Christophe Buyck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christophe Buyck has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Hein Heidbuchel
Research Group Cardiovascular Diseases, GENCOR, University of Antwerp, Antwerp, Belgium
6 shared publications - Lien Desteghe
Department of Cardiology, Antwerp University Hospital , Antwerp
6 shared publications - Paulien Vermunicht
Research Group Cardiovascular Diseases, University of Antwerp, Drie Eikenstraat 655, Antwerp, 2650, Belgium, 3238212195
6 shared publications - Sebastiaan Naessens
Department of Cardiology, Antwerp University Hospital, Antwerp, Belgium
5 shared publications - Wendy Hens
Department of Cardiology, Antwerp University Hospital, Antwerp, Belgium
5 shared publications - Emeline M. Van Craenenbroeck
Department of Cardiology, Antwerp University Hospital , Drie Eikenstraat 655, Edegem B-2650
4 shared publications
Latest Publications
- Open Access
- 18 November 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Transmural physical activity monitoring and guidance in long-term maintenance cardiac rehabilitation using a heart rate-based activity algorithm: Design of the AMAAI randomised controlled trial (Preprint)
BACKGROUND The transition from supervised outpatient multidisciplinary cardiac rehabilitation (CR) to the independent long-term maintenance phase of CR is a critical yet currently under-supported period, often leading to reduced physical activity (PA) adherence and poorer cardiovascular outcomes. Continuous heart rate monitoring offers a physiological approach to objective, long-term PA guidance, but translating wearable data into personal, actionable clinical guidance remains difficult. OBJECTIVE To evaluate whether the Antwerp Activity Index (AAI), a personalised HR-based PA scoring workflow, improves adherence to World Health Organization (WHO) PA guidelines during the independent maintenance phase of CR. Secondary objectives include assessing self-reported versus objectively measured PA, changes in cardiorespiratory fitness, intervention adherence, atrial fibrillation burden, system performance, and validation of a fitness evolution prediction model. METHODS AMAAI is a prospective, multicentre randomised controlled trial. During supervised outpatient multidisciplinary CR, patients undergo a photoplethysmography compatibility assessment. Compatible patients (target n=233) are randomised 1:1. The control group undergoes blinded smartwatch-based activity score follow-up. The intervention group receives individualised PA targets based on the AAI score and semi-automated feedback over a 16-week long-term CR maintenance period. The primary outcome is the per-participant proportion of follow-up weeks in which ≥150 minutes of WHO-equivalent PA is objectively achieved over the 16-week period. RESULTS Recruitment started in February 2026 across two Belgian centres (Antwerp University Hospital and Jessa Hospital Hasselt). CONCLUSIONS AMAAI is one of the first trials to prospectively evaluate a fully automated, individualised, HR-based PA monitoring and guidance workflow in the maintenance phase of CR. CLINICALTRIAL ClinicalTrials.gov NCT07211282
- 18 November 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessTransmural physical activity monitoring and guidance in long-term maintenance cardiac rehabilitation using a heart rate-based activity algorithm: Design of the AMAAI randomised controlled trial (Preprint)
BACKGROUND The transition from supervised outpatient multidisciplinary cardiac rehabilitation (CR) to the independent long-term maintenance phase of CR is a critical yet currently under-supported period, often leading to reduced physical activity (PA) adherence and poorer cardiovascular outcomes. Continuous heart rate monitoring offers a physiological approach to objective, long-term PA guidance, but translating wearable data into personal, actionable clinical guidance remains difficult. OBJECTIVE To evaluate whether the Antwerp Activity Index (AAI), a personalised HR-based PA scoring workflow, improves adherence to World Health Organization (WHO) PA guidelines during the independent maintenance phase of CR. Secondary objectives include assessing self-reported versus objectively measured PA, changes in cardiorespiratory fitness, intervention adherence, atrial fibrillation burden, system performance, and validation of a fitness evolution prediction model. METHODS AMAAI is a prospective, multicentre randomised controlled trial. During supervised outpatient multidisciplinary CR, patients undergo a photoplethysmography compatibility assessment. Compatible patients (target n=233) are randomised 1:1. The control group undergoes blinded smartwatch-based activity score follow-up. The intervention group receives individualised PA targets based on the AAI score and semi-automated feedback over a 16-week long-term CR maintenance period. The primary outcome is the per-participant proportion of follow-up weeks in which ≥150 minutes of WHO-equivalent PA is objectively achieved over the 16-week period. RESULTS Recruitment started in February 2026 across two Belgian centres (Antwerp University Hospital and Jessa Hospital Hasselt). CONCLUSIONS AMAAI is one of the first trials to prospectively evaluate a fully automated, individualised, HR-based PA monitoring and guidance workflow in the maintenance phase of CR. CLINICALTRIAL ClinicalTrials.gov NCT07211282
