Rina Nishigami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rina Nishigami has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Hiroaki Hayashi
College of Transdisciplinary Sciences for Innovation Kanazawa University Kanazawa Ishikawa Japan
3 shared publications - Natsumi Kimoto
Department of Radiological Science, Faculty of Health Sciences, Junshin Gakuen University, 1-1-1 Chikushigaoka, Fukuoka, Minami-Ku, 815-8510, Japan
3 shared publications - Takashi Asahara
Department of Radiological Technology, Faculty of Health Sciences Okayama University Okayama Japan
3 shared publications - Daiki Kobayashi
Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan
2 shared publications - Mana Mitani
Division of Radiological Technology, Medical Support Department, Okayama University Hospital, 2-5-1 Shikata-cho, Kita-Ku, Okayama, 700-8558, Japan
2 shared publications - Noriaki Akagi
Division of Radiological Technology, Medical Support Department, Okayama University Hospital, 2-5-1 Shikata-cho, Kita-Ku, Okayama, 700-8558, Japan
2 shared publications
Latest Publications
- Open Access
- 23 June 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 236, 112768
An algorithm to calculate physical density of biomedical objects having 3 ≤ Zeff ≤ 20: an application study using clinical photon-counting computed tomography equipment
- 23 June 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 236, 112768
Open AccessAn algorithm to calculate physical density of biomedical objects having 3 ≤ Zeff ≤ 20: an application study using clinical photon-counting computed tomography equipment
- Open Access
- 22 September 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (6) , 378-386
Applicability of Effective Atomic Number (Z eff) Image Analysis of Coronary Plaques Measured With Photon- Counting Computed Tomography
Objective: Coronary computed tomography (CT) allows the assessment of cardiovascular risk by imaging calcified plaques in coronary arteries. Because photon-counting CT (PC-CT) can analyze the effective atomic number (Z eff) of the subject, it is expected to be applied to the analysis of plaque components. The purpose of this study was to investigate the applicability of plaque analysis based on Z eff images with continuous gradation. Methods: Z eff images were generated from virtual monoenergetic images (VMIs) obtained by PC-CT. Z eff values were derived from the difference between linear attenuation coefficients (μ) at low and high energies using an in-house program. Coronary CT images of 64 plaques in 10 patients were analyzed. The Z eff score, calculated as the sum of Z eff values within the plaque region, was calculated and compared with the conventional Agatston score and mean coronary artery calcium (CAC) score. Results: The systematic uncertainty of Z eff images was estimated to be ±0.08. The Z eff score of actual patient data showed strong positive correlations with the conventional Agatston and mean CAC scores. The Z eff score uses all voxel data in the plaque area, whereas conventional scores consider only data from voxels with a CT value >130. We found that the conventional scores excluded 39% of the plaque area, and the Z eff score permitted the analysis of low- and high-density plaques. Conclusions: Z eff imaging was shown to be applicable to plaque analysis that reflects the entire plaque volume. This study demonstrated its technical feasibility as a compositional analysis method using the Z eff image.
- 22 September 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (6) , 378-386
Open AccessApplicability of Effective Atomic Number (Z eff) Image Analysis of Coronary Plaques Measured With Photon- Counting Computed Tomography
Objective: Coronary computed tomography (CT) allows the assessment of cardiovascular risk by imaging calcified plaques in coronary arteries. Because photon-counting CT (PC-CT) can analyze the effective atomic number (Z eff) of the subject, it is expected to be applied to the analysis of plaque components. The purpose of this study was to investigate the applicability of plaque analysis based on Z eff images with continuous gradation. Methods: Z eff images were generated from virtual monoenergetic images (VMIs) obtained by PC-CT. Z eff values were derived from the difference between linear attenuation coefficients (μ) at low and high energies using an in-house program. Coronary CT images of 64 plaques in 10 patients were analyzed. The Z eff score, calculated as the sum of Z eff values within the plaque region, was calculated and compared with the conventional Agatston score and mean coronary artery calcium (CAC) score. Results: The systematic uncertainty of Z eff images was estimated to be ±0.08. The Z eff score of actual patient data showed strong positive correlations with the conventional Agatston and mean CAC scores. The Z eff score uses all voxel data in the plaque area, whereas conventional scores consider only data from voxels with a CT value >130. We found that the conventional scores excluded 39% of the plaque area, and the Z eff score permitted the analysis of low- and high-density plaques. Conclusions: Z eff imaging was shown to be applicable to plaque analysis that reflects the entire plaque volume. This study demonstrated its technical feasibility as a compositional analysis method using the Z eff image.
