MLMaximilian Ludwig

Maximilian Ludwig

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Maximilian Ludwig has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Predicting global and regional respiratory response in ARDS patients through individualized physics-based computational lung models: A prospective clinical pilot study

    by Armin Sablewski, Maximilian Ludwig, Carolin Eichinger, Matthias Lindner, Inéz Frerichs, Patrick Langguth, Dirk Schädler, Wolfgang A. Wall, Tobias Becher

    Background Lung-protective ventilation is essential in the management of acute respiratory distress syndrome (ARDS), but current approaches are limited by the heterogeneity of lung pathology and a lack of individualized strategies. Patient-specific computational models may overcome these limitations by providing predictive and physiologically interpretable insights into global and regional lung behavior. Methods Ten mechanically ventilated patients with ARDS were evaluated in a monocentric prospective pilot study. A predefined study protocol included ventilatory maneuvers with systematic changes in ventilator mode, tidal volume, positive end-expiratory pressure (PEEP), and driving pressure. For each patient, a personalized, regionally resolved physics-based computational lung model was generated and calibrated to reproduce the individual respiratory system mechanics. Model predictions of tidal volume, airway and transpulmonary pressures, end-expiratory lung volume (EELV), and electrical impedance tomography (EIT)-derived regional ventilation distribution were simulated for different PEEP levels and evaluated against clinically assessed reference values. Model predictions were compared to clinical data using Pearson correlation coefficients (r), root mean square error (RMSE), and Bland–Altman analyses. Results A strong agreement was observed between simulated and clinical data for tidal volumes (r = 0.925, p < 0.001, RMSE = 0.053 l) and driving pressures (r = 0.940, p < 0.001, RMSE = 1.328 mbar) across all PEEP levels. At initial PEEP level, we found a high image correlation (r > 0.8) was found between measured and simulated regional ventilation in five of seven patients where EIT data were available. Conclusions This pilot study demonstrates the capability of the individualized, regionally resolved physics-based computational lung model to reproduce patient-specific respiratory mechanics and key features of regional ventilation patterns in ARDS. The strong agreement between simulated and measured data supports the potential of this approach to estimate the physiological response to ventilator adjustments and lays the groundwork for future studies integrating computational modeling into clinical decision-making. Trial registration: Registered at the German Clinical Trials Register (DRKS00017151, https://drks.de/search/en/trial/DRKS00017151) at 12th April 2019

  • Open Access

    Anatomically informed GREIT reconstruction: improving EIT imaging for lung monitoring

    by Maximilian Ludwig, Carolin M Geitner, Armin Sablewski, Inéz Frerichs, Tobias Becher, Wolfgang A Wall

    Objective: Time-difference electrical impedance tomography (EIT) is gaining widespread use for bedside lung monitoring in intensive care patients suffering from lung-related diseases. It involves collecting voltage measurements from electrodes placed on the patient’s thorax, which are then used to reconstruct impedance images. This study investigates how incorporating anatomical information from CT data into the widely used GREIT reconstruction algorithm affects EIT images and improves their interpretability. Approach: Based on clinically motivated lung state scenarios, we simulated EIT measurements to assess how the GREIT parameters influence the result of EIT image reconstruction, particularly with respect to noise performance and image accuracy. We introduce quality measures that allow us to perform a quantitative assessment of reconstruction quality. We incorporate the anatomical features of a patient from CT data by customizing the background conductivity and the distribution of GREIT training targets. Main results: Our analysis confirmed that unphysiological background conductivity assumptions can lead to misleading EIT images, whereas physiological values, although more accurate, come with higher noise sensitivity. By increasing the number of GREIT training targets inside the lung and adapting the respective weighting radius, we significantly improved the anatomical accuracy of the EIT images. When applied to clinical EIT data from a representative ARDS patient, these adjustments in the reconstruction setup substantially enhanced the interpretability of the resulting EIT images. Significance: Incorporating CT-based anatomical data in the GREIT reconstruction significantly enhances the clinical applicability of EIT in lung monitoring. The improved interpretability of EIT images facilitates better-informed clinical decisions and the individualized adjustment of ventilation strategies for critically ill patients.


  • Patient-specific prediction of regional lung mechanics in patients with ARDS with physics-based models: a validation study

    by Maximilian Rixner, Maximilian Ludwig, Matthias Lindner, Inéz Frerichs, Armin Sablewski, Karl-Robert Wichmann, Max-Carl Wachter, Kei W. Müller, Dirk Schädler, Wolfgang A. Wall, et al.

    This study presents the first systematic validation of physics-based, patient-specific computational lung models for mechanically ventilated patients. By comparing model-predicted regional ventilation with bedside electrical impedance tomography, we demonstrate the ability of our computational approach to predict regional lung mechanics and patient-specific phenomena. Embedded within a computational pipeline fast enough for clinical workflows, this marks a significant step toward truly personalized, model-informed ventilation management in the ICU.


  • Open Access

    Anatomically Informed GREIT Reconstruction: Improving EIT Imaging for Lung Monitoring

    by Maximilian Ludwig, Carolin M. Eichinger, Armin Sablewski, Inéz Frerichs, Tobias Becher, Wolfgang A. Wall

    Objective: Time-difference electrical impedance tomography (EIT) is gaining widespread use for bedside lung monitoring in intensive care patients suffering from lung-related diseases. It involves collecting voltage measurements from electrodes placed on the patient's thorax, which are then used to reconstruct impedance images. This study investigates how incorporating anatomical information from CT data into the widely used GREIT reconstruction algorithm affects EIT images and improves their interpretability. Approach: Based on clinically motivated lung state scenarios, we simulated EIT measurements to assess how the GREIT parameters influence the result of EIT image reconstruction, particularly with respect to noise performance and image accuracy. We introduce quality measures that allow us to perform a quantitative assessment of reconstruction quality. Anatomical features from CT data were included by customizing background conductivity and GREIT training target distribution. Main results: Our analysis confirmed that unphysiological background conductivity assumptions can lead to misleading EIT images, whereas physiological values, although more accurate, come with higher noise sensitivity. By increasing the number of GREIT training targets inside the lung and adapting the respective weighting radius, we significantly improved the anatomical accuracy of the EIT images. When applied to clinical EIT data from a representative ARDS patient, these adjustments in the reconstruction setup substantially enhanced the interpretability of the resulting EIT images. Significance: Integrating CT-based anatomical data in the GREIT reconstruction significantly enhances the clinical applicability of EIT in lung monitoring. The improved interpretability of EIT images facilitates better-informed clinical decisions and the individualized adjustment of ventilation strategies for critically ill patients.