Yuliang Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuliang Zhu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Chengtao Luo
School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
4 shared publications - Xiaobo Wang
School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
4 shared publications - Tao Han
Shanghai Jiao Tong University
2 shared publications - Wenchao Xue
School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
2 shared publications - Bofeng Luo
Digital Grid Research Institute, China Southern Power Grid, GuangZhou, China
1 shared publication Chengtao Luo
School of Automation and Intelligent Sensing Shanghai Jiao Tong University Shanghai China
1 shared publication
Latest Publications
- 21 January 2026
- Published by Wiley in Journal of the American Ceramic Society
- Vol. 109 (1)
Ultrahigh‐temperature field cooling poling of PMN–PT single crystals for enhanced material and transducer performance
Relaxor‐based ferroelectric single crystals, such as Pb(Mg 1/3 Nb 2/3 )O 3 –PbTiO 3 (PMN–PT), are critical for advanced ultrasonic transducers due to their exceptional piezoelectric and electromechanical properties. To further enhance performance, domain engineering has emerged as a cost‐effective and versatile strategy for tailoring material functionality. In this work, an ultrahigh‐temperature field cooling poling (UFCP) method is applied to [001]‐oriented PMN–PT single crystals. The approach combines DC–AC poling above the Curie temperature with a subsequent field cooling process, enabling controlled domain configuration and enhanced thickness‐mode vibration performance. Compared with conventional direct current poling (DCP), UFCP crystals exhibit a 51% increase in piezoelectric coefficient and a 23% improvement in the mechanical quality factor . Thickness‐mode ultrasonic transducers fabricated from these crystals further demonstrate a 7.2% enhancement in −6 dB bandwidth and a 2.3 dB reduction in insertion loss. These results establish UFCP as an effective domain engineering strategy that optimizes phase coexistence to achieve simultaneous improvements in material properties and device performance.
- 21 January 2026
- Published by Wiley in Journal of the American Ceramic Society
- Vol. 109 (1)
Ultrahigh‐temperature field cooling poling of PMN–PT single crystals for enhanced material and transducer performance
Relaxor‐based ferroelectric single crystals, such as Pb(Mg 1/3 Nb 2/3 )O 3 –PbTiO 3 (PMN–PT), are critical for advanced ultrasonic transducers due to their exceptional piezoelectric and electromechanical properties. To further enhance performance, domain engineering has emerged as a cost‐effective and versatile strategy for tailoring material functionality. In this work, an ultrahigh‐temperature field cooling poling (UFCP) method is applied to [001]‐oriented PMN–PT single crystals. The approach combines DC–AC poling above the Curie temperature with a subsequent field cooling process, enabling controlled domain configuration and enhanced thickness‐mode vibration performance. Compared with conventional direct current poling (DCP), UFCP crystals exhibit a 51% increase in piezoelectric coefficient and a 23% improvement in the mechanical quality factor . Thickness‐mode ultrasonic transducers fabricated from these crystals further demonstrate a 7.2% enhancement in −6 dB bandwidth and a 2.3 dB reduction in insertion loss. These results establish UFCP as an effective domain engineering strategy that optimizes phase coexistence to achieve simultaneous improvements in material properties and device performance.
- Open Access
High-Sensitivity Air-Coupled Ultrasonic Transducer Design Based on PMN-PT Bending Vibration Modes
Gas pipelines are a critical means of transportation in industrial production. To detect gas pipeline leaks, ultrasonic transducers with specific center frequencies and high sensitivity are required. This paper proposes a novel air-coupled ultrasonic transducer design based on a horn-type matching layer and a bending-mode type of piezoelectric material, specifically tailored for gas leak detection scenarios. The transducer design is optimized by the finite element method, focusing on the basic components of the piezoelectric bimorph, the horn and the supporting tube. First, the influence of various dimensional parameters of the piezoelectric bimorph on the bending vibration mode was analyzed. Then, the effects of the other two components, the horn and the supporting tube, on the piezoelectric bimorph vibration mode were investigated. A parametric scan on the dimensions of these components was conducted to optimize the transducer’s output. Finally, ultrasonic transducers using PMN-PT and PZT were fabricated and tested. The results show that the sensitivity of those transducers surpasses that of similar commercial transducers, especially the PMN-PT one with a center frequency of 40 kHz and a peak receiving sensitivity of −51.1 dB. This transducer, benefiting from the high-performance piezoelectric material and the bending vibration mode, proves to be a promising candidate for high-precision leak detection in gas pipelines.
