Snehal Jagtap
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Snehal Jagtap has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Nidhi Sharma
Department of Paediatric and Preventive Dentistry, Government Dental College and Hospital, Nagpur, Maharashtra, India
2 shared publications - Ritesh Kalaskar
1,2Department of Pediatric and Preventive Dentistry, Government Dental College and Hospital, Nagpur, Maharashtra, India
2 shared publications - Utkarsha Kadam
1–4Department of Pediatric and Preventive Dentistry, Government Dental College and Hospital, Nagpur, Maharashtra, India
2 shared publications - Anija Ck
Department of Pediatric and Preventive Dentistry, Government Dental College & Hospital, Nagpur, Maharashtra, India
1 shared publication - Nilam Vitthalrao Honaje
Department of Pediatric and Preventive Dentistry, Government Dental College & Hospital, Nagpur, Maharashtra, India
1 shared publication - Nupur Ninawe
Department of Pediatric and Preventive Dentistry, Government Dental College & Hospital, Nagpur, Maharashtra, India
1 shared publication
Latest Publications
- Open Access
- 5 November 2025
- Published by Jaypee Brothers Medical Publishing in International Journal of Clinical Pediatric Dentistry
- Vol. 18 (S1) , S35-S39
Stress Distribution Pattern of a Calculated Standardized Force on Primary Second Molar Restored with 3D-printed Resin NextDent Crown and Prefabricated Zirconia Crown: A 3D Finite Element Analysis
Restoring grossly destructed primary molars requires esthetic and durable materials that can withstand masticatory forces. Although preformed zirconia crowns are strong and durable, they require extensive tooth preparation and are brittle. The three-dimensional (3D)-printed resin NextDent crowns are nonbrittle and offer better or similar esthetic alternatives, but their ability to withstand intraoral stresses remains untested. Therefore, a 3D finite element analysis (FEA) study was planned to compare the stress distribution on primary molars restored with custom-made 3D-printed resin NextDent crowns and preformed zirconia crowns. The study design employed two finite element models, with the endodontically restored primary mandibular second molar—one restored with a 3D-printed resin NextDent crown and the other with a preformed zirconia crown. The finite element models were exported to ANSYS software and subjected to a maximum load of 500 N. The von Mises stress distribution analysis shows that the 3D-printed resin NextDent crown exhibits a higher maximum stress of 383.2 MPa on the crown, compared to 351.12 MPa for the zirconia crown. The 3D-printed resin NextDent crown can be used as an alternative to prefabricated zirconia crown for full coronal restoration of primary teeth. 3D-printed resin crowns offer high esthetic value with precise customization, require minimal tooth preparation, and are cost-effective, making them a practical and accessible option for full coronal restoration in pediatric patients. Kalaskar RR, Kadam US, Sharma N, et al. Stress Distribution Pattern of a Calculated Standardized Force on Primary Second Molar Restored with 3D-printed Resin NextDent Crown and Prefabricated Zirconia Crown: A 3D Finite Element Analysis. Int J Clin Pediatr Dent 2025;18(S-1):S35–S39.
- 5 November 2025
- Published by Jaypee Brothers Medical Publishing in International Journal of Clinical Pediatric Dentistry
- Vol. 18 (S1) , S35-S39
Open AccessStress Distribution Pattern of a Calculated Standardized Force on Primary Second Molar Restored with 3D-printed Resin NextDent Crown and Prefabricated Zirconia Crown: A 3D Finite Element Analysis
Restoring grossly destructed primary molars requires esthetic and durable materials that can withstand masticatory forces. Although preformed zirconia crowns are strong and durable, they require extensive tooth preparation and are brittle. The three-dimensional (3D)-printed resin NextDent crowns are nonbrittle and offer better or similar esthetic alternatives, but their ability to withstand intraoral stresses remains untested. Therefore, a 3D finite element analysis (FEA) study was planned to compare the stress distribution on primary molars restored with custom-made 3D-printed resin NextDent crowns and preformed zirconia crowns. The study design employed two finite element models, with the endodontically restored primary mandibular second molar—one restored with a 3D-printed resin NextDent crown and the other with a preformed zirconia crown. The finite element models were exported to ANSYS software and subjected to a maximum load of 500 N. The von Mises stress distribution analysis shows that the 3D-printed resin NextDent crown exhibits a higher maximum stress of 383.2 MPa on the crown, compared to 351.12 MPa for the zirconia crown. The 3D-printed resin NextDent crown can be used as an alternative to prefabricated zirconia crown for full coronal restoration of primary teeth. 3D-printed resin crowns offer high esthetic value with precise customization, require minimal tooth preparation, and are cost-effective, making them a practical and accessible option for full coronal restoration in pediatric patients. Kalaskar RR, Kadam US, Sharma N, et al. Stress Distribution Pattern of a Calculated Standardized Force on Primary Second Molar Restored with 3D-printed Resin NextDent Crown and Prefabricated Zirconia Crown: A 3D Finite Element Analysis. Int J Clin Pediatr Dent 2025;18(S-1):S35–S39.
