Yourim Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yourim Kim has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Wonseuk Jang
Department of Medical Device Engineering and Management, Yonsei University College of Medicine, Seoul 06229, Republic of Korea
2 shared publications - Hyeonkyeong Choi
Department of Medical Device Engineering and Management, Yonsei University College of Medicine, Seoul 06229, Republic of Korea
1 shared publication - Jiyoon Oh
Department of Medical Device Engineering and Management, Yonsei University College of Medicine, Seoul 06229, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 16 March 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (6) , 2261
Usability Evaluation of a Central Monitoring System with AI-Based Cardiac Arrest Prediction in the ICU
Background/Objectives: The incidence of cardiac arrest among critically ill patients has been increasing, with many patients experiencing clinical exacerbation prior to the event. Early detection and rapid treatment are essential to reduce the risks associated with cardiac arrest; however, difficulties such as limited ICU resources and inadequate monitoring of vital signs reduce the effectiveness of treatment. Various cardiac arrest prediction systems have been developed to overcome these issues. This study performed a summative evaluation of a Central Monitoring System with AI-based Cardiac Arrest Prediction. Methods: A summative usability evaluation was conducted in a simulated ICU environment with 22 ICU nurses experienced in using patient monitoring devices. Participants completed tasks based on the device workflow and then filled out the System Usability Scale (SUS) and satisfaction surveys, with task performance and survey responses analyzed to assess usability. Results: The usability test achieved a task success rate of 90%, with critical tasks achieving success rates ranging from 73% to 100%. The SUS score was 67.3 (“OK”), and the satisfaction survey showed an average score of 4.5, indicating generally positive user perception. Conclusions: Participants generally rated the system as acceptable, although some tasks showed lower success rates due to design issues such as poor button visibility. Further studies in clinical settings are needed to evaluate the system’s effectiveness, user experience, and contribution to the timely detection of cardiac arrest.
- 16 March 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (6) , 2261
Open AccessUsability Evaluation of a Central Monitoring System with AI-Based Cardiac Arrest Prediction in the ICU
Background/Objectives: The incidence of cardiac arrest among critically ill patients has been increasing, with many patients experiencing clinical exacerbation prior to the event. Early detection and rapid treatment are essential to reduce the risks associated with cardiac arrest; however, difficulties such as limited ICU resources and inadequate monitoring of vital signs reduce the effectiveness of treatment. Various cardiac arrest prediction systems have been developed to overcome these issues. This study performed a summative evaluation of a Central Monitoring System with AI-based Cardiac Arrest Prediction. Methods: A summative usability evaluation was conducted in a simulated ICU environment with 22 ICU nurses experienced in using patient monitoring devices. Participants completed tasks based on the device workflow and then filled out the System Usability Scale (SUS) and satisfaction surveys, with task performance and survey responses analyzed to assess usability. Results: The usability test achieved a task success rate of 90%, with critical tasks achieving success rates ranging from 73% to 100%. The SUS score was 67.3 (“OK”), and the satisfaction survey showed an average score of 4.5, indicating generally positive user perception. Conclusions: Participants generally rated the system as acceptable, although some tasks showed lower success rates due to design issues such as poor button visibility. Further studies in clinical settings are needed to evaluate the system’s effectiveness, user experience, and contribution to the timely detection of cardiac arrest.
- Open Access
- 6 May 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (9) , 3218
Enhancing the Usability of Patient Monitoring Devices in Intensive Care Units: Usability Engineering Processes for Early Warning System (EWS) Evaluation and Design
Background/Objectives: This study aimed to enhance the usability of patient monitoring systems by integrating the Early Warning Score (EWS) function and improving user interface elements. The EWS function is expected to enable the early detection of acute deterioration and prompt medical intervention, while the optimized design supports rapid decision-making by nursing staff. Methods: Two formative usability evaluations were conducted to identify user requirements and improve the device design. A simulated usability test involved five ICU medical staff members, followed by a user preference survey with 72 ICU staff members in a real clinical setting. After incorporating feedback, a summative usability test with 23 ICU nurses was performed to evaluate the revised device. Results: Issues related to unfamiliar parameter terminology and alarm message positioning were identified, and the need for the EWS function was emphasized. The summative evaluation showed an increase in task success rate from 86% to 90% and a significant improvement in user satisfaction from 74.85 (SD: 0.88) to 89.55 (SD: 0.75) (p < 0.05). Conclusions: The integration of the EWS function and interface improvements significantly enhanced the usability of patient monitoring system. These advancements are expected to enable rapid detection of patient deterioration and support timely clinical decision-making by ICU staff.
- 6 May 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (9) , 3218
Open AccessEnhancing the Usability of Patient Monitoring Devices in Intensive Care Units: Usability Engineering Processes for Early Warning System (EWS) Evaluation and Design
Background/Objectives: This study aimed to enhance the usability of patient monitoring systems by integrating the Early Warning Score (EWS) function and improving user interface elements. The EWS function is expected to enable the early detection of acute deterioration and prompt medical intervention, while the optimized design supports rapid decision-making by nursing staff. Methods: Two formative usability evaluations were conducted to identify user requirements and improve the device design. A simulated usability test involved five ICU medical staff members, followed by a user preference survey with 72 ICU staff members in a real clinical setting. After incorporating feedback, a summative usability test with 23 ICU nurses was performed to evaluate the revised device. Results: Issues related to unfamiliar parameter terminology and alarm message positioning were identified, and the need for the EWS function was emphasized. The summative evaluation showed an increase in task success rate from 86% to 90% and a significant improvement in user satisfaction from 74.85 (SD: 0.88) to 89.55 (SD: 0.75) (p < 0.05). Conclusions: The integration of the EWS function and interface improvements significantly enhanced the usability of patient monitoring system. These advancements are expected to enable rapid detection of patient deterioration and support timely clinical decision-making by ICU staff.