Fabrizio Cacciari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fabrizio Cacciari has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Alessandra Cecconi
Laboratory of Environmental Engineering, Department of Civil Engineering and Computer Science Engineering, University of Rome Tor Vergata, Via del Politecnico 1, 00133 Rome, Italy
1 shared publication - Alessandro Oldani
Eni, Via G. Fauser 4, 28100 Novara, Italy
1 shared publication - Antonella Vecchio
Department for the Geological Survey of Italy, ISPRA (Istituto Superiore per la Protezione e la Ricerca Ambientale), Italian Institute for Environmental Protection and Research, 00144 Rome, Italy
1 shared publication - Camilla Lanari
Eni Rewind, Piazza M. Boldrini 1, 20097 San Donato Milanese, Italy
1 shared publication - Donatella Giacopetti
UNEM (Energy Union for Mobility), Piazzale L. Sturzo 31, 00144 Rome, Italy
1 shared publication - Federico Fuin
ARPAV (Veneto Region Environmental Protection Agency), Via Lissa 6, 30171 Mestre, Italy
1 shared publication
Latest Publications
- Open Access
- 26 April 2025
- Published by MDPI AG in Environments
- Vol. 12 (5) , 141
Field Comparison of Active and Passive Soil Gas Sampling Techniques for VOC Monitoring at Contaminated Sites
This study presented a comprehensive comparison of soil gas sampling methodologies to monitor volatile organic compounds (VOCs) at two industrial sites in northern Italy. Utilizing active sampling techniques, such as stainless-steel canisters, vacuum bottles, and sorbent tubes, alongside passive methods like low-density polyethylene (PE) membranes, sorbent pens, and Waterloo Membrane Samplers (WMS), the research examines their effectiveness under varied environmental conditions. Five field campaigns were conducted in two areas of the industrial sites characterized by BTEX and chlorinated solvent contamination. The results highlighted that active sampling, while expensive, provides real-time, high-resolution VOC concentration data, often outperforming passive methods for heavier compounds (e.g., hexachlorobutadiene). However, using the active systems in certain campaigns, challenges such as high soil humidity or atmospheric air infiltration were observed, resulting in an underestimation of the soil gas concentrations. Passive sampling systems demonstrated cost-effective, efficient alternatives, offering consistent spatial and temporal coverage. These methods showed alignment with active techniques for lighter compounds (e.g., TCE and BTEX) but faced limitations in sorbent saturation and equilibrium time for heavier VOCs (e.g., hexachlorobutadiene), requiring adjustments in exposure duration to enhance accuracy. PE samplers provided results comparable to active methods, especially for BTEX and TCE, while WMS and sorbent pens exhibited lower sensitivity for certain analytes. This underscores the importance of optimizing sampler configurations and deployment strategies. The findings emphasize the value of integrating active and passive approaches to achieve robust VOC assessments in heterogeneous subsurface environments.
- 26 April 2025
- Published by MDPI AG in Environments
- Vol. 12 (5) , 141
Open AccessField Comparison of Active and Passive Soil Gas Sampling Techniques for VOC Monitoring at Contaminated Sites
This study presented a comprehensive comparison of soil gas sampling methodologies to monitor volatile organic compounds (VOCs) at two industrial sites in northern Italy. Utilizing active sampling techniques, such as stainless-steel canisters, vacuum bottles, and sorbent tubes, alongside passive methods like low-density polyethylene (PE) membranes, sorbent pens, and Waterloo Membrane Samplers (WMS), the research examines their effectiveness under varied environmental conditions. Five field campaigns were conducted in two areas of the industrial sites characterized by BTEX and chlorinated solvent contamination. The results highlighted that active sampling, while expensive, provides real-time, high-resolution VOC concentration data, often outperforming passive methods for heavier compounds (e.g., hexachlorobutadiene). However, using the active systems in certain campaigns, challenges such as high soil humidity or atmospheric air infiltration were observed, resulting in an underestimation of the soil gas concentrations. Passive sampling systems demonstrated cost-effective, efficient alternatives, offering consistent spatial and temporal coverage. These methods showed alignment with active techniques for lighter compounds (e.g., TCE and BTEX) but faced limitations in sorbent saturation and equilibrium time for heavier VOCs (e.g., hexachlorobutadiene), requiring adjustments in exposure duration to enhance accuracy. PE samplers provided results comparable to active methods, especially for BTEX and TCE, while WMS and sorbent pens exhibited lower sensitivity for certain analytes. This underscores the importance of optimizing sampler configurations and deployment strategies. The findings emphasize the value of integrating active and passive approaches to achieve robust VOC assessments in heterogeneous subsurface environments.