Berk Can Açikgöz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Berk Can Açikgöz has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Bastien Milani
Institute of Systems Engineering, School of Engineering, HES-SO Valais-Wallis University of Applied Sciences and Arts Western Switzerland, Rue de l’industrie 23, Sion, Switzerland
1 shared publication - Benedetta Franceschiello
Institute of Systems Engineering, HES-SO Valais-Wallis University, Sion, Switzerland
1 shared publication - Dominik Helbing
Institute of Systems Engineering, School of Engineering, HES-SO Valais-Wallis University of Applied Sciences and Arts Western Switzerland, Rue de l’industrie 23, Sion, Switzerland
1 shared publication - Eva S. Peper
Department of Diagnostic, Interventional and Pediatric Radiology (DIPR) Inselspital, Bern University Hospital, University of Bern Bern Switzerland
1 shared publication - Jaime Barranco
CIBM Center for Biomedical Imaging, Lausanne, Switzerland
1 shared publication - Jean-Baptiste Ledoux
Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
1 shared publication
Latest Publications
- Open Access
Monalisa: an open source, documented MATLAB toolbox for magnetic resonance imaging reconstruction
Summary: Purpose: An open-source, user-friendly MATLAB framework for Magnetic Resonance Imaging (MRI) reconstruction was developed to simplify the reconstruction process, with a specific focus on non-Cartesian imaging and dynamic applications in the presence of motion. Methods: Monalisa is decomposing the reconstruction pipeline into clear modular steps, including raw data reading with flexible file-type abstraction, trajectory computation, density compensation, advanced coil sensitivity mapping, and tailored binning strategies through its “mitosius” preprocessing stage. The framework supports a suite of reconstruction methods, including iterative-SENSE (also named CG-SENSE), GeneRalized Autocalibrating Partial Parallel Acquisition (GRAPPA) reconstructions, and regularized reconstructions supporting both spatial and temporal regularization using l 1 (Compressed Sensing (CS)) and l 2 techniques, accommodating both Cartesian and non-Cartesian acquisitions. We performed benchmark experiments comparing Monalisa with the Berkeley Advanced Reconstruction Toolbox (BART) toolbox on simulated 2D radial acquisitions. Results: Results of the comparison demonstrate competitive performance, yielding higher Structural Similarity Index (SSIM) and lower l 2 error. Notably, Monalisa reconstructions exhibited fewer visible artifacts than BART. Conclusion: By providing comprehensive documentation, Monalisa serves not only as a powerful tool for research and clinical imaging but also as an educational platform to facilitate innovation in MRI reconstruction.
Open AccessMonalisa: an open source, documented MATLAB toolbox for magnetic resonance imaging reconstruction
Summary: Purpose: An open-source, user-friendly MATLAB framework for Magnetic Resonance Imaging (MRI) reconstruction was developed to simplify the reconstruction process, with a specific focus on non-Cartesian imaging and dynamic applications in the presence of motion. Methods: Monalisa is decomposing the reconstruction pipeline into clear modular steps, including raw data reading with flexible file-type abstraction, trajectory computation, density compensation, advanced coil sensitivity mapping, and tailored binning strategies through its “mitosius” preprocessing stage. The framework supports a suite of reconstruction methods, including iterative-SENSE (also named CG-SENSE), GeneRalized Autocalibrating Partial Parallel Acquisition (GRAPPA) reconstructions, and regularized reconstructions supporting both spatial and temporal regularization using l 1 (Compressed Sensing (CS)) and l 2 techniques, accommodating both Cartesian and non-Cartesian acquisitions. We performed benchmark experiments comparing Monalisa with the Berkeley Advanced Reconstruction Toolbox (BART) toolbox on simulated 2D radial acquisitions. Results: Results of the comparison demonstrate competitive performance, yielding higher Structural Similarity Index (SSIM) and lower l 2 error. Notably, Monalisa reconstructions exhibited fewer visible artifacts than BART. Conclusion: By providing comprehensive documentation, Monalisa serves not only as a powerful tool for research and clinical imaging but also as an educational platform to facilitate innovation in MRI reconstruction.