TLTiago Guerzet Sardenberg Lima

Tiago Guerzet Sardenberg Lima

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tiago Guerzet Sardenberg Lima has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Identifying cytokine-release signatures of flow-driven endothelial remodelling in an intracranial aneurysm cell culture model

    by Chloe M. de Nys, Tiago Guerzet Sardenberg Lima, Haveena Anbananthan, Timothy Mitchell, Salma Mansi, Alyssa Binder, Zhiyong Li, James I. Novak, Petra Mela, Steven G. Wise, et al.

    Intracranial aneurysm (IA) rupture is catastrophic, yet current models of rupture-risk inadequately capture underlying IA remodelling mechanisms. Endothelial-haemodynamic interactions are central to these processes, but in vitro flow platforms often lack vessel-relevant geometry or long-term perfusion. Here, temporal and spatial endothelial responses to haemodynamic stress were investigated across idealised and patient-specific vascular models. Polydimethylsiloxane models were endothelialised with human aortic endothelial cells then perfused at up to 1.6 Pa wall shear stress for five days. IA models were exposed to steady or cardiovascular flow waveforms, with endothelial phenotype assessed by immunofluorescence and cytokine profiling. Flow initiation induced a transient inflammatory response, with elevated MCP-1 and TNF-α at day two, followed by a resolution of cytokine levels by day five, including a ∼7.5-fold reduction in MCP-1, despite increased haemodynamic loading. Endothelial cells retained a cobblestone-like morphology with eNOS undetected, resembling a partially activated phenotype. Compared with steady flow, cardiovascular flow reduced TGF-β1 and IL-8 secretion and decreased FGF-b consumption (∼2.5 fold), suggesting enhanced phenotypic stability. This study presents the first in vitro IA model incorporating a cardiovascular flow waveform and identifies cytokine signatures with potential utility as biomarkers of IA remodelling, highlighting the importance of long-term perfusion for modelling chronic vascular disease. Table of Contents Figure: An in vitro model of an intracranial aneurysm was developed to investigate how fluid flow dynamics impact endothelial remodelling and inflammation. Pulsatile cardiac flow promoted stabilisation of inflammatory signalling, which was sustained under a steady flow regime. Cytokine signatures emerged with potential utility as biomarkers of IA remodelling, highlighting the importance of long-term perfusion for modelling chronic vascular disease. The schematic of the cytokine release dynamics used in the graphical abstract below was generated with the assistance of AI-based tools including ChatGPT (v5.5) and M365 Copilot to align with key results from this manuscript.

  • Open Access

    Fidelity of wall tap pressure measurements in steady and pulsatile flow

    by Tiago Guerzet Sardenberg Lima, Navid Freidoonimehr, Jessica Benitez Mendieta, Haveena Anbananthan, Mingyang Yuan, Han Yu, Yasindu Wickrama Surendra, Zhiyong Li

    Accurate wall pressure measurements quantify pressure gradients in internal flows, yet a flush wall tap is not passive: tap geometry can bias static pressure, and the tap, pressure tubing, and sensor pathway can attenuate pulsatile fluctuations. We quantify wall pressure measurement fidelity over Reynolds numbers up to 704 by separating steady tap effects, dynamic transmission, and sensitivity to as-built geometry in experiments and computational fluid dynamics (CFD). Steady tests evaluated tap diameter bias (0.4, 0.8, and 1.0 mm) and compared CFD on computer-aided design and micro-computed tomography reconstructed lumens. A symmetric phantom with mirrored taps was tested at 1 Hz to quantify attenuation for 0.5 and 1.0 mm taps and two tubing lengths (560 and 2240 mm). The workflow was applied to a patient-specific intracranial aneurysm (IA) phantom with ten taps, fabricated by three-dimensional printing. Steady cases and a sinusoidal case were compared with matched rigid-wall CFD driven by the measured inflow waveform. Tap diameter weakly affected steady differential pressure, but 0.5 mm taps attenuated pulsatile amplitude, while tubing length changed amplitude by <1% at 1 Hz. In the IA phantom, the main discrepancies were in pressure magnitude rather than spatial pattern: CFD captured normalized spatial pressure distributions but underpredicted gauge pressure by 22%–28% in steady flow, pulsatile amplitude by 42%, and peak differential pressure by 15%. These results show that agreement in waveform shape or spatial trends can coexist with large magnitude error unless pressure transmission, as-built geometry, and inlet definition are verified and uncertainties are considered.

  • Open Access

    Haemodynamic characteristics of thin-walled regions in intracranial aneurysms: intraoperative imaging and CFD analysis

    by Haveena Anbananthan, Phani Kumari Paritala, Jessica Benitez Mendieta, Han Yu, Tiago Guerzet Sardenberg Lima, Zoe Dettrick, Ee Shern Liang, Alan Coulthard, Zhi-Yong Li, Craig Winter

    Background: Identifying haemodynamic factors associated with thin-walled regions (TWRs) of intracranial aneurysms is critical for improving pre-surgical rupture risk assessment. Intraoperatively, these regions are visually distinguished by a red, translucent appearance and are considered highly rupture prone. However, current imaging modalities lack the resolution to detect such vulnerable areas preoperatively. This study aimed to determine whether thin-walled regions exhibit distinct local haemodynamic profiles compared to adjacent normal-appearing wall regions. Methods: Sixteen patient-specific models of unruptured middle cerebral artery aneurysms were reconstructed from digital subtraction angiography images. Intraoperative TWRs were identified using a colour segmentation method based on Delta E metrics. Computational fluid dynamics (CFD) simulations were used to compute six haemodynamic parameters: wall shear stress (WSS), time-averaged WSS (TaWSS), oscillatory shear index (OSI), relative residence time (RRT), WSS divergence (WSSD), and pressure. Haemodynamic data were extracted from spatially localised surface patches within confirmed thin and normal regions. Linear mixed-effects models were applied to compare parameters while accounting for patient-level and intra-patient variability, using normalised values to improve model fit. Results: Thin regions exhibited significantly higher WSS, TaWSS, WSSD, and pressure, and reduced RRT. WSS and TaWSS were approximately 3.3% and 2.8% higher in TWRs, respectively. WSSD was 5.4% higher and RRT was 0.3% lower, suggesting faster, more divergent flow in thin regions. Pressure was modestly but significantly elevated at + 1.3%. No significant difference was observed in OSI between regions. Conclusions: Thin-walled regions in intracranial aneurysms demonstrate a distinctive haemodynamic profile characterised by stronger, sustained shear forces, greater shear divergence, and reduced residence time, suggesting a dynamic mechanical environment that promotes focal wall thinning. Our findings suggest that persistent shear-driven stress, rather than oscillatory flow, is a key haemodynamic feature of thin-walled regions and may contribute to localised aneurysm wall vulnerability.