XWXuechun Wang

Xuechun Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xuechun Wang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Two-Stage Synergistic Compensation Method Regulates Disturbance Magnetic Field in MSC for High Quality MCG Measurement

    by Xuechun Wang, Haitao Li, Suhang Li, Haifeng Zhang, Yutong Wei, Fengwen Zhao, Runrun Yao

    Magnetocardiography (MCG) is critical for early diagnosis and treatment of cardiac diseases. Arrayed SERF atomic magnetometers deliver high-quality MCG in a near-zero field provided by a magnetic shielding cylinder (MSC) with active magnetic compensation (AMC). However, the magnetic noise within the MSC is dynamic and gradient-distributed, making conventional single-stage uniform-field AMC inadequate. To overcome this, we propose a two-stage synergistic compensation method. It flattens the gradient along the MSC opening axis in the first stage and nulls the noise along the SERF sensitivity axis at the second stage. The feedback-sensor positions are optimized by an NSGA-II based multiobjective algorithm, enhancing the noise suppression at each stage while preserving cardiac signals and avoids complex decoupling calculations. Experiments show that both the noise amplitude and spatial gradient on the measurement panel are reduced. In the presence of external disturbance, the magnetic field gradient decreased from 117.84 to 2.78 pT/m. The average sensitivity decreased from 238.19 fT/Hz1/2@1–40 Hz to 22.18 fT/Hz1/2@1–40 Hz, significantly improving the MCG signal quality.

  • Two-Stage Compensation System Based on Decoupled Biplanar Coils for Near-Zero Magnetic Field Environments

    by Haoan Wang, Yimin Chen, Haitao Li, Xuechun Wang, Ying Meng, Jinji Sun, Xikai Liu

    To achieve the near-zero magnetic field environment necessary for magnetoencephalography (MEG) measurements, a two-stage magnetic compensation (TMC) system for background magnetic field compensation in a magnetic shielding room (MSR) is proposed in this paper. The TMC system utilizes Decoupled Biplanar Coils (DBCs) to create two types of regions in MSR: uniform and decoupled regions. In the first stage, Helmholtz coil is arranged outside the MSR and a fluxgate for the measurement is placed in the decoupled region where the current in the DBC coil does not generate a magnetic field. Compensation in this stage can decrease residual magnetic field and guarantee optically pumped magnetometers (OPMs) function within the spin-exchange relaxation-free (SERF) regime. In the second stage, DBCs inside the MSR use OPMs for closed-loop feedback, generating spatially uniform magnetic fields. The TMC system effectively reduces residual and peak magnetic fields within the MSR, providing a suitable background magnetic field for magnetoencephalography (MEG) measurements.