VLVo Thi Khanh Ly

Vo Thi Khanh Ly

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vo Thi Khanh Ly has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electrochemical sensing of sildenafil in pharmaceutical formulations using an (S,N)-doped reduced graphene oxide-modified electrode

    by Nguyen Quang Man, Ngo Thi Thanh Xuan, Vo Thi Khanh Ly, Le Van Thanh Son, Le Duc Anh, Le Thi Hong Phong, Nguyen Hai Phong, Pham Khac Lieu, Le Lam Son, Dinh Quang Khieu

    In this work, (S,N)-co-doped reduced graphene oxide ((S,N)-rGO) was successfully synthesized via thermal treatment and thoroughly characterized by X-ray diffraction, high-resolution transmission electron microscopy, elemental mapping, photoluminescence, and Raman spectroscopy, confirming the successful incorporation of nitrogen and sulfur into the graphene framework. The obtained (S,N)-rGO was used to modify a glassy carbon electrode for the electrochemical determination of sildenafil (SDN). The modified electrode exhibited enhanced electrocatalytic activity toward SDN oxidation, providing a well-defined current response. Under optimized conditions, the sensor showed a good linear relationship between peak current and SDN concentration in the range of 0.25–4.98 µM, with a low limit of detection of 0.24 µM and a limit of quantification of 0.78 µM. The proposed sensor demonstrated satisfactory repeatability, reproducibility, and stability, as well as good selectivity in the presence of potential interfering substances. The applicability of the method was validated by the determination of SDN in pharmaceutical samples. The results were in good agreement with those from high-performance liquid chromatography, indicating that the proposed electrochemical method is reliable and suitable for practical analysis.

  • Open Access

    Electrochemical determination of ciprofloxacin using a MIL-101/reduced graphene oxide-modified electrode

    by Nguyen Quang Man, Nguyen Ngoc Nghia, Nguyen Vinh Phu, Vo Thi Khanh Ly, Le Lam Son, Pham Khac Lieu, Le Thi Hong Phong, Nguyen Dinh Luyen, Dinh Quang Khieu

    An electrochemical sensor for the determination of ciprofloxacin (CPR) was developed using a glassy carbon electrode modified with MIL-101/reduced graphene oxide (MIL-101/rGO). MIL-101/rGO was synthesized via a facile ultrasonic-assisted method and characterized by various physicochemical techniques. The synergistic combination of MIL-101 with rGO significantly enhanced the electrocatalytic activity toward CPR oxidation. The electrochemical behavior of CPR on the MIL-101/rGO-modified electrode was systematically investigated using cyclic voltammetry and differential pulse voltammetry. Under optimized experimental conditions, the proposed sensor exhibited a linear response over 0.25–9.41 µM and a detection limit of 0.11 µM for CPR determination. The sensor also demonstrated good selectivity, satisfactory repeatability, and long-term stability. Furthermore, the method’s practical applicability was validated by the determination of CPR in pharmaceutical samples, yielding acceptable recoveries. These results indicate that the MIL-101/rGO-modified electrode provides a promising and efficient platform for the electrochemical sensing of CPR in pharmaceutical and environmental analysis.


  • Open Access

    MIL-101 (Cr): Synthesis and simultaneous electrochemical determination of uric acid and theophylline using MIL-101 (Cr) modified electrode

    by Nguyen Ngoc Nghia, Nguyen Quang Man, Hoa Thi Le, Nguyen Duc Vu Quyen, Ho Van Minh Hai, Nguyen Chi Bao, Son Van Thanh Le, Trinh Ngoc Dat, Le Thi Hong Phong, Vo Thi Khanh Ly, et al.

    This paper presents the synthesis of metal-organic frameworks in the MIL (Materials Institute Lavoisier) series using a hydrothermal process. Our research revealed that MIL-101 was formed at the early synthetic stage, approximately eight hours, followed by the formation of MIL-88B with further prolongation of the hydrothermal time. The morphology of the octahedral shape for MIL-101 transformed into the rode-like shape of MIL-88B, accompanied by a decrease in the surface area. The electrode modified by MIL-101 exhibited electrochemical activity towards uric acid and theophylline better than that modified by MIL-88B. We also developed a glassy carbon electrode (GCE) modified by MIL-101 for simultaneous uric acid and theophylline detection. Electrochemical sensing features were investigated using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and differential pulse voltammetry (DPV). The calibration curves for uric acid and theophylline were obtained in the 0.20–1.69 µM range. The detection limits (3σ) were 0.12 µM and 0.13 µM for uric acid and theophylline, respectively. Notably, using a standard addition method, the present approach was used to determine URI and THE in urine samples, achieving exceptional recoveries. The proposed electrochemical sensor also revealed good reproducibility, repeatability, and long-term stability.