OBOlena Borsuk

Olena Borsuk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Olena Borsuk has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Study of fire hazards in electrical connections of various types

    by Yaroslav Kalchenko, Volodymyr Oliinyk, Olena Borsuk, Olesia Kostyrka, Ilya Kirichenko

    Studies have been conducted to determine the temperature of electric lamps of various types in emergency modes of operation of power grids, namely overvoltage. Graphs of the dependence of the temperature of the bulb of incandescent lamps, arc mercury lamps and LED lamps on the voltage applied to them. Mathematical models of the value of the heating temperature of the bulb of the electric incandescent lamp, the arc mercury lamp and the LED lamp are obtained depending on the time. It is determined that the temperature of the bulb of the incandescent electric lamp increases exponentially and stabilizes after about 300 seconds. The temperature of an arc mercury lamp also varies exponentially, but, compared to an incandescent lamp, it is not so fast, but stabilizes after about 600 seconds. It is determined that in emergency modes of operation, the temperature of incandescent lamps and arc mercury lamps may exceed the normative values of temperature groups, as a result of which, when used in environments where explosive gases or vapors are present, they can become a source of ignition and lead to explosion or ignition of these substances. It is determined that the temperature of the LED lamp changes according to the linear law and after 300 seconds stops growing. Temperature dependencies of different elements of the LED lamp are built depending on the electric voltage applied to it. It was found that the driver, namely the power control chip, heats up most when the LED electric lamp is operating. It is determined that when the electric voltage decreases, the power control chip heats up more, but not significantly. It was found that the LED lamp is the best from the point of view of fire safety, since it has the lowest temperature, and also the change in the voltage of the electrical network reacts the least, which is explained by its design and principle of operation.

  • Determination of various types electric lamps parameters in emergency modes of operation

    by Yaroslav Kalchenko, Kostiantyn Afanasenko, Volodymyr Oliinyk, Olena Borsuk, Olesia Kostyrka

    Studies have been conducted to determine the temperature of electric lamps of various types in emergency modes of operation of power grids, namely overvoltage. Graphs of the dependence of the temperature of the bulb of incandescent lamps, arc mercury lamps and LED lamps on the voltage applied to them. Mathematical models of the value of the heating temperature of the bulb of the electric incandescent lamp, the arc mercury lamp and the LED lamp are obtained depending on the time. It is determined that the temperature of the bulb of the incandescent electric lamp increases exponentially and stabilizes after about 300 seconds. The temperature of an arc mercury lamp also varies exponentially, but, compared to an incandescent lamp, it is not so fast, but stabilizes after about 600 seconds. It is determined that in emergency modes of operation, the temperature of incandescent lamps and arc mercury lamps may exceed the normative values of temperature groups, as a result of which, when used in environments where explosive gases or vapors are present, they can become a source of ignition and lead to explosion or ignition of these substances. It is determined that the temperature of the LED lamp changes according to the linear law and after 300 seconds stops growing. Temperature dependencies of different elements of the LED lamp are built depending on the electric voltage applied to it. It was found that the driver, namely the power control chip, heats up most when the LED electric lamp is operating. It is determined that when the electric voltage decreases, the power control chip heats up more, but not significantly. It was found that the LED lamp is the best from the point of view of fire safety, since it has the lowest temperature, and also the change in the voltage of the electrical network reacts the least, which is explained by its design and principle of operation.

  • Open Access

    Establishing the effect of low-percentage doses of foaming agents on increasing fluid consumption at its transportation by fire hoses

    by Serhiy Stas, Denis Kolesnikov, Artem Bychenko, Olena Borsuk

    In the cases where there is a need to quickly move large volumes of water over a distance of hundreds of meters, firefighting equipment is used. In such cases, hose lines formed from fire hoses are usually used. An attempt was made to determine the effect of microdoses of foaming agents on the level of fluid consumption transported by fire hoses. It has been experimentally established that the fluid consumption during its transportation by fire hoses increased when foaming agents were added to it. The foaming agents Pirena-1, Sofir, Alpen, and Bars, which are used in firefighting in Ukraine, were selected for the experiments. Each of the foaming agents was used in two versions – one that meets and one that does not meet the guaranteed shelf life. The maximum increase in flow rate (11.5 %) was recorded when adding 0.021 % of the Bars foaming agent to water. The results of the experiments depended on the brand of foaming agents used and were almost independent of the “age” of the foaming agents. It is important that the results of the study showed that “overdue” foaming agents can be used to increase the efficiency of fire-fighting equipment. Latex-coated pressure fire hoses with a diameter of 51 mm were randomly selected (from those available in the fire department). The length of the hose line was 200 m (500 m for hoses with a diameter of 77 mm), the ambient temperature was about 20 °C, the pressure at the pump was 4…6 bar. The facts of the increase in liquid flow rate established in the study could be used in practice to increase the amount of liquid transportation (pumping) without changing other parameters of the fire-fighting equipment, for example, when eliminating the consequences of floods or landslides


  • Open Access

    RESEARCH OF THEFIRE RESISTANCE OF REINFORCED CONCRETE HOLLOW CORE SLAB

    by Cherkassy Institute of Fire Safety Named after Chernobyl Heroes ofNational University of Civil Defense of Ukraine, Serhii Pozdieiev, Stanislav Sidnei, Ольга Некора, Iryna Rudeshko, Andriy Berezovskyi, Ivan Shchenko, Сергій Поздєєв, Станіслав Сідней, Ірина Рудешко, et al.