- Open Access
- 17 June 2026
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 14 (1) , e79995
Heart Rate Monitors for the Estimation of Physical Activity in Patients With Cardiovascular Disease: Systematic Review
Background: Heart rate (HR) monitoring by wearable devices offers a physiological, personalized, and continuous method for assessing physical activity (PA) duration and intensity. However, methods to translate HR data into meaningful PA metrics are diverse and nonstandardized. Objective: This study aims to provide an overview of how HR data are used to quantify PA behavior and estimate physiological outcomes in adult patients with cardiovascular disease (CVD). Methods: A systematic search was performed in PubMed, Web of Science, and CENTRAL for studies published between 2014 and 2024. Eligible studies included adults with CVD or related risk factors wearing HR monitors to estimate PA. Data were synthesized narratively. The methodological quality of the included studies was evaluated using the Crowe Critical Appraisal Tool (CCAT; Michael Crowe). Results: Twenty studies were included, spanning four HR-based PA estimation methods: (1) HR zone analysis (n=14), which assessed time spent in moderate-to-vigorous zones to evaluate guideline or training adherence; (2) physiological modeling (n=4), estimating outcomes such as energy expenditure (physical activity level) or cardiorespiratory fitness (maximal oxygen uptake); (3) change detection (n=1), using time-series and machine learning algorithms to quantify shifts in PA behavior; and (4) a derived personalized scoring system (n=1). While each approach demonstrated clinical promise of using HR data, external validation, and methodological transparency is often lacking. Conclusions: HR-based PA estimation holds the promise of physiologically meaningful, personalized PA monitoring in CVD care. Modeling approaches and personalized scoring systems linking PA behavior to cardiovascular outcomes may provide highly needed clinical tools for PA management in patients. Research should prioritize algorithm transparency, clinical validation, and standardization.
- 17 June 2026
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 14 (1) , e79995
Open AccessHeart Rate Monitors for the Estimation of Physical Activity in Patients With Cardiovascular Disease: Systematic Review
Background: Heart rate (HR) monitoring by wearable devices offers a physiological, personalized, and continuous method for assessing physical activity (PA) duration and intensity. However, methods to translate HR data into meaningful PA metrics are diverse and nonstandardized. Objective: This study aims to provide an overview of how HR data are used to quantify PA behavior and estimate physiological outcomes in adult patients with cardiovascular disease (CVD). Methods: A systematic search was performed in PubMed, Web of Science, and CENTRAL for studies published between 2014 and 2024. Eligible studies included adults with CVD or related risk factors wearing HR monitors to estimate PA. Data were synthesized narratively. The methodological quality of the included studies was evaluated using the Crowe Critical Appraisal Tool (CCAT; Michael Crowe). Results: Twenty studies were included, spanning four HR-based PA estimation methods: (1) HR zone analysis (n=14), which assessed time spent in moderate-to-vigorous zones to evaluate guideline or training adherence; (2) physiological modeling (n=4), estimating outcomes such as energy expenditure (physical activity level) or cardiorespiratory fitness (maximal oxygen uptake); (3) change detection (n=1), using time-series and machine learning algorithms to quantify shifts in PA behavior; and (4) a derived personalized scoring system (n=1). While each approach demonstrated clinical promise of using HR data, external validation, and methodological transparency is often lacking. Conclusions: HR-based PA estimation holds the promise of physiologically meaningful, personalized PA monitoring in CVD care. Modeling approaches and personalized scoring systems linking PA behavior to cardiovascular outcomes may provide highly needed clinical tools for PA management in patients. Research should prioritize algorithm transparency, clinical validation, and standardization.
