Kyung-Eun Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Kyung-Eun Kim has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jongbin Kim
Department of Pediatric Dentistry, College of Dentistry, Dankook University, Cheonan, Republic of Korea
2 shared publications - Jisun Shin
Department of Pediatric Dentistry, College of Dentistry, Dankook University, Cheonan, Republic of Korea
1 shared publication - Joonhaeng Lee
Department of Pediatric Dentistry, College of Dentistry, Dankook University, Cheonan, Republic of Korea
1 shared publication - Miran Han
Department of Pediatric Dentistry, College of Dentistry, Dankook University, Cheonan, Republic of Korea
1 shared publication - Sooil Shin
Department of Advanced General Dentistry, Dankook University College of Dentistry, Cheonan, Republic of Korea
1 shared publication - Yu-Jin Kim
Department of Biomaterials Science, College of Dentistry, Dankook University, Cheonan, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 30 November 2026
- Published by Korean Academy of Pediatric Dentistry in THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY
- Vol. 53 (4) , 462-475
Depth-Dependent Microhardness and Primary Molar Dentin Bond Strength of a Self-Cured Bulk-Fill Composite
This study evaluated how the polymerization mechanism affects depth-dependent microhardness and shear bond strength to primary molar dentin. Three materials were tested: a conventional light-cured flowable composite, a light-cured bulk-fill composite and a self-cured bulk-fill composite. Each material was placed as a single increment, and Vickers microhardness was measured at 2.0, 3.0, and 4.0 mm (n = 10 per group). For shear bond strength testing, forty primary molars were assigned to four bonding groups (n = 10): the two light-cured composites were bonded with a universal adhesive, and the self-cured composite with either the universal adhesive combined with a dual cure activator or its dedicated primer. The interaction between material and depth was significant: microhardness decreased substantially with depth in the conventional composite, whereas the decrease was smaller in both bulk-fill materials and did not differ between them. Shear bond strength differed significantly among the groups (p < 0.0001), being highest in the self-cured composite with its dedicated primer (median 20.4 MPa) and lowest for the conventional composite (8.9 MPa), while the light-cured bulk-fill composite and the self-cured composite with the universal adhesive did not differ. Within the limitations of this study, the microhardness of the self-cured composite appeared less dependent on depth than that of the conventional composite and comparable with that of the lightcured bulk-fill composite, and its bond strength depended on the adhesive system used. This material may be of interest for restorations of primary molars in which light delivery is limited.
- 30 November 2026
- Published by Korean Academy of Pediatric Dentistry in THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY
- Vol. 53 (4) , 462-475
Open AccessDepth-Dependent Microhardness and Primary Molar Dentin Bond Strength of a Self-Cured Bulk-Fill Composite
This study evaluated how the polymerization mechanism affects depth-dependent microhardness and shear bond strength to primary molar dentin. Three materials were tested: a conventional light-cured flowable composite, a light-cured bulk-fill composite and a self-cured bulk-fill composite. Each material was placed as a single increment, and Vickers microhardness was measured at 2.0, 3.0, and 4.0 mm (n = 10 per group). For shear bond strength testing, forty primary molars were assigned to four bonding groups (n = 10): the two light-cured composites were bonded with a universal adhesive, and the self-cured composite with either the universal adhesive combined with a dual cure activator or its dedicated primer. The interaction between material and depth was significant: microhardness decreased substantially with depth in the conventional composite, whereas the decrease was smaller in both bulk-fill materials and did not differ between them. Shear bond strength differed significantly among the groups (p < 0.0001), being highest in the self-cured composite with its dedicated primer (median 20.4 MPa) and lowest for the conventional composite (8.9 MPa), while the light-cured bulk-fill composite and the self-cured composite with the universal adhesive did not differ. Within the limitations of this study, the microhardness of the self-cured composite appeared less dependent on depth than that of the conventional composite and comparable with that of the lightcured bulk-fill composite, and its bond strength depended on the adhesive system used. This material may be of interest for restorations of primary molars in which light delivery is limited.
- Open Access
- 31 December 2024
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 20 (4) , 181-185
Effectiveness of a Novel Oral Irrigator in Removing Artificial Dental Plaque on the Buccal and Lingual Surfaces of Preformed Metal Crowns
Kyung-Eun Kim, Jong-Bin Kim, Soo-Il Shin. IJCPD 2024;20:181-5. https://doi.org/10.15236/ijcpd.2024.20.4.181
- 31 December 2024
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 20 (4) , 181-185
Open AccessEffectiveness of a Novel Oral Irrigator in Removing Artificial Dental Plaque on the Buccal and Lingual Surfaces of Preformed Metal Crowns
Kyung-Eun Kim, Jong-Bin Kim, Soo-Il Shin. IJCPD 2024;20:181-5. https://doi.org/10.15236/ijcpd.2024.20.4.181