    The paper presents the results of evaluating the fire resistance of a reinforced concrete hollow slab using a refined method using the finite element method. The purpose of the work is to determine which limit state of fire resistance of the considered reinforced concrete hollow slab occurs first under the influence of thestandard fire temperature regime. The creation of mathematical models of concrete and reinforcement materials was carried out taking into account the recommendations of Eurocode 2. Symmetry was used to reduce resource provision during calculations. A finite-element mesh of the studied reinforced concrete hollow slab was created using finite elements of the following types: SOLID186, CONTAL174, SURF154 and REINF264. Computational experiments were carried out in two stages, in the first stage a thermal engineering problem was solved, in the second stage a static calculation was conducted to assess the fire resistance of a reinforced concrete hollow slab. The calculations were carried out according to the specified method recommended by Eurocode 2 in the thermal and mechanical modules of the AYSYS WB software complex. In order to obtain the most reliable results of the behavior of the studied reinforced concrete hollow slab during the study of the results of the stress-strain state, hinged resting on the stand is provided.The obtained results indicate that the onset of the limit state for the loss of entiretyoccurs earlier than for the loss of bearing capacity at 678 s, which poses threats to the life and health of people before the occurrence of critical deflection due to the penetration of smoke, toxic products of combustion and temperature through the cracks formed in the structure . Loss of heat-insulating ability at the time of loss of entiretywas also not observed. According to the results of computational experiments, it was established that the fire resistance limit of the investigated reinforced concrete hollow slab is 40.83 min and does not correspond to the REI 45 fire resistance class under the condition of its load of 4 kPa

  • Open Access

    STUDY OF THE FIRE RESISTANCE OF A REINFORCED CONCRETE SLAB

    by Cherkasy Institute of Fire Safety of National University of Civil Protectionof Ukraine, Stanislav Sidnei, Ольга Некора, Iryna Rudeshko, Andriy Berezovskyi, Tetiana Kostenko, Ivan Ishchenko, Станіслав Сідней, Ірина Рудешко, Андрій Березовський, et al.

    The work presents an algorithm for carrying out a refined method of calculating the fire resistance of a reinforced concrete ribbed slab modeled according to the design type PR 63-15 when using the finite element method. The parameters of the Drucker–Prager theory of concrete strength were used in the calculations. The finite-element model consisted of more than 13,000 finite elements of hexahedral shape.To solve the thermal problem, the thermophysical characteristics of concrete and steel reinforcement were used, which correspond to the temperature dependences recommended by the second part of Eurocode 2. To reproduce the heat exchange during the influence of the standard temperature regime of the fire, an unsteady two-dimensional quasi-linear equation of thermal conductivity is used, assuming that the stress-strain state does not affect the temperature distribution. Boundary conditions of the IIIrd kind are given, which is also recommended for the second part of Eurocode 2. The results of the temperature distribution in the simulated reinforced concrete ribbed slab during 60 min are obtained. The temperature indicators were used in solving the compatible thermomechanical problem of evaluating the fire resistance of the studied reinforced concrete ribbed slab at 50%, 70% and 100% load level from the maximum. The fire resistance of the board was evaluated according to the limit state of the loss of load-bearing capacity (R) without taking into account the formation of cracks or through defects. The maximum stresses in the concrete of the studied structure, which are formed during deformations at different load levels, are observed in the upper part of the longitudinal ribs and exceed 30 MPa, which is critical for concrete with such compressive strength.Based on the results of the research, a regularity was determined that establishes the relationship between fire resistance indicators and the level of applied mechanical load.

  • Research heating of the steel i-beam rods with mineral wool coating under the conditions of standard temperature fire regime

    by Cherkassy Institute of Fire Safety named after Chernobyl Heroes NUCP of Ukraine, S.V. Pozdieiev, O.M. Nuianzin, S.O. Sidnei, A.Y. Novhorodchenko, O.V. Borsuk

    In the article, experimental fire tests on establishing maximum fire resistance of the steel columns with fire-retardant mineral wool covering are analyzed. The scientific novelty of this study are the new method developed for manufacturing and shaping samples of the steel columns with fire-retardant mineral wool covering, and the method developed for conducting fire tests on establishing patterns of dependence of the moment when steel columns with the fire-retardant cladding lose their bearing capacity down to the limit. The subject of the study was an influence of design parameters of the fire-retardant cladding on the results of the estimated fire resistance of the steel columns under the influence of the standard fire temperature mode. The main task of the research described in this article was to determine a moment of the peak critical temperature of fire-retardant steel structure depending on the thickness of the mineral wool covering. The test results of samples of steel columns with different thickness of fire-retardant cladding based on mineral wool covering are also described in the article; the tests were carried out in accordance with the developed methodology of experimental studies. The repeatability of the time indicators of the bearing capacity loss by the tested samples of steel columns with fire-retardant cladding depending on the duration of the sample exposure to the action of the fire standard temperature is shown. The obtained research results will allow to create a mathematical model for predicting a dependence of the moment when a steel structure reaches its critical temperature depending on the thickness of the fire-retardant cladding. The constructed mathematical model can be considered as a scientific basis for the creation of new engineering methods of calculation for assessing fire resistance of the steel structures with fire-retardant mineral wool covering. These engineering and calculation methods allow improving the regulatory acts for designing of the fire-resistant steel structures.