NSNidhi Sharma

Nidhi Sharma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nidhi Sharma has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative evaluation of postfabrication thickness of thermoformed 3 mm and 4 mm mouthguards on crowded and proclined malocclusion models: An in vitro study

    by Ritesh Kalaskar, Nidhi Sharma, Ashita Kalaskar

    Purpose: To evaluate and compare the postfabrication thickness (PFT) of thermoformed mouthguards fabricated from 3 mm and 4 mm ethylene-vinyl acetate (EVA) sheets on crowded and proclined dental models. Materials and Methods: An in-vitro study was conducted using 20 mouthguards fabricated on dental stone models with crowded and proclined maxillary anterior teeth. Pressure-molded mouthguards were made using 3 mm and 4 mm EVA sheets. PFT was measured at standardized labial, buccal, and sulcus regions using an Iwanson caliper. Statistical analysis was performed using ANOVA, Tukey’s post hoc test, and unpaired t -test ( P < 0.05). Results: Significant thickness reduction was observed in both 3 mm and 4 mm mouthguards. In crowded dentition, 42%–61% thinning occurred at labial surfaces and 53%–71% at the sulcus, while proclined dentition showed 40%–60% and 51%–67% thinning, respectively. Maximum thinning occurred at canines, whereas molars showed the least reduction. Conclusion: Thermoforming causes substantial reduction in mouthguard thickness, particularly in anterior regions. Dental alignment influences final thickness, and clinicians should consider postfabrication thinning when selecting EVA sheet thickness to ensure adequate protection.

  • Open Access

    Cognitive abilities in 4–12-year-old children using the number cancellation test: A cross-sectional normative study

    by Nidhi Sharma, Ritesh Kalaskar, Avani Ramesh Doiphode, Utkarsha Kadam, Snehal Jagtap

    Background: Safe discharge after nitrous oxide–oxygen conscious sedation in children requires ensuring full psychomotor and cognitive recovery. The number cancellation test (NCT) can serve as an objective tool to assess these functions. However, normative data for Indian children are lacking. Aim: The aim of the study was to evaluate the cognitive abilities of 4–12-year-old children using the NCT and establish age-wise normative data under normal (nonsedated) conditions. Materials and Methods: A cross-sectional study was conducted among 246 healthy children aged 4–12 years, divided into three groups: Group I (4–6 years), Group II (7–9 years), and Group III (10–12 years). Each child completed the NCT three times, and the time taken, scores, errors, and pattern (vertical, horizontal, or random) were recorded. Data were analyzed using the Kruskal–Wallis and Chi-square tests ( P < 0.05). Results: Children in Group III completed the test in the least time (231.9 s, ≈4 min) and achieved higher average scores (119.3) compared to Group I (604.3 s, ≈10 min; 109 points). The differences in time, score, and pattern were statistically significant among age groups ( P < 0.001). Conclusion: Cognitive efficiency improves with age, as older children complete the NCT faster and with greater accuracy. These normative data may serve as baseline references for evaluating recovery following nitrous oxide conscious sedation.

  • Open Access

    Stress Distribution Pattern of a Calculated Standardized Force on Primary Second Molar Restored with 3D-printed Resin NextDent Crown and Prefabricated Zirconia Crown: A 3D Finite Element Analysis

    by Ritesh R Kalaskar, Utkarsha S Kadam, Nidhi Sharma, Snehal D Jagtap

    Restoring grossly destructed primary molars requires esthetic and durable materials that can withstand masticatory forces. Although preformed zirconia crowns are strong and durable, they require extensive tooth preparation and are brittle. The three-dimensional (3D)-printed resin NextDent crowns are nonbrittle and offer better or similar esthetic alternatives, but their ability to withstand intraoral stresses remains untested. Therefore, a 3D finite element analysis (FEA) study was planned to compare the stress distribution on primary molars restored with custom-made 3D-printed resin NextDent crowns and preformed zirconia crowns. The study design employed two finite element models, with the endodontically restored primary mandibular second molar—one restored with a 3D-printed resin NextDent crown and the other with a preformed zirconia crown. The finite element models were exported to ANSYS software and subjected to a maximum load of 500 N. The von Mises stress distribution analysis shows that the 3D-printed resin NextDent crown exhibits a higher maximum stress of 383.2 MPa on the crown, compared to 351.12 MPa for the zirconia crown. The 3D-printed resin NextDent crown can be used as an alternative to prefabricated zirconia crown for full coronal restoration of primary teeth. 3D-printed resin crowns offer high esthetic value with precise customization, require minimal tooth preparation, and are cost-effective, making them a practical and accessible option for full coronal restoration in pediatric patients. Kalaskar RR, Kadam US, Sharma N, et al. Stress Distribution Pattern of a Calculated Standardized Force on Primary Second Molar Restored with 3D-printed Resin NextDent Crown and Prefabricated Zirconia Crown: A 3D Finite Element Analysis. Int J Clin Pediatr Dent 2025;18(S-1):S35–S39.


