CKCatarina Redshaw Kranich

Catarina Redshaw Kranich

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Research Subjects


Catarina Redshaw Kranich has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Open-source cardiac magnetic resonance fingerprinting

    by Patrick Schuenke, Catarina Redshaw Kranich, Max Lutz, Jakob Schattenfroh, Matthias Anders, Philine Reisdorf, Jeanette Schulz-Menger, Ingolf Sack, Jesse Hamilton, Nicole Seiberlich, et al.

    Purpose: Cardiac magnetic resonance fingerprinting (cMRF) is a powerful quantitative imaging technique that provides multi-parametric diagnostic information. Here, we introduce an open-source framework for cardiac MRF including open-source pulse sequences, image reconstruction, and parameter estimation tools that are needed for the processing of the data. Methods: A 2D cMRF sequence with a variable-density spiral readout is implemented using the open-source and vendor-agnostic sequence format Pulseq. Cardiac triggering is used to synchronize acquisition with the rest period of the heart. $$T_1$$ T 1 inversion and $$T_2$$ T 2 preparation pulses are added to ensure accurate parameter estimation. Data acquisition is carried out over 15 heartbeats. The images showing the signal changes over time are reconstructed and matched to a pre-calculated signal dictionary. In addition to the cMRF sequence, spin-echo reference sequences for quality control in phantoms are provided. The method is evaluated in phantom experiments using a T1MES phantom on four different scanners. In vivo experiments were performed to compare the open-source cMRF sequence with a vendor-specific cMRF sequence and clinical sequences used for $$T_1$$ T 1 and $$T_2$$ T 2 mapping of the heart. Three volunteers were imaged on two different scanners. Results: The error of $$T_1$$ T 1 and $$T_2$$ T 2 over all tissue types present in the T1MES phantom was comparable between all four scanners and on average 4.50 ± 2.48%. $$T_1$$ T 1 and $$T_2$$ T 2 maps obtained in vivo were comparable between the open-source and vendor-specific implementation of cMRF. Conclusion: The proposed open-source cMRF implementation enables accurate parameter estimation across multiple different scanners. Sequence files, image reconstruction, and parameter estimation scripts are available for reproducible quantitative MRI.