WHWendy Hens

Wendy Hens

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wendy Hens has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Transmural physical activity monitoring and guidance in long-term maintenance cardiac rehabilitation using a heart rate-based activity algorithm: Design of the AMAAI randomised controlled trial (Preprint)

    by Christophe Buyck, Paulien Vermunicht, Anouk Delaet, Sebastiaan Naessens, Wendy Hens, Juan Sebastian Piedrahita Giraldo, Halil Ibrahim Ceylan, Rik Theunis, Peter Gorissen, Kris Laukens, et al.

    BACKGROUND The transition from supervised outpatient multidisciplinary cardiac rehabilitation (CR) to the independent long-term maintenance phase of CR is a critical yet currently under-supported period, often leading to reduced physical activity (PA) adherence and poorer cardiovascular outcomes. Continuous heart rate monitoring offers a physiological approach to objective, long-term PA guidance, but translating wearable data into personal, actionable clinical guidance remains difficult. OBJECTIVE To evaluate whether the Antwerp Activity Index (AAI), a personalised HR-based PA scoring workflow, improves adherence to World Health Organization (WHO) PA guidelines during the independent maintenance phase of CR. Secondary objectives include assessing self-reported versus objectively measured PA, changes in cardiorespiratory fitness, intervention adherence, atrial fibrillation burden, system performance, and validation of a fitness evolution prediction model. METHODS AMAAI is a prospective, multicentre randomised controlled trial. During supervised outpatient multidisciplinary CR, patients undergo a photoplethysmography compatibility assessment. Compatible patients (target n=233) are randomised 1:1. The control group undergoes blinded smartwatch-based activity score follow-up. The intervention group receives individualised PA targets based on the AAI score and semi-automated feedback over a 16-week long-term CR maintenance period. The primary outcome is the per-participant proportion of follow-up weeks in which ≥150 minutes of WHO-equivalent PA is objectively achieved over the 16-week period. RESULTS Recruitment started in February 2026 across two Belgian centres (Antwerp University Hospital and Jessa Hospital Hasselt). CONCLUSIONS AMAAI is one of the first trials to prospectively evaluate a fully automated, individualised, HR-based PA monitoring and guidance workflow in the maintenance phase of CR. CLINICALTRIAL ClinicalTrials.gov NCT07211282

  • Open Access

    Heart Rate Monitors for the Estimation of Physical Activity in Patients With Cardiovascular Disease: Systematic Review

    by Paulien Vermunicht, Christophe Buyck, Sebastiaan Naessens, Wendy Hens, Emeline Van Craenenbroeck, Kris Laukens, Lien Desteghe, Hein Heidbuchel

    Background: Heart rate (HR) monitoring by wearable devices offers a physiological, personalized, and continuous method for assessing physical activity (PA) duration and intensity. However, methods to translate HR data into meaningful PA metrics are diverse and nonstandardized. Objective: This study aims to provide an overview of how HR data are used to quantify PA behavior and estimate physiological outcomes in adult patients with cardiovascular disease (CVD). Methods: A systematic search was performed in PubMed, Web of Science, and CENTRAL for studies published between 2014 and 2024. Eligible studies included adults with CVD or related risk factors wearing HR monitors to estimate PA. Data were synthesized narratively. The methodological quality of the included studies was evaluated using the Crowe Critical Appraisal Tool (CCAT; Michael Crowe). Results: Twenty studies were included, spanning four HR-based PA estimation methods: (1) HR zone analysis (n=14), which assessed time spent in moderate-to-vigorous zones to evaluate guideline or training adherence; (2) physiological modeling (n=4), estimating outcomes such as energy expenditure (physical activity level) or cardiorespiratory fitness (maximal oxygen uptake); (3) change detection (n=1), using time-series and machine learning algorithms to quantify shifts in PA behavior; and (4) a derived personalized scoring system (n=1). While each approach demonstrated clinical promise of using HR data, external validation, and methodological transparency is often lacking. Conclusions: HR-based PA estimation holds the promise of physiologically meaningful, personalized PA monitoring in CVD care. Modeling approaches and personalized scoring systems linking PA behavior to cardiovascular outcomes may provide highly needed clinical tools for PA management in patients. Research should prioritize algorithm transparency, clinical validation, and standardization.

  • Open Access

    A novel machine learning procedure to detect and remove artefacts in heart rate data obtained from photoplethysmography wearables: A prospective cohort study

    by Paulien Vermunicht, Christophe Buyck, Sebastiaan Naessens, Wendy Hens, Emeline Van Craenenbroeck, Juan Sebastian Piedrahita Giraldo, Katsiaryna Makayed, Saartje Herman, Kris Laukens, Johan Roeykens, et al.