  • Open Access

    Comparative evaluation of qualitative and quantitative wear of 3D-printing materials and zirconia against primary tooth enamel: An in vitro study

    by Ritesh Kalaskar, Nidhi Sharma, Utkarsha Kadam, Snehal Jagtap

    Aim: This study aimed to address the gap in existing literature by evaluating the qualitative and quantitative wear of two three-dimensional (3D) printing materials against primary tooth enamel, in comparison with zirconia, a widely used esthetic crown material. Methods: Eighteen extracted primary canines were used as antagonists, and six blocks each of two 3D printing resins (Shining 3D and NextDent) and zirconia were fabricated. Wear testing was performed using a reciprocating tribometer under a 40 N load at 1.5 Hz with a 4 mm stroke length for 60,000 cycles. Pre- and post-test digital scans were analyzed in Geomagic Software using a superimposition technique to calculate volumetric wear, and surface changes were examined using scanning electron microscopy. Statistical analysis was conducted using one-way ANOVA for quantitative comparison. Results: Shining 3D demonstrated the greatest material wear (0.51 mm³), followed by NextDent (0.27 mm³), while zirconia exhibited the least (0.13 mm³). Conversely, zirconia caused the highest antagonist wear (0.25 mm³), followed by NextDent (0.17 mm³) and Shining 3D (0.12 mm³), although these differences were not statistically significant. Distinct wear patterns were observed for each material. Conclusions: Within the limitations of this in vitro study, NextDent exhibited greater wear resistance than Shining 3D. Both 3D-printing resins produced less antagonist enamel wear than zirconia, underscoring their potential as promising alternatives in pediatric restorative dentistry. Further studies employing diverse materials and standardized protocols are required to validate these findings and enhance clinical translation.

  • Open Access

    Evaluation of acenes as potential acceptors in thermally activated delayed fluorescence emitters and the promise of a phenoxazine–naphthalene emitter for OLEDs

    by Oliver S. Lee, Nidhi Sharma, Tomas Matulaitis, Alexandra M. Z. Slawin, Yoann Olivier, Ifor D. W. Samuel, Malte C. Gather, Eli Zysman-Colman

    Thermally activated delayed fluorescence (TADF) is one of the most promising technologies for harvesting triplet excitons in all-organic emitters, a property that is essential for achieving high efficiency in devices. Compounds that operate via this mechanism for emission typically rely on a combination of electron donating and accepting moieties separated by an aromatic bridge. Here we demonstrate that although naphthalene is underutilised as an acceptor, it can nonetheless be used in a donor–acceptor TADF emitter when coupled to two phenoxazines in the 1- and 4-positions. The compound 1,4-PXZ-Nap-PXZ emits at 508 nm, has a photoluminescence quantum yield of 48% and a delayed lifetime of 22.7 ms in a 20 wt% doped film in 1,3-bis(N-carbazolyl)benzene (mCP). An organic light-emitting diode (OLED) using this emitter showed a maximum external quantum efficiency (EQEmax) of 11% and green emission at λEL of 505 nm, demonstrating for the first time the potential of naphthalene-acceptor based emitters for devices. Finally, we have demonstrated by way of a density functional theory (DFT) study why naphthalene alone amongst linear acenes is suitable for this role.


  • Optimization of FSW Process Parameters During Joining of Al to Cu Using Taguchi-Based GA

    by Nidhi Sharma, Pankul Goel, M. A. Wahid, Zahid. A. Khan, Arshad Noor Siddiquee