Open AccessHigh-Sensitivity Air-Coupled Ultrasonic Transducer Design Based on PMN-PT Bending Vibration Modes
Gas pipelines are a critical means of transportation in industrial production. To detect gas pipeline leaks, ultrasonic transducers with specific center frequencies and high sensitivity are required. This paper proposes a novel air-coupled ultrasonic transducer design based on a horn-type matching layer and a bending-mode type of piezoelectric material, specifically tailored for gas leak detection scenarios. The transducer design is optimized by the finite element method, focusing on the basic components of the piezoelectric bimorph, the horn and the supporting tube. First, the influence of various dimensional parameters of the piezoelectric bimorph on the bending vibration mode was analyzed. Then, the effects of the other two components, the horn and the supporting tube, on the piezoelectric bimorph vibration mode were investigated. A parametric scan on the dimensions of these components was conducted to optimize the transducer’s output. Finally, ultrasonic transducers using PMN-PT and PZT were fabricated and tested. The results show that the sensitivity of those transducers surpasses that of similar commercial transducers, especially the PMN-PT one with a center frequency of 40 kHz and a peak receiving sensitivity of −51.1 dB. This transducer, benefiting from the high-performance piezoelectric material and the bending vibration mode, proves to be a promising candidate for high-precision leak detection in gas pipelines.
- Open Access
Optimizing High-Power Performance of [001]-Oriented Pb(Mg1/3Nb2/3)-PbTiO3 Through Combined DC and AC Polarization Above Curie Temperature
Pb(Mg1/3Nb2/3)O3-PbTiO3 single crystals (PMN-PT SCs) are widely utilized in high-performance piezoelectric devices due to their exceptional piezoelectric properties. Among the various post-processing techniques for domain engineering in PMN-PT SCs, alternating current polarization (ACP) has become a widely adopted method for enhancing piezoelectric performance. This study proposes a new ultrahigh-temperature field-cooling polarization (UFCP) technique, combining direct current polarization (DCP) and ACP with field cooling above the Curie temperature. Dielectric spectra indicate that the UFCP method promotes electric field-induced phase transitions above the Curie point, forming a stable multiphase configuration. The transverse piezoelectric coefficient of UFCP SCs is , and the electromechanical coupling factor is 0.559. Compared with traditional DCP, UFCP increases by 68.6%, the mechanical quality factor by 16.7%, and the piezoelectric figure of merit (FOM) by 98.3%. Furthermore, under high-power excitation with a root-mean-square voltage of , UFCP achieves a 343% increase in power and a 130.5% improvement in the FOM compared with DCP, demonstrating its potential for enhancing high-power performance in practical applications.Open AccessOptimizing High-Power Performance of [001]-Oriented Pb(Mg1/3Nb2/3)-PbTiO3 Through Combined DC and AC Polarization Above Curie Temperature
Pb(Mg1/3Nb2/3)O3-PbTiO3 single crystals (PMN-PT SCs) are widely utilized in high-performance piezoelectric devices due to their exceptional piezoelectric properties. Among the various post-processing techniques for domain engineering in PMN-PT SCs, alternating current polarization (ACP) has become a widely adopted method for enhancing piezoelectric performance. This study proposes a new ultrahigh-temperature field-cooling polarization (UFCP) technique, combining direct current polarization (DCP) and ACP with field cooling above the Curie temperature. Dielectric spectra indicate that the UFCP method promotes electric field-induced phase transitions above the Curie point, forming a stable multiphase configuration. The transverse piezoelectric coefficient of UFCP SCs is , and the electromechanical coupling factor is 0.559. Compared with traditional DCP, UFCP increases by 68.6%, the mechanical quality factor by 16.7%, and the piezoelectric figure of merit (FOM) by 98.3%. Furthermore, under high-power excitation with a root-mean-square voltage of , UFCP achieves a 343% increase in power and a 130.5% improvement in the FOM compared with DCP, demonstrating its potential for enhancing high-power performance in practical applications. - Open Access
Studies on the High-Power Piezoelectric Property Measurement Methods and Decoupling the Power and Temperature Effects on PZT-5H
For those piezoelectric materials that operate under high-power conditions, the piezoelectric and dielectric properties obtained under small signal conditions cannot be directly applied to high-power transducers. There are three mainstream high-power characterization methods: the constant voltage method, the constant current method, and the transient method. In this study, we developed and verified a combined impedance method that integrated the advantages of the constant voltage and current methods, along with an improved transient method, for high-power testing of PZT-5H piezoelectric ceramics. The results from both methods indicated that with increasing power, the electromechanical coupling coefficient , the piezoelectric constant , and the elastic compliance of the PZT-5H showed increasing trends, while the mechanical quality factor first decayed rapidly and then stabilized at a fixed level. Additionally, under the combined impedance method, the temperature of the vibrators rose significantly due to self-heating, whereas the transient method generated almost no heat, and the vibrators remained at room temperature. By comparing the results from the two methods, we decoupled the effects of temperature and power on the high-power piezoelectric performance. The results showed that the self-heating temperature amplified the effects of power on , , and , while its influence on remained negligible.Open AccessStudies on the High-Power Piezoelectric Property Measurement Methods and Decoupling the Power and Temperature Effects on PZT-5H
