Nadia D'ALessandro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nadia D'ALessandro has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Arianna Menciassi
The BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
2 shared publications - Angela Peloso
Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
1 shared publication - Elena De Momi
Politecnico di Milano
1 shared publication - Izadyar Tamadon
Faculty of Engineering Technology, University of Twente, Enschede, the Netherlands
1 shared publication - Selene Tognarelli
BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
1 shared publication - Xiu Zhang
Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Italy
1 shared publication
Latest Publications
- Open Access
- 25 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. PP (10834435) , 1-12
Robotic Steerable Sheath for Left Atrial Appendage Occlusion
Atrial fibrillation, the most common cardiac arrhythmia, increases stroke risk due to clot formation in the left atrial appendage (LAA), where over 90% of thrombi originate. Left atrial appendage occlusion (LAAO) reduces this risk by mechanically sealing the LAA through an occluder. A key challenge is achieving coaxial alignment of the delivery sheath with the LAA, which varies in shape and orientation among subjects. Fixed-curve sheaths lack adaptability, while steerable sheaths improve alignment but still expose operators to fluoroscopic radiation. This study introduces the first robotic steerable delivery sheath (SDS) for LAAO. The SDS incorporates a notched Nitinol tip with two bending segments, providing three steering degrees of freedom, rotation, and translation, all controlled remotely through motorized actuation. Bench-top experiments confirmed superior dexterity and reachable workspace compared to existing delivery sheaths. A phantom-based validation with 17 users demonstrated successful teleoperated coaxial alignment with the LAA. Quantitative evaluation showed high accuracy, with mean angular and positional errors of 5.52$^{\circ }$ and 1.99 mm for the central axis, and 5.00$^{\circ }$ and 2.33 mm for implant depth, respectively. These findings support the feasibility of robotic-assisted LAAO, with the potential to enhance procedural precision while reducing radiation exposure for operators.
- 25 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. PP (10834435) , 1-12
Open AccessRobotic Steerable Sheath for Left Atrial Appendage Occlusion
Atrial fibrillation, the most common cardiac arrhythmia, increases stroke risk due to clot formation in the left atrial appendage (LAA), where over 90% of thrombi originate. Left atrial appendage occlusion (LAAO) reduces this risk by mechanically sealing the LAA through an occluder. A key challenge is achieving coaxial alignment of the delivery sheath with the LAA, which varies in shape and orientation among subjects. Fixed-curve sheaths lack adaptability, while steerable sheaths improve alignment but still expose operators to fluoroscopic radiation. This study introduces the first robotic steerable delivery sheath (SDS) for LAAO. The SDS incorporates a notched Nitinol tip with two bending segments, providing three steering degrees of freedom, rotation, and translation, all controlled remotely through motorized actuation. Bench-top experiments confirmed superior dexterity and reachable workspace compared to existing delivery sheaths. A phantom-based validation with 17 users demonstrated successful teleoperated coaxial alignment with the LAA. Quantitative evaluation showed high accuracy, with mean angular and positional errors of 5.52$^{\circ }$ and 1.99 mm for the central axis, and 5.00$^{\circ }$ and 2.33 mm for implant depth, respectively. These findings support the feasibility of robotic-assisted LAAO, with the potential to enhance procedural precision while reducing radiation exposure for operators.
- 23 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. PP, 1-8
A Robotic System with Path Planning and Visual Guidance for Teleoperated Left Atrial Appendage Closure
Percutaneous Left Atrial Appendage Closure (LAAC) is a minimally invasive procedure to prevent thromboembolic events in atrial fibrillation patients. The procedure's success relies on precise navigation and occluder deployment, which is challenged by sheath movement in the dynamic cardiac environment, procedural complexity, and prolonged radiation exposure. This study introduces a robotic-assisted navigation system for LAAC procedure, integrating a dedicated steerable sheath, customed planning algorithms, and an intuitive teleoperation interface. The path-planning framework generates collision-free routes based on patient-specific anatomy, adjusting for deviations in real-time. The teleoperation interface comprises a digital replica of the patient's anatomy with real-time visual feedback to the user for precise and intuitive navigation. Bench-top validation demonstrated that navigation guidance reduced target position error by $2.03\%$ with the planner and $2.85\%$ with the replanner, compared to free navigation without planning assistance. Planning and replanning strategies also reduced collisions with cardiac structures, highlighting the platform's potential to improve procedural precision and safety.
- 23 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. PP, 1-8
A Robotic System with Path Planning and Visual Guidance for Teleoperated Left Atrial Appendage Closure
Percutaneous Left Atrial Appendage Closure (LAAC) is a minimally invasive procedure to prevent thromboembolic events in atrial fibrillation patients. The procedure's success relies on precise navigation and occluder deployment, which is challenged by sheath movement in the dynamic cardiac environment, procedural complexity, and prolonged radiation exposure. This study introduces a robotic-assisted navigation system for LAAC procedure, integrating a dedicated steerable sheath, customed planning algorithms, and an intuitive teleoperation interface. The path-planning framework generates collision-free routes based on patient-specific anatomy, adjusting for deviations in real-time. The teleoperation interface comprises a digital replica of the patient's anatomy with real-time visual feedback to the user for precise and intuitive navigation. Bench-top validation demonstrated that navigation guidance reduced target position error by $2.03\%$ with the planner and $2.85\%$ with the replanner, compared to free navigation without planning assistance. Planning and replanning strategies also reduced collisions with cardiac structures, highlighting the platform's potential to improve procedural precision and safety.