NMNing Miao

Ning Miao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ning Miao has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Know Me by My Pulse: Toward Practical Continuous Authentication on Wearable Devices via Wrist-Worn PPG

    by Wei Shao, Zequan Liang, Ruoyu Zhang, Ruijie Fang, Ning Miao, Ehsan Kourkchi, Setareh Rafatirad, Houman Homayoun, Chongzhou Fang

    Biometric authentication using physiological signals offers a promising path toward secure and user-friendly access control in wearable devices. While electrocardiogram (ECG) signals have shown high discriminability, their intrusive sensing requirements and discontinuous acquisition limit practicality. Photoplethysmography (PPG), on the other hand, enables continuous, non-intrusive authentication with seamless integration into wrist-worn wearable devices. However, most prior work relies on high-frequency PPG (e.g., 75 - 500 Hz) and complex deep models, which incur significant energy and computational overhead, impeding deployment in power-constrained real-world systems. In this paper, we present the first real-world implementation and evaluation of a continuous authentication system on a smartwatch, We-Be Band, using low-frequency (25 Hz) multi-channel PPG signals. Our method employs a Bi-LSTM with attention mechanism to extract identity-specific features from short (4 s) windows of 4-channel PPG. Through extensive evaluations on both public datasets (PTTPPG) and our We-Be Dataset (26 subjects), we demonstrate strong classification performance with an average test accuracy of 88.11%, macro F1-score of 0.88, False Acceptance Rate (FAR) of 0.48%, False Rejection Rate (FRR) of 11.77%, and Equal Error Rate (EER) of 2.76%. Our 25 Hz system reduces sensor power consumption by 53% compared to 512 Hz and 19% compared to 128 Hz setups without compromising performance. We find that sampling at 25 Hz preserves authentication accuracy, whereas performance drops sharply at 20 Hz while offering only trivial additional power savings, underscoring 25 Hz as the practical lower bound. Additionally, we find that models trained exclusively on resting data fail under motion, while activity-diverse training improves robustness across physiological states.

  • Open Access

    Advanced Energy-Efficient System for Precision Electrodermal Activity Monitoring in Stress Detection

    by Ruoyu Zhang, Ruijie Fang, Elahe Hosseini, Chongzhou Fang, Ning Miao, Houman Homayoun

    This paper presents a novel Electrodermal Activity (EDA) signal acquisition system, designed to address the challenges of stress monitoring in contemporary society, where stress affects one in four individuals. Our system focuses on enhancing the accuracy and efficiency of EDA measurements, a reliable indicator of stress. Traditional EDA monitoring solutions often grapple with trade-offs between sensor placement, cost, and power consumption, leading to compromised data accuracy. Our innovative design incorporates an adaptive gain mechanism, catering to the broad dynamic range and high-resolution needs of EDA data analysis. The performance of our system was extensively tested through simulations and a custom Printed Circuit Board (PCB), achieving an error rate below 1\% and maintaining power consumption at a mere 700$μ$A under a 3.7V power supply. This research contributes significantly to the field of wearable health technology, offering a robust and efficient solution for long-term stress monitoring.

  • Open Access

    Side Channel-Assisted Inference Leakage from Machine Learning-based ECG Classification

    by Jialin Liu, Ning Miao, Chongzhou Fang, Houman Homayoun, Han Wang

    The Electrocardiogram (ECG) measures the electrical cardiac activity generated by the heart to detect abnormal heartbeat and heart attack. However, the irregular occurrence of the abnormalities demands continuous monitoring of heartbeats. Machine learning techniques are leveraged to automate the task to reduce labor work needed during monitoring. In recent years, many companies have launched products with ECG monitoring and irregular heartbeat alert. Among all classification algorithms, the time series-based algorithm dynamic time warping (DTW) is widely adopted to undertake the ECG classification task. Though progress has been achieved, the DTW-based ECG classification also brings a new attacking vector of leaking the patients' diagnosis results. This paper shows that the ECG input samples' labels can be stolen via a side-channel attack, Flush+Reload. In particular, we first identify the vulnerability of DTW for ECG classification, i.e., the correlation between warping path choice and prediction results. Then we implement an attack that leverages Flush+Reload to monitor the warping path selection with known ECG data and then build a predictor for constructing the relation between warping path selection and labels of input ECG samples. Based on experiments, we find that the Flush+Reload-based inference leakage can achieve an 84.0\% attacking success rate to identify the labels of the two samples in DTW.