- Open Access
- 15 September 2025
- Published by Jaypee Brothers Medical Publishing in International Journal of Clinical Pediatric Dentistry
- Vol. 18 (9) , 1066-1070
Comparative Evaluation of the Effect of Different Matrix Metalloproteinase Inhibitors on Shear Bond Strength between Composite and Dentin: An In Vitro Study
Matrix metalloproteinases (MMPs) degrade the hybrid layer in dentin bonding, affecting composite restoration longevity. Inhibitors like tetracyclines, chlorhexidine (CHX), and ethylenediaminetetraacetic acid (EDTA) can enhance bond strength. In vitro studies compare these inhibitors' effects on shear bond strength (SBS), aiming to improve clinical outcomes and extend restoration lifespan. This study aims to compare the effects of different MMP inhibitors on the SBS between composite and dentin using a universal testing machine. A total of 64 freshly extracted human premolars, free from cracks or defects, were collected, disinfected in 0.5% chloramine T solution, and stored in distilled water for use within 6 months. These premolars, exhibiting normal anatomy and from patients without orthodontic treatment history, were divided into four groups, including a control group. Teeth were meticulously cleaned, embedded in acrylic resin blocks, and underwent prophylaxis with pumice and water. Composite cylinder build-ups were performed on the specimens, and their SBS was measured. SBS among four different MMP inhibitors, with and without thermocycling, shows a significant difference (p = 0.003 and p < 0.001, respectively). Without thermocycling, the control group (10.97 MPa) shows the highest SBS, while 17% EDTA (5.32 MPa) showed the lowest. Similarly, with thermocycling, 2% CHX (10.97 MPa) exhibited the highest SBS, and 17% EDTA (3.92 MPa) showed the lowest. CHX emerged as the most effective MMP inhibitor, with 2% chlorhexidine showing the highest SBS in both thermocycling and nonthermocycling groups, while 17% EDTA showed the lowest. MMP inhibitors, particularly 2% chlorhexidine, help maintain improved dentin bonding durability of adhesive restorations after thermocycling. Honaje NV, Ninawe N, Anija CK, et al. Comparative Evaluation of the Effect of Different Matrix Metalloproteinase Inhibitors on Shear Bond Strength between Composite and Dentin: An In Vitro Study. Int J Clin Pediatr Dent 2025;18(9):1066-1070.
- 15 September 2025
- Published by Jaypee Brothers Medical Publishing in International Journal of Clinical Pediatric Dentistry
- Vol. 18 (9) , 1066-1070
Open AccessComparative Evaluation of the Effect of Different Matrix Metalloproteinase Inhibitors on Shear Bond Strength between Composite and Dentin: An In Vitro Study
Matrix metalloproteinases (MMPs) degrade the hybrid layer in dentin bonding, affecting composite restoration longevity. Inhibitors like tetracyclines, chlorhexidine (CHX), and ethylenediaminetetraacetic acid (EDTA) can enhance bond strength. In vitro studies compare these inhibitors' effects on shear bond strength (SBS), aiming to improve clinical outcomes and extend restoration lifespan. This study aims to compare the effects of different MMP inhibitors on the SBS between composite and dentin using a universal testing machine. A total of 64 freshly extracted human premolars, free from cracks or defects, were collected, disinfected in 0.5% chloramine T solution, and stored in distilled water for use within 6 months. These premolars, exhibiting normal anatomy and from patients without orthodontic treatment history, were divided into four groups, including a control group. Teeth were meticulously cleaned, embedded in acrylic resin blocks, and underwent prophylaxis with pumice and water. Composite cylinder build-ups were performed on the specimens, and their SBS was measured. SBS among four different MMP inhibitors, with and without thermocycling, shows a significant difference (p = 0.003 and p < 0.001, respectively). Without thermocycling, the control group (10.97 MPa) shows the highest SBS, while 17% EDTA (5.32 MPa) showed the lowest. Similarly, with thermocycling, 2% CHX (10.97 MPa) exhibited the highest SBS, and 17% EDTA (3.92 MPa) showed the lowest. CHX emerged as the most effective MMP inhibitor, with 2% chlorhexidine showing the highest SBS in both thermocycling and nonthermocycling groups, while 17% EDTA showed the lowest. MMP inhibitors, particularly 2% chlorhexidine, help maintain improved dentin bonding durability of adhesive restorations after thermocycling. Honaje NV, Ninawe N, Anija CK, et al. Comparative Evaluation of the Effect of Different Matrix Metalloproteinase Inhibitors on Shear Bond Strength between Composite and Dentin: An In Vitro Study. Int J Clin Pediatr Dent 2025;18(9):1066-1070.
