MAMatthias Anders
Matthias Anders
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Matthias Anders has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Catarina Redshaw Kranich
Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
1 shared publication - Christoph Kolbitsch
Physikalisch‐Technische Bundesanstalt (PTB) Braunschweig and Berlin Germany
1 shared publication - Ingolf Sack
Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
1 shared publication - Jakob Schattenfroh
Department of Radiology, Charite-Universitatsmedizin Berlin, Berlin, Germany
1 shared publication - Jeanette Schulz-Menger
Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Deutschland
1 shared publication - Jesse I. Hamilton
Department of Biomedical Engineering University of Michigan Ann Arbor Michigan USA
1 shared publication
Latest Publications
- Open Access
- 21 June 2025
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 38 (4) , 1-13
Open-source cardiac magnetic resonance fingerprinting
Purpose: Cardiac magnetic resonance fingerprinting (cMRF) is a powerful quantitative imaging technique that provides multi-parametric diagnostic information. Here, we introduce an open-source framework for cardiac MRF including open-source pulse sequences, image reconstruction, and parameter estimation tools that are needed for the processing of the data. Methods: A 2D cMRF sequence with a variable-density spiral readout is implemented using the open-source and vendor-agnostic sequence format Pulseq. Cardiac triggering is used to synchronize acquisition with the rest period of the heart. $$T_1$$ inversion and $$T_2$$ preparation pulses are added to ensure accurate parameter estimation. Data acquisition is carried out over 15 heartbeats. The images showing the signal changes over time are reconstructed and matched to a pre-calculated signal dictionary. In addition to the cMRF sequence, spin-echo reference sequences for quality control in phantoms are provided. The method is evaluated in phantom experiments using a T1MES phantom on four different scanners. In vivo experiments were performed to compare the open-source cMRF sequence with a vendor-specific cMRF sequence and clinical sequences used for $$T_1$$ and $$T_2$$ mapping of the heart. Three volunteers were imaged on two different scanners. Results: The error of $$T_1$$ and $$T_2$$ over all tissue types present in the T1MES phantom was comparable between all four scanners and on average 4.50 ± 2.48%. $$T_1$$ and $$T_2$$ maps obtained in vivo were comparable between the open-source and vendor-specific implementation of cMRF. Conclusion: The proposed open-source cMRF implementation enables accurate parameter estimation across multiple different scanners. Sequence files, image reconstruction, and parameter estimation scripts are available for reproducible quantitative MRI.- 21 June 2025
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 38 (4) , 1-13
Open AccessOpen-source cardiac magnetic resonance fingerprinting
Purpose: Cardiac magnetic resonance fingerprinting (cMRF) is a powerful quantitative imaging technique that provides multi-parametric diagnostic information. Here, we introduce an open-source framework for cardiac MRF including open-source pulse sequences, image reconstruction, and parameter estimation tools that are needed for the processing of the data. Methods: A 2D cMRF sequence with a variable-density spiral readout is implemented using the open-source and vendor-agnostic sequence format Pulseq. Cardiac triggering is used to synchronize acquisition with the rest period of the heart. $$T_1$$ inversion and $$T_2$$ preparation pulses are added to ensure accurate parameter estimation. Data acquisition is carried out over 15 heartbeats. The images showing the signal changes over time are reconstructed and matched to a pre-calculated signal dictionary. In addition to the cMRF sequence, spin-echo reference sequences for quality control in phantoms are provided. The method is evaluated in phantom experiments using a T1MES phantom on four different scanners. In vivo experiments were performed to compare the open-source cMRF sequence with a vendor-specific cMRF sequence and clinical sequences used for $$T_1$$ and $$T_2$$ mapping of the heart. Three volunteers were imaged on two different scanners. Results: The error of $$T_1$$ and $$T_2$$ over all tissue types present in the T1MES phantom was comparable between all four scanners and on average 4.50 ± 2.48%. $$T_1$$ and $$T_2$$ maps obtained in vivo were comparable between the open-source and vendor-specific implementation of cMRF. Conclusion: The proposed open-source cMRF implementation enables accurate parameter estimation across multiple different scanners. Sequence files, image reconstruction, and parameter estimation scripts are available for reproducible quantitative MRI.