Michael Buchhorn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michael Buchhorn has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Dominik Dworschak
Forschungszentrum Jülich GmbH, Helmholtz Institute for Renewable Energy Erlangen-Nürnberg, Cauerstr. 1, 91058 Erlangen, Germany
3 shared publications - Andreas Hutzler
Helmholtz Institute Erlangen‐Nürnberg for Renewable Energy (IET‐2) Forschungszentrum Jülich GmbH Erlangen Germany
2 shared publications - Karl Johann Jakob Mayrhofer
Department of Chemical and Biological Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstraße 1, Erlangen, Germany, 91058
2 shared publications - Ahmad Tirmidzi
University of Bern
1 shared publication - Andreas Körner
Helmholtz Institute Erlangen‐Nürnberg for Renewable Energy (IET‐2) Forschungszentrum Jülich GmbH Erlangen Germany
1 shared publication - Anna Teressa Sophie Freiberg
Helmholtz-Institute Erlangen-Nürnberg for Renewable Energy (IET-2), Forschungszentrum Jülich GmbH , Cauerstr. 1
1 shared publication
Latest Publications
- Open Access
- 22 October 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 14 (63) , 43862-43872
A scanning flow cell approach for generation of electrocatalyst material libraries via electrodeposition
Automated electrodeposition and activity–stability screening of Au–Pd–Pt nanoparticle libraries for ORR catalysis.
- 22 October 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 14 (63) , 43862-43872
Open AccessA scanning flow cell approach for generation of electrocatalyst material libraries via electrodeposition
Automated electrodeposition and activity–stability screening of Au–Pd–Pt nanoparticle libraries for ORR catalysis.
- Open Access
- 25 May 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Tracing Dissolved Iridium in Proton Exchange Membrane Water Electrolysis Using Operando Hard-X-Ray Fluorescence
Dissolution of iridium in proton exchange membrane water electrolyzer anodes is a critical challenge on the path towards low-cost and durable water electrolysis. While end-of-test analysis of electrolyzers showed that most of the dissolved catalyst redeposits in the membrane and the cathode catalyst layer, this approach offers only limited insight into the dynamics of iridium dissolution, transport, and redeposition mechanisms. By means of 2D-mapping with synchrotron-based operando X-ray fluorescence (XRF) spectroscopy, we detected dissolved iridium in the membrane electrode assembly (MEA) during electrolysis operation and traced the dynamics of its transport under varied operation conditions with reasonable temporal (20 min per map) and spatial (10 µm) resolution. During electrolysis, we observed an accumulation of dissolved iridium in the cathode catalyst layer. With the toggling flow of dry gas at the cathode, we can distinguish between mobile and redeposited iridium. Though thermodynamically favored, no significant deposition within the cathode was observed after ~1 h of electrolysis. The results obtained are another puzzle piece in the understanding of iridium dissolution in electrolyzers towards its possible mitigation.
- 25 May 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessTracing Dissolved Iridium in Proton Exchange Membrane Water Electrolysis Using Operando Hard-X-Ray Fluorescence
Dissolution of iridium in proton exchange membrane water electrolyzer anodes is a critical challenge on the path towards low-cost and durable water electrolysis. While end-of-test analysis of electrolyzers showed that most of the dissolved catalyst redeposits in the membrane and the cathode catalyst layer, this approach offers only limited insight into the dynamics of iridium dissolution, transport, and redeposition mechanisms. By means of 2D-mapping with synchrotron-based operando X-ray fluorescence (XRF) spectroscopy, we detected dissolved iridium in the membrane electrode assembly (MEA) during electrolysis operation and traced the dynamics of its transport under varied operation conditions with reasonable temporal (20 min per map) and spatial (10 µm) resolution. During electrolysis, we observed an accumulation of dissolved iridium in the cathode catalyst layer. With the toggling flow of dry gas at the cathode, we can distinguish between mobile and redeposited iridium. Though thermodynamically favored, no significant deposition within the cathode was observed after ~1 h of electrolysis. The results obtained are another puzzle piece in the understanding of iridium dissolution in electrolyzers towards its possible mitigation.
- Open Access
- 4 September 2025
- Published by Royal Society of Chemistry (RSC) in Digital Discovery
- Vol. 4 (10) , 2864-2875
An open-source peristaltic pump with multiple independent channels for laboratory automation
In recent years laboratory automation, high throughput characterization and self-driving laboratories have emerged as promising tools to accelerate the process of researching and developing novel materials. Many of these automated setups rely on precise and reliable liquid handling to perform their large-scale studies. Peristaltic pumps, with their simple and robust design, a low price point and only the tube itself being in contact with the fluid, are well suited to power these increasingly more complex liquid handling tasks. While existing open-source designs of peristaltic pumps already feature multiple channels to accommodate the need for more fluid lines, these channels are all powered by a single motor and can therefore not run independently of each other, reducing their usability and versatility. To overcome this limitation, we developed an open-source peristaltic pump with four fully independent pumping channels, a quick-swap cassette system and an automation friendly SiLA 2 interface. The design was created with lab automation and self-driving laboratories in mind and allows for flow rates from 0.3 μL min−1 to 8 mL min−1 with a repeatability of 0.2%. Another focus of the design was accessibility, with the pump built from 3D-printed parts and commonly available standardized and off-the-shelf hardware components, resulting in an affordable price point of around 280 USD.
- 4 September 2025
- Published by Royal Society of Chemistry (RSC) in Digital Discovery
- Vol. 4 (10) , 2864-2875
Open AccessAn open-source peristaltic pump with multiple independent channels for laboratory automation
In recent years laboratory automation, high throughput characterization and self-driving laboratories have emerged as promising tools to accelerate the process of researching and developing novel materials. Many of these automated setups rely on precise and reliable liquid handling to perform their large-scale studies. Peristaltic pumps, with their simple and robust design, a low price point and only the tube itself being in contact with the fluid, are well suited to power these increasingly more complex liquid handling tasks. While existing open-source designs of peristaltic pumps already feature multiple channels to accommodate the need for more fluid lines, these channels are all powered by a single motor and can therefore not run independently of each other, reducing their usability and versatility. To overcome this limitation, we developed an open-source peristaltic pump with four fully independent pumping channels, a quick-swap cassette system and an automation friendly SiLA 2 interface. The design was created with lab automation and self-driving laboratories in mind and allows for flow rates from 0.3 μL min−1 to 8 mL min−1 with a repeatability of 0.2%. Another focus of the design was accessibility, with the pump built from 3D-printed parts and commonly available standardized and off-the-shelf hardware components, resulting in an affordable price point of around 280 USD.