Katharina Mücke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Katharina Mücke has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Benedict Wilmes
Universitätsklinikum Düsseldorf
1 shared publication- Beryl Schwarz-Herzke
Institute of Anatomy II, Medical Faculty, Heinrich Heine University, Düsseldorf, Germany
1 shared publication - Dieter Drescher
Department of Orthodontics, University of Homburg, Saar, Germany
1 shared publication - Giulia Brunello
Department of Oral Surgery University Hospital of Düsseldorf Düsseldorf Germany
1 shared publication Kathrin Becker
Charité – Universitätsmedizin Berlin
1 shared publication- Kathrin Becker
Department of Orthodontics and Dentofacial Orthopaedics Charité – Universitätsmedizin Berlin Berlin Germany
1 shared publication
Latest Publications
- Open Access
- 4 March 2025
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 87 (3) , 269-278
Is simultaneous placement of orthodontic mini-implants and skeletally anchored appliances advisable?
Purpose: For the fabrication of an orthodontic mini-implant (OMI)-borne appliance, the position of the inserted OMI can be detected by a silicone impression or an intraoral scan (IOS). In case of digital planning, it can be taken over from the planning and the appliance can be produced in advance. This study aimed to evaluate the accuracy of these three techniques and whether there is an association with the insertion angle. Methods: Two OMIs were digitally planned and placed in the anterior palate of 11 human cadavers with different insertion angles. Subsequently, the position of each OMI was detected by an IOS, a silicone impression, and a cone-beam computed tomography (CBCT) scan, whereby the CBCT scan was set as “real position”. The measurements of accuracy were performed between the CBCT data as a reference and the preoperative digital planning, the IOS and the plaster model manufactured from the silicone impression. Results: The IOS was the most accurate in detecting the Top (mean deviation 0.14 mm) and the Apex (mean deviation 0.36 mm) of the OMIs. Significant linear deviations between the three modalities were registered for both Top ( p < 0.001) and Apex ( p = 0.010). The digital planning procedure achieved the lowest mean angular deviation of 3.7° and was significantly more accurate in this respect than the IOS ( p < 0.001). Conclusion: All methods were subject to small, but clinically irrelevant deviations. Within the limitations of a cadaver study, all methods appear to be suitable for clinical use. However, the digital workflow could be advantageous, requiring only a single visit for OMI placement and simultaneous appliance fitting.
- 4 March 2025
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 87 (3) , 269-278
Open AccessIs simultaneous placement of orthodontic mini-implants and skeletally anchored appliances advisable?
Purpose: For the fabrication of an orthodontic mini-implant (OMI)-borne appliance, the position of the inserted OMI can be detected by a silicone impression or an intraoral scan (IOS). In case of digital planning, it can be taken over from the planning and the appliance can be produced in advance. This study aimed to evaluate the accuracy of these three techniques and whether there is an association with the insertion angle. Methods: Two OMIs were digitally planned and placed in the anterior palate of 11 human cadavers with different insertion angles. Subsequently, the position of each OMI was detected by an IOS, a silicone impression, and a cone-beam computed tomography (CBCT) scan, whereby the CBCT scan was set as “real position”. The measurements of accuracy were performed between the CBCT data as a reference and the preoperative digital planning, the IOS and the plaster model manufactured from the silicone impression. Results: The IOS was the most accurate in detecting the Top (mean deviation 0.14 mm) and the Apex (mean deviation 0.36 mm) of the OMIs. Significant linear deviations between the three modalities were registered for both Top ( p < 0.001) and Apex ( p = 0.010). The digital planning procedure achieved the lowest mean angular deviation of 3.7° and was significantly more accurate in this respect than the IOS ( p < 0.001). Conclusion: All methods were subject to small, but clinically irrelevant deviations. Within the limitations of a cadaver study, all methods appear to be suitable for clinical use. However, the digital workflow could be advantageous, requiring only a single visit for OMI placement and simultaneous appliance fitting.
- 2 December 2024
- Published by Georg Thieme Verlag KG in Informationen aus Orthodontie & Kieferorthopädie
- Vol. 56 (04) , 225-231
3D-Druck palatinal verankerter Apparaturen: eine Übersicht
Zusammenfassung: Der 3D-Druck, oder auch additive Fertigung genannt, hat die Kieferorthopädie erheblich verändert. Indem er die Herstellung präziser, individuell angepasster Apparaturen ermöglicht, verbessert der 3D-Druck sowohl die Effizienz der Behandlung als auch den Patientenkomfort. In den letzten Jahren haben sich insbesondere der Einsatz von Computer-Aided Design (CAD)/Computer-Aided Manufacturing (CAM)-Systemen und Metall-3D-Druckverfahren, wie das selektive Laserschmelzen (SLM), durchgesetzt. In der Kieferorthopädie ermöglichen diese Technologien, festsitzende Apparaturen (Brackets[1], Lingualretainer [2], Hyrax-Expander[3], skelettal verankerte Apparaturen[4]), herausnehmbare Apparaturen [5] und komplexe, individualisierte Apparaturen (multipurpose Apparaturen) digital zu planen und direkt zu drucken, teilweise sogar bereits ohne die Notwendigkeit physischer Modelle [6].
- 2 December 2024
- Published by Georg Thieme Verlag KG in Informationen aus Orthodontie & Kieferorthopädie
- Vol. 56 (04) , 225-231
3D-Druck palatinal verankerter Apparaturen: eine Übersicht
Zusammenfassung: Der 3D-Druck, oder auch additive Fertigung genannt, hat die Kieferorthopädie erheblich verändert. Indem er die Herstellung präziser, individuell angepasster Apparaturen ermöglicht, verbessert der 3D-Druck sowohl die Effizienz der Behandlung als auch den Patientenkomfort. In den letzten Jahren haben sich insbesondere der Einsatz von Computer-Aided Design (CAD)/Computer-Aided Manufacturing (CAM)-Systemen und Metall-3D-Druckverfahren, wie das selektive Laserschmelzen (SLM), durchgesetzt. In der Kieferorthopädie ermöglichen diese Technologien, festsitzende Apparaturen (Brackets[1], Lingualretainer [2], Hyrax-Expander[3], skelettal verankerte Apparaturen[4]), herausnehmbare Apparaturen [5] und komplexe, individualisierte Apparaturen (multipurpose Apparaturen) digital zu planen und direkt zu drucken, teilweise sogar bereits ohne die Notwendigkeit physischer Modelle [6].