- Open Access
- 22 April 2026
- Published by Oxford University Press (OUP) in European Journal of Preventive Cardiology
High heart rate peaks from chest-strap recordings in athletes: prevalence, characteristics, and clinical relevance
Aims: This study aims to evaluate the prevalence, morphology, and clinical relevance of transient, extreme heart rate (HR) spikes on heart rate monitors (HRMs) in endurance athletes. Methods and results: Heart rate monitor training sessions (n = 57 282) from 251 endurance athletes (167 Pro@Heart; 84 Master@Heart), were analysed. Individual physiological maximal HR (HRmaxTan) was determined using the kernel density of peak HR values. Extreme HR events were defined as sessions exceeding this limit (HRmaxHRM). Tracings were visually classified; paroxysmal spikes were considered to be potential tachyarrhythmia. Incidence was estimated with Kaplan–Meier analysis. Demographic, training, and device predictors were tested with a generalized linear mixed model (GLMM). Clinical and Holter data were reviewed for arrhythmia documentation. Extreme HR values occurred in 1.0% of sessions across 133 athletes (53.0%). Paroxysmal spikes represented 28.1% of cases and occurred in 0.27% of sessions and 23.9% of athletes, cumulative incidence was 33.8% (95% confidence interval [CI], 26.1–41.4%) after 291 sessions. The GLMM identified no significant predictors. Paroxysmal spikes were observed in 71.4% of athletes (10/14) with arrhythmia vs. 21.1% without (50/237) (P < 0.001). Nearly all HRmaxHRM spikes preceded Holter-documented arrhythmias. Conclusion: Many characteristics point to true arrhythmias as the cause of HRmaxHRM recordings with paroxysmal spike morphology: they are rare, do not occur randomly across athletes, and cosegregate with clinically documented arrhythmias. Whether they represent malignant arrhythmias or an extreme athletic cardiac phenotype remains to be determined and is relevant to the role of HRMs as surveillance tools. HRmaxHRM tracings with spike morphology should not be dismissed as artefact but require work-up to determine clinical relevance.
- 22 April 2026
- Published by Oxford University Press (OUP) in European Journal of Preventive Cardiology
Open AccessHigh heart rate peaks from chest-strap recordings in athletes: prevalence, characteristics, and clinical relevance
Aims: This study aims to evaluate the prevalence, morphology, and clinical relevance of transient, extreme heart rate (HR) spikes on heart rate monitors (HRMs) in endurance athletes. Methods and results: Heart rate monitor training sessions (n = 57 282) from 251 endurance athletes (167 Pro@Heart; 84 Master@Heart), were analysed. Individual physiological maximal HR (HRmaxTan) was determined using the kernel density of peak HR values. Extreme HR events were defined as sessions exceeding this limit (HRmaxHRM). Tracings were visually classified; paroxysmal spikes were considered to be potential tachyarrhythmia. Incidence was estimated with Kaplan–Meier analysis. Demographic, training, and device predictors were tested with a generalized linear mixed model (GLMM). Clinical and Holter data were reviewed for arrhythmia documentation. Extreme HR values occurred in 1.0% of sessions across 133 athletes (53.0%). Paroxysmal spikes represented 28.1% of cases and occurred in 0.27% of sessions and 23.9% of athletes, cumulative incidence was 33.8% (95% confidence interval [CI], 26.1–41.4%) after 291 sessions. The GLMM identified no significant predictors. Paroxysmal spikes were observed in 71.4% of athletes (10/14) with arrhythmia vs. 21.1% without (50/237) (P < 0.001). Nearly all HRmaxHRM spikes preceded Holter-documented arrhythmias. Conclusion: Many characteristics point to true arrhythmias as the cause of HRmaxHRM recordings with paroxysmal spike morphology: they are rare, do not occur randomly across athletes, and cosegregate with clinically documented arrhythmias. Whether they represent malignant arrhythmias or an extreme athletic cardiac phenotype remains to be determined and is relevant to the role of HRMs as surveillance tools. HRmaxHRM tracings with spike morphology should not be dismissed as artefact but require work-up to determine clinical relevance.
- Open Access
- 1 February 2026
- Published by SAGE Publications in Digital Health
- Vol. 12
A novel machine learning procedure to detect and remove artefacts in heart rate data obtained from photoplethysmography wearables: A prospective cohort study
Introduction: Photoplethysmography (PPG) based heart rate (HR) monitoring supports continuous assessment of physical activity intensity, but device generated HR values remain prone to motion artefacts. This study validated a novel machine learning procedure that detects artefacts directly in PPG derived HR data, rather than in raw waveforms that are unavailable in commercial devices. Methods: In this prospective study, 149 participants (46 following cardiac rehabilitation, 103 healthy) wore a PPG-based wrist device and a reference chest strap for 12 weeks. Prior testing defined participants as “PPG-compatible” (i.e., HR error 50% and activity probability r = . 89–.96). Conclusions: This new machine learning-based procedure, which operates on device-generated HR rather than PPG waveforms, effectively removes artefacts while preserving key activity signals, ensuring clinically relevant PA assessment in daily life.
