding the impact of outlet pressure variations on the internal flow field is crucial for the further development of turbine units. This study employs numerical methods to systematically analyze the effects of outlet pressure changes on flow characteristics and energy loss. The results show that a decrease in outlet pressure to P0.9BEP significantly increases entropy production in the double-row stay guide vane region, primarily due to flow separation and vortex formation. In the flow passage, sealing gap, and tailpipe regions, entropy production is mainly driven by wall effects, while secondary flows influence the spiral case. The vortex distribution in the double-row stay guide vane is complex, with different variation trends observed in the active and fixed guide vane regions. Outlet pressure changes affect the interaction between the flow passage blades and the fluid, leading to localized flow separation and directly impacting energy loss in downstream components. Additionally, the rate of change in outlet pressure significantly influences vortex generation and dissipation. This research provides new theoretical insights and research directions for performance optimization and energy loss control in pump-turbine systems.