- Open Access
- 30 August 2025
- Published by Contemporary Pediatric Dentistry in Contemporary Pediatric Dentistry
- Vol. 6 (2) , 149-159
Comparative evaluation of qualitative and quantitative wear of 3D-printing materials and zirconia against primary tooth enamel: An in vitro study
Aim: This study aimed to address the gap in existing literature by evaluating the qualitative and quantitative wear of two three-dimensional (3D) printing materials against primary tooth enamel, in comparison with zirconia, a widely used esthetic crown material. Methods: Eighteen extracted primary canines were used as antagonists, and six blocks each of two 3D printing resins (Shining 3D and NextDent) and zirconia were fabricated. Wear testing was performed using a reciprocating tribometer under a 40 N load at 1.5 Hz with a 4 mm stroke length for 60,000 cycles. Pre- and post-test digital scans were analyzed in Geomagic Software using a superimposition technique to calculate volumetric wear, and surface changes were examined using scanning electron microscopy. Statistical analysis was conducted using one-way ANOVA for quantitative comparison. Results: Shining 3D demonstrated the greatest material wear (0.51 mm³), followed by NextDent (0.27 mm³), while zirconia exhibited the least (0.13 mm³). Conversely, zirconia caused the highest antagonist wear (0.25 mm³), followed by NextDent (0.17 mm³) and Shining 3D (0.12 mm³), although these differences were not statistically significant. Distinct wear patterns were observed for each material. Conclusions: Within the limitations of this in vitro study, NextDent exhibited greater wear resistance than Shining 3D. Both 3D-printing resins produced less antagonist enamel wear than zirconia, underscoring their potential as promising alternatives in pediatric restorative dentistry. Further studies employing diverse materials and standardized protocols are required to validate these findings and enhance clinical translation.
- 30 August 2025
- Published by Contemporary Pediatric Dentistry in Contemporary Pediatric Dentistry
- Vol. 6 (2) , 149-159
Open AccessComparative evaluation of qualitative and quantitative wear of 3D-printing materials and zirconia against primary tooth enamel: An in vitro study
Aim: This study aimed to address the gap in existing literature by evaluating the qualitative and quantitative wear of two three-dimensional (3D) printing materials against primary tooth enamel, in comparison with zirconia, a widely used esthetic crown material. Methods: Eighteen extracted primary canines were used as antagonists, and six blocks each of two 3D printing resins (Shining 3D and NextDent) and zirconia were fabricated. Wear testing was performed using a reciprocating tribometer under a 40 N load at 1.5 Hz with a 4 mm stroke length for 60,000 cycles. Pre- and post-test digital scans were analyzed in Geomagic Software using a superimposition technique to calculate volumetric wear, and surface changes were examined using scanning electron microscopy. Statistical analysis was conducted using one-way ANOVA for quantitative comparison. Results: Shining 3D demonstrated the greatest material wear (0.51 mm³), followed by NextDent (0.27 mm³), while zirconia exhibited the least (0.13 mm³). Conversely, zirconia caused the highest antagonist wear (0.25 mm³), followed by NextDent (0.17 mm³) and Shining 3D (0.12 mm³), although these differences were not statistically significant. Distinct wear patterns were observed for each material. Conclusions: Within the limitations of this in vitro study, NextDent exhibited greater wear resistance than Shining 3D. Both 3D-printing resins produced less antagonist enamel wear than zirconia, underscoring their potential as promising alternatives in pediatric restorative dentistry. Further studies employing diverse materials and standardized protocols are required to validate these findings and enhance clinical translation.