Daiki Kobayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daiki Kobayashi has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Hiroaki Hayashi
College of Transdisciplinary Sciences for Innovation Kanazawa University Kanazawa Ishikawa Japan
2 shared publications - Natsumi Kimoto
Department of Radiological Science, Faculty of Health Sciences, Junshin Gakuen University, 1-1-1 Chikushigaoka, Fukuoka, Minami-Ku, 815-8510, Japan
2 shared publications - Rina Nishigami
Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan
2 shared publications - Takashi Asahara
Department of Radiological Technology, Faculty of Health Sciences Okayama University Okayama Japan
2 shared publications - Akitoshi Katsumata
Department of Oral Radiology, School of Dentistry, Asahi University, Mizuho-shi, Japan
1 shared publication - Fumiyo Higaki
Department of Radiology, Medical Development Field, Okayama University, 2-5-1 Shikata-cho, Kita-Ku, Okayama, 700-8558, Japan
1 shared publication
Latest Publications
- Open Access
- 23 June 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 236, 112768
An algorithm to calculate physical density of biomedical objects having 3 ≤ Zeff ≤ 20: an application study using clinical photon-counting computed tomography equipment
- 23 June 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 236, 112768
Open AccessAn algorithm to calculate physical density of biomedical objects having 3 ≤ Zeff ≤ 20: an application study using clinical photon-counting computed tomography equipment
- 26 March 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (7) , 075023
A blurring correction method suitable to analyze quantitative x-ray images derived from energy-resolving photon counting detector
Objective. The purpose of this study is to propose a novel blurring correction method that enables accurate quantitative analysis of the object edge when using energy-resolving photon counting detectors (ERPCDs). Although the ERPCDs have the ability to generate various quantitative analysis techniques, such as the derivations of effective atomic number ( Z eff ) and bone mineral density values, at the object edge in these quantitative images, accurate quantitative information cannot be obtained. This is because image blurring prevents the gathering of accurate primary x-ray attenuation information. Approach. We developed the following procedure for blurring correction. A 5 × 5 pixels masking region was set as the processing area, and the pixels affected by blurring were extracted from the analysis of pixel value distribution. The blurred pixel values were then corrected to the proper values estimated by analyzing minimum and/or maximum values in the set mask area. The suitability of our correction method was verified by a simulation study and an experiment using a prototype ERPCD. Main results . When Z eff image of aluminum objects ( Z eff = 13) were analyzed without applying our correction method, regardless of raw data or correction data applying a conventional edge enhancement method, the proper Z eff values could not be derived for the object edge. In contrast, when applying our correction method, 82% of pixels affected by blurring were corrected and the proper Z eff values were calculated for those pixels. As a result of investigating the applicability limits of our method through simulation, it was proven that it works effectively for objects with 4 × 4 pixels or more. Significance . Our method is effective in correcting image blurring when the quantitative image is calculated based on multiple images. It will become an in-demand technology for putting a quantitative diagnosis into actual medical examinations.
- 26 March 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (7) , 075023
A blurring correction method suitable to analyze quantitative x-ray images derived from energy-resolving photon counting detector
Objective. The purpose of this study is to propose a novel blurring correction method that enables accurate quantitative analysis of the object edge when using energy-resolving photon counting detectors (ERPCDs). Although the ERPCDs have the ability to generate various quantitative analysis techniques, such as the derivations of effective atomic number ( Z eff ) and bone mineral density values, at the object edge in these quantitative images, accurate quantitative information cannot be obtained. This is because image blurring prevents the gathering of accurate primary x-ray attenuation information. Approach. We developed the following procedure for blurring correction. A 5 × 5 pixels masking region was set as the processing area, and the pixels affected by blurring were extracted from the analysis of pixel value distribution. The blurred pixel values were then corrected to the proper values estimated by analyzing minimum and/or maximum values in the set mask area. The suitability of our correction method was verified by a simulation study and an experiment using a prototype ERPCD. Main results . When Z eff image of aluminum objects ( Z eff = 13) were analyzed without applying our correction method, regardless of raw data or correction data applying a conventional edge enhancement method, the proper Z eff values could not be derived for the object edge. In contrast, when applying our correction method, 82% of pixels affected by blurring were corrected and the proper Z eff values were calculated for those pixels. As a result of investigating the applicability limits of our method through simulation, it was proven that it works effectively for objects with 4 × 4 pixels or more. Significance . Our method is effective in correcting image blurring when the quantitative image is calculated based on multiple images. It will become an in-demand technology for putting a quantitative diagnosis into actual medical examinations.