Ruisen Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ruisen Li has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Han Wang
School of Infrastructure Engineering, Nanchang University, Nanchang 330031, China
1 shared publication - Jiayuan Xu
National Science Library, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication - Lei Zhang
School of Water Conservancy and Civil Engineering, Northeast Agricultural University, Harbin 150030, China
1 shared publication - Qiang Fu
State Key Laboratory of Rice Biology and Breeding, China National Rice Research Institute, Hangzhou, China
1 shared publication - Sheng Li
School of Software Engineering, Jiangxi University of Science and Technology, Nanchang 330013, China
1 shared publication - Wei Wang
School of Civil Engineering, Harbin Institute of Technology, Harbin 150039, China
1 shared publication
Latest Publications
- Open Access
Effects of Unconventional Supplementary Cementitious Materials on the Mechanical Strength and Environmental Benefits of Cement-Based Materials—Multi-Objective Optimization for Separately Modified Mortars
This study experimentally investigates the mechanical properties and development patterns of mortars incorporating steel slag (SS), coal gangue (CG), and biochar (BC) and establishes a multi-objective optimization framework for sustainable mix design. The investigation systematically evaluates the individual effects of these materials on mechanical properties, economic cost, and environmental impact, providing a comparative basis for single-SCM mix design. Experimental results demonstrate distinct material-specific behaviors: SS substitution (10–40%) exhibits behavior consistent with latent hydraulic activity, mitigating early-age strength loss and showing a relative 28-day strength recovery from 71.4% to 80.5% at 30% substitution. CG acts primarily as a filler-type component under the tested conditions, causing a progressive, dosage-dependent strength reduction, with 28-day relative strength declining to 46.4% at 40% substitution. In contrast, BC at low dosages (1–2%) functions as a performance-enhancing cement replacement, improving 28-day compressive strength by up to 11.7% within the tested curing period through physical effects supported by the previous literature. Preliminary environmental screening indicates that both SS and CG significantly reduce cost (down to 2421.6 and 2410.2 CNY/m3, respectively), energy consumption (down to 3645.3 and 3028.6 MJ/m3), and carbon footprint (down to 492.2 and 438.0 kg CO2-eq/m3) at 40% substitution. Conversely, BC increases cost and energy demand but reduces carbon emissions (619.8 kg CO2-eq/m3 at 4% replacement) under the adopted carbon sequestration assumption. The optimization model successfully identifies Pareto-optimal mixtures that balance the trade-offs between superior mechanical performance, cost-effectiveness, and reduced environmental impact, providing viable strategies for developing sustainable construction materials through the separate utilization of industrial and agricultural waste streams.
Open AccessEffects of Unconventional Supplementary Cementitious Materials on the Mechanical Strength and Environmental Benefits of Cement-Based Materials—Multi-Objective Optimization for Separately Modified Mortars
This study experimentally investigates the mechanical properties and development patterns of mortars incorporating steel slag (SS), coal gangue (CG), and biochar (BC) and establishes a multi-objective optimization framework for sustainable mix design. The investigation systematically evaluates the individual effects of these materials on mechanical properties, economic cost, and environmental impact, providing a comparative basis for single-SCM mix design. Experimental results demonstrate distinct material-specific behaviors: SS substitution (10–40%) exhibits behavior consistent with latent hydraulic activity, mitigating early-age strength loss and showing a relative 28-day strength recovery from 71.4% to 80.5% at 30% substitution. CG acts primarily as a filler-type component under the tested conditions, causing a progressive, dosage-dependent strength reduction, with 28-day relative strength declining to 46.4% at 40% substitution. In contrast, BC at low dosages (1–2%) functions as a performance-enhancing cement replacement, improving 28-day compressive strength by up to 11.7% within the tested curing period through physical effects supported by the previous literature. Preliminary environmental screening indicates that both SS and CG significantly reduce cost (down to 2421.6 and 2410.2 CNY/m3, respectively), energy consumption (down to 3645.3 and 3028.6 MJ/m3), and carbon footprint (down to 492.2 and 438.0 kg CO2-eq/m3) at 40% substitution. Conversely, BC increases cost and energy demand but reduces carbon emissions (619.8 kg CO2-eq/m3 at 4% replacement) under the adopted carbon sequestration assumption. The optimization model successfully identifies Pareto-optimal mixtures that balance the trade-offs between superior mechanical performance, cost-effectiveness, and reduced environmental impact, providing viable strategies for developing sustainable construction materials through the separate utilization of industrial and agricultural waste streams.
- Open Access
Mechanical Strength and Hydration Characteristic of Multiple Common Waste-Blended Cement-Based Materials Cured by Electric-Induced Heating Curing Under Severely Cold Environments
To address the challenges of concrete construction in polar regions, this study investigates the feasibility of fabricating cement-based materials under severely low temperatures using electric-induced heating curing methods. Cement mortars incorporating fly ash (FA-CM), ground granulated blast furnace slag (GGBS-CM), and metakaolin (MK-CM) were cured at environmental temperatures of −20 °C, −40 °C, and −60 °C. The optimal carbon fiber (CF) contents were determined using the initial electric resistivity to ensure a consistent electric-induced heating curing process. The thermal profiles during curing were monitored, and mechanical strength development was systematically evaluated. Hydration characteristics were elucidated through thermogravimetric analysis (TG), X-ray diffraction (XRD), and Fourier-transform infrared spectroscopy (FTIR) to identify phase compositions and reaction products. Results demonstrate that electric-induced heating effectively mitigates the adverse effect caused by the ultra-low temperature constraints, with distinct differences in the strength performance and hydration kinetics among supplementary cementitious materials. MK-CM exhibited superior early strength development with strength increasing rates above 10% compared to the Ref. specimen, which was attributed to the accelerated pozzolanic reactions. Microstructural analyses further verified the macroscopic strength test results that showed that electric-induced heating curing can effectively promote the performance development even under severely cold environments with a higher hydration degree and refined micro-pore structure. This work proposes a viable strategy for polar construction applications.
Open AccessMechanical Strength and Hydration Characteristic of Multiple Common Waste-Blended Cement-Based Materials Cured by Electric-Induced Heating Curing Under Severely Cold Environments
To address the challenges of concrete construction in polar regions, this study investigates the feasibility of fabricating cement-based materials under severely low temperatures using electric-induced heating curing methods. Cement mortars incorporating fly ash (FA-CM), ground granulated blast furnace slag (GGBS-CM), and metakaolin (MK-CM) were cured at environmental temperatures of −20 °C, −40 °C, and −60 °C. The optimal carbon fiber (CF) contents were determined using the initial electric resistivity to ensure a consistent electric-induced heating curing process. The thermal profiles during curing were monitored, and mechanical strength development was systematically evaluated. Hydration characteristics were elucidated through thermogravimetric analysis (TG), X-ray diffraction (XRD), and Fourier-transform infrared spectroscopy (FTIR) to identify phase compositions and reaction products. Results demonstrate that electric-induced heating effectively mitigates the adverse effect caused by the ultra-low temperature constraints, with distinct differences in the strength performance and hydration kinetics among supplementary cementitious materials. MK-CM exhibited superior early strength development with strength increasing rates above 10% compared to the Ref. specimen, which was attributed to the accelerated pozzolanic reactions. Microstructural analyses further verified the macroscopic strength test results that showed that electric-induced heating curing can effectively promote the performance development even under severely cold environments with a higher hydration degree and refined micro-pore structure. This work proposes a viable strategy for polar construction applications.