    Introduction: Photoplethysmography (PPG) based heart rate (HR) monitoring supports continuous assessment of physical activity intensity, but device generated HR values remain prone to motion artefacts. This study validated a novel machine learning procedure that detects artefacts directly in PPG derived HR data, rather than in raw waveforms that are unavailable in commercial devices. Methods: In this prospective study, 149 participants (46 following cardiac rehabilitation, 103 healthy) wore a PPG-based wrist device and a reference chest strap for 12 weeks. Prior testing defined participants as “PPG-compatible” (i.e., HR error 50% and activity probability r = . 89–.96). Conclusions: This new machine learning-based procedure, which operates on device-generated HR rather than PPG waveforms, effectively removes artefacts while preserving key activity signals, ensuring clinically relevant PA assessment in daily life.


  • Open Access

    Optimisation and pre-use suitability selection for wrist photo-plethysmography based heart rate monitoring in cardiac patients

    by Paulien Vermunicht, Christophe Buyck, Sebastiaan Naessens, Wendy Hens, Caro Verberckt, Emeline Van Craenenbroeck, Kris Laukens, Lien Desteghe, Hein Heidbuchel

    Introduction: Sensor placement, activity type influencing wrist movements, and individual characteristics impact accuracy of wrist-worn photoplethysmography (PPG)-based heart rate (HR) monitors. This study investigated technical interventions to optimise PPG accuracy in patients with cardiac disease. Methods: The Fitbit Inspire 2 PPG monitor was evaluated across three cohorts, using a Polar H10 chest strap as reference: (1) 10 healthy volunteers performed wrist movements with the monitor placed one or three fingers above the wrist to identify optimal placement; (2) 10 volunteers engaged in sport activities (walking, running, cycling, rowing); (3) 30 cardiac rehabilitation patients were monitored during exercise to assess baseline accuracy. Patients with low accuracy (mean absolute percentage error (MAPE) <10% for <70% of training time) underwent technical interventions (sensor cleaning, forearm shaving, position fixation, and/or relocation to the volar wrist). Results: Placement three vs. one fingers above the wrist was significantly more accurate (mean difference in MAPE: -11.4%, p<0.001). Walking showed the highest accuracy (MAPE=3.8%), followed by cycling (MAPE=6.9%) and running (MAPE=8.5%), while rowing had the lowest accuracy (MAPE=13.4%, p<0.001). Among CR patients, 66.7% achieved high baseline accuracy. Technical interventions improved accuracy in 50.0% of those with low baseline accuracy, but no significant predictors of optimisation success were identified. Conclusions: Accurate PPG-based monitoring requires a sensor placed higher on the wrist. Nevertheless, only two-thirds of patients are suitable for such monitoring, with improvement by technical adaptations possible (but impractical) in the others. Therefore, assessing baseline accuracy is a prerequisite before relying on these devices for activity guidance.


  • Open Access

    Continuous heart rate measurements in patients with cardiac disease: Device comparison and development of a novel artefact removal procedure

    by Paulien Vermunicht, Katsiaryna Makayed, Christophe Buyck, Lieselotte Knaepen, Juan Sebastian Piedrahita Giraldo, Sebastiaan Naessens, Wendy Hens, Emeline Van Craenenbroeck, Kris Laukens, Lien Desteghe, et al.

    Introduction: Heart rate (HR) monitors could objectively measure physical activity intensity in patients with cardiac disease. However, thorough validation of HR monitors in cardiac populations during daily life, compared to gold-standard Holter monitoring, remains limited. Photoplethysmography (PPG)-based HR data provides near-continuous data, spanning longer periods, but improved algorithms to filter unreliable data are needed. Methods: This observational, prospective pilot study compared the accuracy of two wearables for HR monitoring (electrocardiogram [ECG]-based Polar H10 chest strap and PPG-based Fitbit Inspire 2 wrist tracker) against Holter monitoring in 15 patients with atrial fibrillation (AF), heart failure (HF) and coronary artery disease referred for cardiac rehabilitation (CR). All devices were worn simultaneously for 24 h. We developed and assessed an artefact removal procedure (ARP) using logistic regression machine learning models to detect unreliable PPG data. Results: The ECG-based chest strap showed a strong correlation ( r = 0.94) and clinically acceptable errors (mean absolute error, MAE = 3.4 bpm; mean absolute percentage error, MAPE = 4.9%). Photoplethysmography data exhibited weaker correlation ( r = 0.69) and higher errors (MAE = 8.3 bpm, MAPE = 14.3%), with highest accuracies in CR and lowest in HF and especially AF. After implementing the ARP, PPG-based HR data improved to a correlation of 0.75, with MAE of 7.2 bpm and MAPE of 12.4%. The procedure removed nearly one-third of unreliable data, achieving an 81% accuracy. Conclusions: While ECG-based monitors provide HR data with clinical acceptable accuracy, PPG-based monitors present accuracy challenges. Our machine learning procedure showed potential to filter unreliable PPG-based HR data, which could help measure physical activity intensity in cardiac disease continuously.