For those piezoelectric materials that operate under high-power conditions, the piezoelectric and dielectric properties obtained under small signal conditions cannot be directly applied to high-power transducers. There are three mainstream high-power characterization methods: the constant voltage method, the constant current method, and the transient method. In this study, we developed and verified a combined impedance method that integrated the advantages of the constant voltage and current methods, along with an improved transient method, for high-power testing of PZT-5H piezoelectric ceramics. The results from both methods indicated that with increasing power, the electromechanical coupling coefficient , the piezoelectric constant , and the elastic compliance of the PZT-5H showed increasing trends, while the mechanical quality factor first decayed rapidly and then stabilized at a fixed level. Additionally, under the combined impedance method, the temperature of the vibrators rose significantly due to self-heating, whereas the transient method generated almost no heat, and the vibrators remained at room temperature. By comparing the results from the two methods, we decoupled the effects of temperature and power on the high-power piezoelectric performance. The results showed that the self-heating temperature amplified the effects of power on , , and , while its influence on remained negligible. - 25 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (4) , 7095-7106
A Piezoelectric–Piezoresistive Coupled Electric Field Sensor for Large Dynamic Range Measurement From DC to 1.5 kHz
The electric field intensity is a critical parameter in electrical power systems, providing significant insights into the system’s condition. Electric field sensors (E-sensors) are essential for monitoring variations in electric field strength. The current challenge facing E-sensors is to achieve the detection of DC electric fields while ensuring a wide dynamic range of field strengths. This paper proposes a novel E-sensor that combines piezoelectric and piezoresistive (PE-PR) elements in its sensitive structure. This paper proposes a novel E-sensor that combines piezoelectric and piezoresistive (PE-PR) elements in its sensitive structure. Shielding plates are positioned on both the upper and lower sides of the PE-PR sensitive element. The conductive states of the two shield plates are controlled through a switching circuit, enabling the modulation and testing of DC electric fields. This design overcomes the incompatibility between DC electric field testing and a wide dynamic range of electric field strengths in E-sensors. This passive sensor can perform electric field measurements within a DC-1.5 kHz bandwidth from 0 to 150 kV/m, with linearity of less than 0.92 %, a field resolution up to 50 V/m, sensitivity reaching 1.06 mV/kV/m (@ 1500 Hz), 128 mV/kV/m (@ DC), and hysteresis error less than 2%. The specifications can be customized according to requirements. Compared to existing research, this electric field sensor meets basic measurement requirements and offers the advantages of a simplified fabrication process and smaller dimensions. The relatively small sensor allows for integration into most power electrical equipment.
- 25 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (4) , 7095-7106
A Piezoelectric–Piezoresistive Coupled Electric Field Sensor for Large Dynamic Range Measurement From DC to 1.5 kHz
The electric field intensity is a critical parameter in electrical power systems, providing significant insights into the system’s condition. Electric field sensors (E-sensors) are essential for monitoring variations in electric field strength. The current challenge facing E-sensors is to achieve the detection of DC electric fields while ensuring a wide dynamic range of field strengths. This paper proposes a novel E-sensor that combines piezoelectric and piezoresistive (PE-PR) elements in its sensitive structure. This paper proposes a novel E-sensor that combines piezoelectric and piezoresistive (PE-PR) elements in its sensitive structure. Shielding plates are positioned on both the upper and lower sides of the PE-PR sensitive element. The conductive states of the two shield plates are controlled through a switching circuit, enabling the modulation and testing of DC electric fields. This design overcomes the incompatibility between DC electric field testing and a wide dynamic range of electric field strengths in E-sensors. This passive sensor can perform electric field measurements within a DC-1.5 kHz bandwidth from 0 to 150 kV/m, with linearity of less than 0.92 %, a field resolution up to 50 V/m, sensitivity reaching 1.06 mV/kV/m (@ 1500 Hz), 128 mV/kV/m (@ DC), and hysteresis error less than 2%. The specifications can be customized according to requirements. Compared to existing research, this electric field sensor meets basic measurement requirements and offers the advantages of a simplified fabrication process and smaller dimensions. The relatively small sensor allows for integration into most power electrical equipment.