- 1 February 2026
- Published by SAGE Publications in Digital Health
- Vol. 12
Open AccessA novel machine learning procedure to detect and remove artefacts in heart rate data obtained from photoplethysmography wearables: A prospective cohort study
Introduction: Photoplethysmography (PPG) based heart rate (HR) monitoring supports continuous assessment of physical activity intensity, but device generated HR values remain prone to motion artefacts. This study validated a novel machine learning procedure that detects artefacts directly in PPG derived HR data, rather than in raw waveforms that are unavailable in commercial devices. Methods: In this prospective study, 149 participants (46 following cardiac rehabilitation, 103 healthy) wore a PPG-based wrist device and a reference chest strap for 12 weeks. Prior testing defined participants as “PPG-compatible” (i.e., HR error 50% and activity probability r = . 89–.96). Conclusions: This new machine learning-based procedure, which operates on device-generated HR rather than PPG waveforms, effectively removes artefacts while preserving key activity signals, ensuring clinically relevant PA assessment in daily life.
- Open Access
- 23 July 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 6 (5) , 1024-1035
Optimisation and pre-use suitability selection for wrist photo-plethysmography based heart rate monitoring in cardiac patients
Introduction: Sensor placement, activity type influencing wrist movements, and individual characteristics impact accuracy of wrist-worn photoplethysmography (PPG)-based heart rate (HR) monitors. This study investigated technical interventions to optimise PPG accuracy in patients with cardiac disease. Methods: The Fitbit Inspire 2 PPG monitor was evaluated across three cohorts, using a Polar H10 chest strap as reference: (1) 10 healthy volunteers performed wrist movements with the monitor placed one or three fingers above the wrist to identify optimal placement; (2) 10 volunteers engaged in sport activities (walking, running, cycling, rowing); (3) 30 cardiac rehabilitation patients were monitored during exercise to assess baseline accuracy. Patients with low accuracy (mean absolute percentage error (MAPE) <10% for <70% of training time) underwent technical interventions (sensor cleaning, forearm shaving, position fixation, and/or relocation to the volar wrist). Results: Placement three vs. one fingers above the wrist was significantly more accurate (mean difference in MAPE: -11.4%, p<0.001). Walking showed the highest accuracy (MAPE=3.8%), followed by cycling (MAPE=6.9%) and running (MAPE=8.5%), while rowing had the lowest accuracy (MAPE=13.4%, p<0.001). Among CR patients, 66.7% achieved high baseline accuracy. Technical interventions improved accuracy in 50.0% of those with low baseline accuracy, but no significant predictors of optimisation success were identified. Conclusions: Accurate PPG-based monitoring requires a sensor placed higher on the wrist. Nevertheless, only two-thirds of patients are suitable for such monitoring, with improvement by technical adaptations possible (but impractical) in the others. Therefore, assessing baseline accuracy is a prerequisite before relying on these devices for activity guidance.
- 23 July 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 6 (5) , 1024-1035
Open AccessOptimisation and pre-use suitability selection for wrist photo-plethysmography based heart rate monitoring in cardiac patients
Introduction: Sensor placement, activity type influencing wrist movements, and individual characteristics impact accuracy of wrist-worn photoplethysmography (PPG)-based heart rate (HR) monitors. This study investigated technical interventions to optimise PPG accuracy in patients with cardiac disease. Methods: The Fitbit Inspire 2 PPG monitor was evaluated across three cohorts, using a Polar H10 chest strap as reference: (1) 10 healthy volunteers performed wrist movements with the monitor placed one or three fingers above the wrist to identify optimal placement; (2) 10 volunteers engaged in sport activities (walking, running, cycling, rowing); (3) 30 cardiac rehabilitation patients were monitored during exercise to assess baseline accuracy. Patients with low accuracy (mean absolute percentage error (MAPE) <10% for <70% of training time) underwent technical interventions (sensor cleaning, forearm shaving, position fixation, and/or relocation to the volar wrist). Results: Placement three vs. one fingers above the wrist was significantly more accurate (mean difference in MAPE: -11.4%, p<0.001). Walking showed the highest accuracy (MAPE=3.8%), followed by cycling (MAPE=6.9%) and running (MAPE=8.5%), while rowing had the lowest accuracy (MAPE=13.4%, p<0.001). Among CR patients, 66.7% achieved high baseline accuracy. Technical interventions improved accuracy in 50.0% of those with low baseline accuracy, but no significant predictors of optimisation success were identified. Conclusions: Accurate PPG-based monitoring requires a sensor placed higher on the wrist. Nevertheless, only two-thirds of patients are suitable for such monitoring, with improvement by technical adaptations possible (but impractical) in the others. Therefore, assessing baseline accuracy is a prerequisite before relying on these devices for activity guidance.
