    Summer indoor thermal-humidity environment and thermal comfort of older adults in renovated nursing homes: a case study in Changsha, China

    by Fupeng Zhang, Lei Shi, Ying Zhang, Simian Liu, Meizhen Long, Wenqian Jiang

    With the increasing demand for urban building stock renewal and elderly care facilities, nursing homes renovated from existing buildings have become increasingly common in hot-summer and cold-winter regions. However, whether their indoor thermal-humidity environments can meet the comfort and health needs of older adults remains insufficiently investigated. This study selected three typical renovated nursing homes in Changsha, China, as case buildings. Field measurements, subjective questionnaire surveys, and thermal comfort model analysis were conducted to investigate the summer indoor thermal-humidity environment in bedrooms and the thermal comfort requirements of older adults. The results show that indoor temperatures in the three nursing homes were higher than the comfort range to varying degrees in summer. The relative humidity generally remained within the allowable range of relevant standards, although periodic high-humidity conditions occurred in some rooms. The questionnaire results showed that 34.7% of the respondents perceived the indoor thermal comfort as neutral, while the overall dissatisfaction rate with the indoor physical environment was 12.8%. The thermal comfort model analysis indicated that the measured summer neutral temperature in the nursing homes in Changsha was 27.8 °C, which was 1.5 °C higher than the neutral temperature predicted by the PMV model. The actual 80% acceptable thermal comfort temperature range for older adults was 25.7 °C–29.9 °C, which was higher than the predicted range of 23.5 °C–27.7 °C. The summer thermal expectation temperature was 28.3 °C. These findings suggest that older adults in Changsha have developed a certain degree of thermal adaptation to relatively high summer temperatures, and that the conventional PMV model may underestimate their acceptability of warmer indoor environments. Therefore, summer thermal environment optimization in renovated nursing homes should comprehensively consider the thermal insulation of building envelopes, shading and ventilation, air-conditioning dehumidification, and individual adaptive behaviors of older adults. This study provides a reference for the thermal environment optimization design and operation management of existing buildings converted into nursing homes in hot-summer and cold-winter regions.

  • Open Access

    A Study on Indoor Air Quality in Traditional Earthen Residences of Western Hunan: Field Survey and Passive Mitigation Strategies

    by Fupeng Zhang, Lei Shi, Ying Zhang, Simian Liu, Meizhen Long

    In the western Hunan region, the fire pit serves as the primary space for heating, receiving guests, and sacrificial ceremonies. However, the prolonged use of wood as the main fuel for the fire pit poses a significant threat to indoor air quality and the health of residents. This study conducts field monitoring and evaluation of indoor air quality in traditional earthen residences in Western Hunan during winter. It employs software simulation to analyze the concentration of indoor pollutants in typical earthen dwellings. Three passive mitigation strategies—adjusting window size, installing interior partitions, and setting up passive smoke exhaust systems—are proposed, and their effectiveness is validated through simulation. The results indicate that the best air circulation performance occurs when the window sill height is between 0.9 and 1.5 m, and the window sill length is between 1.5 and 2.1 m. Installing partitions increases the average concentration of indoor pollutants in the fire pit and master bedroom areas by 2.33 and 3.05 times, respectively. Installing smoke exhaust systems above the fireplace can decrease indoor pollutant concentrations by more than 70%. The findings provide effective strategies for controlling health risks caused by indoor pollutants in winter without affecting local residents’ living habits and traditional customs.