MPMohammad Paurobally

Mohammad Paurobally

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohammad Paurobally has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Vibroacoustic sensitivity of an oud soundboard to bracing geometry

    by Mohamed Abdallah, Elias Dreik, Amine Sassi, Mohammad Paurobally, Sadok Sassi

    This study examines how internal bracing geometry influences the vibro-acoustic behavior of the oud soundboard. A three-dimensional finite element model of the instrument was developed and experimentally validated through impact-hammer modal testing. Fourteen bracing configurations, ranging from traditional ladder layouts to alternative geometries, were analyzed under identical material and boundary conditions. Structural response, modal characteristics, and acoustic radiation were evaluated using a coupled structural–acoustic simulation framework. To enable systematic comparison, six quantitative performance indicators were introduced to represent vibrational stiffness, stress distribution, acoustic radiation, structural–acoustic efficiency, modal balance, and overall acoustic effectiveness. The results show that bracing strongly governs the stiffness distribution, thereby shifting the modal spectrum and the soundboard’s radiation behavior. Increased bracing density raises low-order modal frequencies and enhances projection and spectral clarity, whereas reduced bracing favors stronger low-frequency motion and increased low-frequency content, but yields a less controlled response. No single configuration maximizes all criteria simultaneously; instead, each layout represents a distinct trade-off among tonal richness, projection, and mechanical robustness. Two sets of design targets were defined to reflect different performance priorities, enabling configurations to be ranked for either tonal uniformity or acoustic power. Among the tested layouts, two configurations consistently delivered the best combined structural and acoustic performance across both target sets. Sensitivity analysis confirmed that these rankings are robust to moderate variations in the evaluation thresholds.


  • Open Access

    Performance Comparison of Hybrid and Standalone Piezoelectric Energy Harvesters Under Vortex-Induced Vibrations

    by Issam Bahadur, Hassen Ouakad, El Manaa Barhoumi, Asan Muthalif, Muhammad Hafizh, Jamil Renno, Mohammad Paurobally

    This study investigates the effect of incorporating an electromagnetic harvester inside the bluff body of a 2-DoF hybrid harvester in comparison to a standalone piezoelectric harvester for various external loads. The harvester is excited through a vortex-induced vibration owing to the resultant wake vortices created behind the bluff body. The coupled dynamics of the two harvester components are modeled, and numerical simulations are conducted to evaluate the system’s performance under varying electrical loads. Numerical results show that at high, optimum electrical load, the standalone piezoelectric harvester outperforms the hybrid harvester. Nevertheless, for small electrical loads, the results show that the hybrid harvester outperforms the standalone PZT harvester by up to 18% in peak power output, while reducing the bandwidth by approximately 10% compared to the standalone piezoelectric harvester. Optimal spring stiffness values were identified, with the hybrid harvester achieving its maximum output power at a spring stiffness of 83.56 N/m. These findings underscore the need for careful design considerations, as the hybrid harvester may not achieve enhanced power output and bandwidth under higher electrical loads.


  • Open Access

    Comparative Study of a 2-DoF Hybrid Piezoelectric-Electromagnetic Energy Harvester and a Standalone Piezoelectric Harvester

    by Issam M. Bahadur, Hassen Ouakad, El Manaa Barhoumi, Asan Muthalif, Muhammad Hafizh, Jamil Renno, Mohammad Paurobally

    This study investigates the effect of incorporating an electromagnetic harvester inside the bluff body of a 2-DoF hybrid harvester in comparison to a standalone piezoelectric harvester for various external loads. The design consists of an electromagnetic harvester embedded inside a cylindrical bluff body, which is attached to the free end of a composite PZT cantilever beam. The harvester is excited through a vortex-induced vibration owing to the resultant wake vortices created behind the bluff body. The coupled equations of motion of the harvester are derived using the lumped-mass equivalent representation and Lagrange formulation. Numerical results show that at high operating flow speed and large electrical load, the standalone piezoelectric harvester outperforms the hybrid harvester. Nevertheless, for small electrical loads and at low-speed flow, the hybrid harvester outperforms the standalone ones for a wider range of the flow speed. In these operating conditions, numerical simulations also showed that an optimum spring stiffness of the electromagnetic harvester exists at a certain flow speed for a maximized harvested output power. In general, such hybrid energy harvester showed to be more effective at low-speed fluid flow and small electrical loads.


  • Open Access

    Energy Benefits of PV-Integrated Dynamic Overhangs for Residential Buildings in Qatar

    by Moncef Krarti, Mohamed A. Ayari, Farid Touati, Mohammad R. Paurobally

    This paper summarizes the potential energy efficiency benefits of PV-integrated dynamic overhangs for housing units in Qatar. Specifically, the technology combines two energy benefits of shading effects of reducing air conditioning loads and generating on-site electricity generation. The analysis is performed for a prototypical dwelling unit in Doha, Qatar. Three adjustment frequencies for the positions of the PV-integrated dynamic overhangs are evaluated, including hourly, daily, and monthly. It is found that optimally operated PV-integrated overhangs can substantially reduce the annual electricity needs of the dwelling unit. For instance, southern-oriented PV-integrated dynamic overhangs can lower the annual net energy requirements for the dwelling unit by 69.7% relative to the case with no shading and by 32.2% relative to the case of deploying PV-integrated static overhangs. Higher energy use reductions can be achieved when the overhang depth and window size are increased and when more energy-efficient glazing types are installed.