- 26 March 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (7) , 075023
A blurring correction method suitable to analyze quantitative x-ray images derived from energy-resolving photon counting detector
Objective. The purpose of this study is to propose a novel blurring correction method that enables accurate quantitative analysis of the object edge when using energy-resolving photon counting detectors (ERPCDs). Although the ERPCDs have the ability to generate various quantitative analysis techniques, such as the derivations of effective atomic number ( Z eff ) and bone mineral density values, at the object edge in these quantitative images, accurate quantitative information cannot be obtained. This is because image blurring prevents the gathering of accurate primary x-ray attenuation information. Approach. We developed the following procedure for blurring correction. A 5 × 5 pixels masking region was set as the processing area, and the pixels affected by blurring were extracted from the analysis of pixel value distribution. The blurred pixel values were then corrected to the proper values estimated by analyzing minimum and/or maximum values in the set mask area. The suitability of our correction method was verified by a simulation study and an experiment using a prototype ERPCD. Main results . When Z eff image of aluminum objects ( Z eff = 13) were analyzed without applying our correction method, regardless of raw data or correction data applying a conventional edge enhancement method, the proper Z eff values could not be derived for the object edge. In contrast, when applying our correction method, 82% of pixels affected by blurring were corrected and the proper Z eff values were calculated for those pixels. As a result of investigating the applicability limits of our method through simulation, it was proven that it works effectively for objects with 4 × 4 pixels or more. Significance . Our method is effective in correcting image blurring when the quantitative image is calculated based on multiple images. It will become an in-demand technology for putting a quantitative diagnosis into actual medical examinations.
- 26 March 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (7) , 075023
A blurring correction method suitable to analyze quantitative x-ray images derived from energy-resolving photon counting detector
Objective. The purpose of this study is to propose a novel blurring correction method that enables accurate quantitative analysis of the object edge when using energy-resolving photon counting detectors (ERPCDs). Although the ERPCDs have the ability to generate various quantitative analysis techniques, such as the derivations of effective atomic number ( Z eff ) and bone mineral density values, at the object edge in these quantitative images, accurate quantitative information cannot be obtained. This is because image blurring prevents the gathering of accurate primary x-ray attenuation information. Approach. We developed the following procedure for blurring correction. A 5 × 5 pixels masking region was set as the processing area, and the pixels affected by blurring were extracted from the analysis of pixel value distribution. The blurred pixel values were then corrected to the proper values estimated by analyzing minimum and/or maximum values in the set mask area. The suitability of our correction method was verified by a simulation study and an experiment using a prototype ERPCD. Main results . When Z eff image of aluminum objects ( Z eff = 13) were analyzed without applying our correction method, regardless of raw data or correction data applying a conventional edge enhancement method, the proper Z eff values could not be derived for the object edge. In contrast, when applying our correction method, 82% of pixels affected by blurring were corrected and the proper Z eff values were calculated for those pixels. As a result of investigating the applicability limits of our method through simulation, it was proven that it works effectively for objects with 4 × 4 pixels or more. Significance . Our method is effective in correcting image blurring when the quantitative image is calculated based on multiple images. It will become an in-demand technology for putting a quantitative diagnosis into actual medical examinations.