- Open Access
- 1 May 2025
- Published by SAGE Publications in Digital Health
- Vol. 11
Continuous heart rate measurements in patients with cardiac disease: Device comparison and development of a novel artefact removal procedure
Introduction: Heart rate (HR) monitors could objectively measure physical activity intensity in patients with cardiac disease. However, thorough validation of HR monitors in cardiac populations during daily life, compared to gold-standard Holter monitoring, remains limited. Photoplethysmography (PPG)-based HR data provides near-continuous data, spanning longer periods, but improved algorithms to filter unreliable data are needed. Methods: This observational, prospective pilot study compared the accuracy of two wearables for HR monitoring (electrocardiogram [ECG]-based Polar H10 chest strap and PPG-based Fitbit Inspire 2 wrist tracker) against Holter monitoring in 15 patients with atrial fibrillation (AF), heart failure (HF) and coronary artery disease referred for cardiac rehabilitation (CR). All devices were worn simultaneously for 24 h. We developed and assessed an artefact removal procedure (ARP) using logistic regression machine learning models to detect unreliable PPG data. Results: The ECG-based chest strap showed a strong correlation ( r = 0.94) and clinically acceptable errors (mean absolute error, MAE = 3.4 bpm; mean absolute percentage error, MAPE = 4.9%). Photoplethysmography data exhibited weaker correlation ( r = 0.69) and higher errors (MAE = 8.3 bpm, MAPE = 14.3%), with highest accuracies in CR and lowest in HF and especially AF. After implementing the ARP, PPG-based HR data improved to a correlation of 0.75, with MAE of 7.2 bpm and MAPE of 12.4%. The procedure removed nearly one-third of unreliable data, achieving an 81% accuracy. Conclusions: While ECG-based monitors provide HR data with clinical acceptable accuracy, PPG-based monitors present accuracy challenges. Our machine learning procedure showed potential to filter unreliable PPG-based HR data, which could help measure physical activity intensity in cardiac disease continuously.
- 1 May 2025
- Published by SAGE Publications in Digital Health
- Vol. 11
Open AccessContinuous heart rate measurements in patients with cardiac disease: Device comparison and development of a novel artefact removal procedure
Introduction: Heart rate (HR) monitors could objectively measure physical activity intensity in patients with cardiac disease. However, thorough validation of HR monitors in cardiac populations during daily life, compared to gold-standard Holter monitoring, remains limited. Photoplethysmography (PPG)-based HR data provides near-continuous data, spanning longer periods, but improved algorithms to filter unreliable data are needed. Methods: This observational, prospective pilot study compared the accuracy of two wearables for HR monitoring (electrocardiogram [ECG]-based Polar H10 chest strap and PPG-based Fitbit Inspire 2 wrist tracker) against Holter monitoring in 15 patients with atrial fibrillation (AF), heart failure (HF) and coronary artery disease referred for cardiac rehabilitation (CR). All devices were worn simultaneously for 24 h. We developed and assessed an artefact removal procedure (ARP) using logistic regression machine learning models to detect unreliable PPG data. Results: The ECG-based chest strap showed a strong correlation ( r = 0.94) and clinically acceptable errors (mean absolute error, MAE = 3.4 bpm; mean absolute percentage error, MAPE = 4.9%). Photoplethysmography data exhibited weaker correlation ( r = 0.69) and higher errors (MAE = 8.3 bpm, MAPE = 14.3%), with highest accuracies in CR and lowest in HF and especially AF. After implementing the ARP, PPG-based HR data improved to a correlation of 0.75, with MAE of 7.2 bpm and MAPE of 12.4%. The procedure removed nearly one-third of unreliable data, achieving an 81% accuracy. Conclusions: While ECG-based monitors provide HR data with clinical acceptable accuracy, PPG-based monitors present accuracy challenges. Our machine learning procedure showed potential to filter unreliable PPG-based HR data, which could help measure physical activity intensity in cardiac disease continuously.