Chaowen Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Chaowen Wu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Changcheng Shi
Zhejiang International Scientific and Technological Cooperative Base of Biomedical Materials and Technology Zhejiang Engineering Research Center for Biomedical Materials Laboratory of Advanced Theranostic Materials and Technology Ningbo Institute of Materials Technology and Engineering Chinese Academy of Sciences Ningbo People's Republic of China
1 shared publication Fengbing Zhang
Ningbo Rehabilitation Hospital, Ningbo, Zhejiang, China
1 shared publication- Guohong Chai
Laboratory of Advanced Theranostic Materials and Technology, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, China
1 shared publication - Guokun Zuo
Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang, China
1 shared publication - Hao Chen
Cixi Biomedical Research Institute, Wenzhou Medical University, Ningbo, Zhejiang, China
1 shared publication - Jiajia Wu
Cixi Biomedical Research Institute, Wenzhou Medical University, Ningbo, Zhejiang, China
1 shared publication
Latest Publications
- 5 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (18) , 29258-29270
A Modified Method of Wearable Gait Analysis for Stroke Patients Based on the Peak Width Threshold and Phase Re-Segmentation
Wearable gait analysis technology offering flexibility and cost-effectiveness, holds significant potential for quantifying the gait functions of stroke patients. It remains a key challenge that how to further reduce cumulative errors by using wearable technology. An algorithm for re-segmenting the gait phase was proposed to improve the precision of zero-velocity detection and gait parameters. The adaptive threshold method was used to separate the stationary phase and the non-stationary phase of the gait cycle. Next, an efficient method called the peak width threshold (PWT) for phase re-segmentation was developed to obtain effective peaks from acceleration and angular velocity data. And the peaks which were incorrectly segmented would be adjusted between the stationary and non-stationary phase. The precision of feet position detection was improved by using zero velocity update (ZUPT) algorithm and dual-foot constraints. Finally, four typical gait parameters were calculated from feet position and phase information. The results demonstrated that the wearable inertial sensors system displays a good agreement compared to the foot pressure-based gait analysis system, and the mean absolute errors (MAE) of the stride length, step length, stride velocity, and cadence are 1.77±1.22 cm, 2.40±1.83 cm, 0.02±0.01 m/s, and 1.16±1.37 steps/min, respectively. This proposed method improves the accuracy of gait phase and feet position detection, which is helpful to objectively evaluate the gait functions of stroke patients.
- 5 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (18) , 29258-29270
A Modified Method of Wearable Gait Analysis for Stroke Patients Based on the Peak Width Threshold and Phase Re-Segmentation
Wearable gait analysis technology offering flexibility and cost-effectiveness, holds significant potential for quantifying the gait functions of stroke patients. It remains a key challenge that how to further reduce cumulative errors by using wearable technology. An algorithm for re-segmenting the gait phase was proposed to improve the precision of zero-velocity detection and gait parameters. The adaptive threshold method was used to separate the stationary phase and the non-stationary phase of the gait cycle. Next, an efficient method called the peak width threshold (PWT) for phase re-segmentation was developed to obtain effective peaks from acceleration and angular velocity data. And the peaks which were incorrectly segmented would be adjusted between the stationary and non-stationary phase. The precision of feet position detection was improved by using zero velocity update (ZUPT) algorithm and dual-foot constraints. Finally, four typical gait parameters were calculated from feet position and phase information. The results demonstrated that the wearable inertial sensors system displays a good agreement compared to the foot pressure-based gait analysis system, and the mean absolute errors (MAE) of the stride length, step length, stride velocity, and cadence are 1.77±1.22 cm, 2.40±1.83 cm, 0.02±0.01 m/s, and 1.16±1.37 steps/min, respectively. This proposed method improves the accuracy of gait phase and feet position detection, which is helpful to objectively evaluate the gait functions of stroke patients.