Jisun Ham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jisun Ham has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Junyeol Maeng
Department of Electrical and Computer Engineering and SNU Electric Power Research Institute, Seoul National University, Seoul, South Korea
3 shared publications - Shenghui Cui
Department of Electrical and Computer Engineering and SNU Electric Power Research Institute, Seoul National University, Seoul, South Korea
3 shared publications - Jaeyeon Park
Department of Electrical and Computer Engineering and SNU Electric Power Research Institute, Seoul National University, Seoul, South Korea
2 shared publications - Chaemin Im
Department of Electrical and Computer Engineering, Seoul National University, Seoul, Republic of Korea
1 shared publication - Dongsu Seo
Department of Electrical and Computer Engineering, and Applied Superconductivity Center, Electric Power Research Institute, Seoul National University, Seoul, Republic of Korea
1 shared publication - Gayoung Park
Department of Electrical and Computer Engineering and SNU Electric Power Research Institute, Seoul National University, Seoul, South Korea
1 shared publication
Latest Publications
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (4) , 4667-4679
Inverter Loss Reduction Method of Air Conditioners With Adjustable DC-Link Voltage Control and Six-Step Operation
This article proposes a control method for a two-stage power conversion system of a residential air conditioner drivetrain to enhance power density and reduce the hardware cost of the converters. In hardware design, the heatsink is determined based on the rated operating point, where the maximum loss occurs. When the motor operates at its rated operating point, the converter loss can be minimized using six-step operation. Compared to the existing six-step operation methods to reduce switching device losses, the proposed control method utilizes the dc-link voltage and the phase angle of the voltage vector as 2 degrees of freedom for control, which enables independent control of the dq-axis current, thus enabling optimal operation, such as maximum torque per ampere. However, in the low-speed operation region, where efficiency is critical for the energy efficiency grade, linear modulation should be applied. The proposed method addresses a seamless transition between linear modulation in light load and six-step operation in heavy load. The validity of the proposed method is verified through experiments on a 7 kW drivetrain system of a residential air conditioner.
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (4) , 4667-4679
Inverter Loss Reduction Method of Air Conditioners With Adjustable DC-Link Voltage Control and Six-Step Operation
This article proposes a control method for a two-stage power conversion system of a residential air conditioner drivetrain to enhance power density and reduce the hardware cost of the converters. In hardware design, the heatsink is determined based on the rated operating point, where the maximum loss occurs. When the motor operates at its rated operating point, the converter loss can be minimized using six-step operation. Compared to the existing six-step operation methods to reduce switching device losses, the proposed control method utilizes the dc-link voltage and the phase angle of the voltage vector as 2 degrees of freedom for control, which enables independent control of the dq-axis current, thus enabling optimal operation, such as maximum torque per ampere. However, in the low-speed operation region, where efficiency is critical for the energy efficiency grade, linear modulation should be applied. The proposed method addresses a seamless transition between linear modulation in light load and six-step operation in heavy load. The validity of the proposed method is verified through experiments on a 7 kW drivetrain system of a residential air conditioner.
- Open Access
- 27 September 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 172
A supercapacitor size minimization and energy management strategy for E-STATCOM connected to weak grid
- 27 September 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 172
Open AccessA supercapacitor size minimization and energy management strategy for E-STATCOM connected to weak grid
- 10 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (7) , 1-11
Equivalent Circuit Extraction of MI-HTS Coil Including High-Frequency Region for Electromagnetic Transient Simulation With Voltage-Source Converter
Combining metal-insulation high-temperature superconductor (MI-HTS), power electronics presents a promising potential to implement reliable magnetic energy storage systems. A modern power converter, typically implemented as a voltage-source converter (VSC), utilizes power semiconductors with switching frequencies ranging from several kHz to hundreds of kHz. From a VSC design perspective, analyzing the current flowing into power semiconductors at the microsecond timescale is essential to prevent converter failure due to overcurrent. Thus, to reduce the risk of operation failure of VSC, it is crucial to simulate the operation of VSC with MI-HTS not only the long-term behavior but also the short-term dynamics before commissioning. This article presents a practical method to develop an equivalent circuit of MI-HTS, enabling the replication of its current response at the microsecond timescale within electromagnetic transient simulations. This circuit can be used to verify the operation of MI-HTS and VSC, including control algorithms, by considering characteristics of leakage currents in MI-HTS under pulsed voltage from the VSC. The proposed method utilizes measured frequency response data and a rational approximation algorithm to extract an equivalent circuit. The proposed procedure is validated through a comparison of simulated and experimental results from closed-loop current control of a 37.2 mH MI-HTS coil driven by a VSC with a switching frequency of 2 kHz.
- 10 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (7) , 1-11
Equivalent Circuit Extraction of MI-HTS Coil Including High-Frequency Region for Electromagnetic Transient Simulation With Voltage-Source Converter
Combining metal-insulation high-temperature superconductor (MI-HTS), power electronics presents a promising potential to implement reliable magnetic energy storage systems. A modern power converter, typically implemented as a voltage-source converter (VSC), utilizes power semiconductors with switching frequencies ranging from several kHz to hundreds of kHz. From a VSC design perspective, analyzing the current flowing into power semiconductors at the microsecond timescale is essential to prevent converter failure due to overcurrent. Thus, to reduce the risk of operation failure of VSC, it is crucial to simulate the operation of VSC with MI-HTS not only the long-term behavior but also the short-term dynamics before commissioning. This article presents a practical method to develop an equivalent circuit of MI-HTS, enabling the replication of its current response at the microsecond timescale within electromagnetic transient simulations. This circuit can be used to verify the operation of MI-HTS and VSC, including control algorithms, by considering characteristics of leakage currents in MI-HTS under pulsed voltage from the VSC. The proposed method utilizes measured frequency response data and a rational approximation algorithm to extract an equivalent circuit. The proposed procedure is validated through a comparison of simulated and experimental results from closed-loop current control of a 37.2 mH MI-HTS coil driven by a VSC with a switching frequency of 2 kHz.