JHJianfeng He

Jianfeng He

*This is an algorithmically generated author record based on publicly available information.

Jianfeng He has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Bin Yang

    State Grid Wuhan Power Supply Company, Wuhan 430070, China

    1 shared publication
  • Bo Li

    Hubei Engineering Research Center for Safety Monitoring of New Energy and Power Grid Equipment, Hubei University of Technology, Wuhan 430068, China

    1 shared publication
  • Hang Wang

    Hubei Engineering Research Center for Safety Monitoring of New Energy and Power Grid Equipment, Hubei University of Technology, Wuhan 430068, China

    1 shared publication
  • Jing Tu

    Electrical Cable Operation and Maintenance Branch of Wuhan Power Supply Company, Hubei Power Supply Company, State Grid, Wuhan 430024, China

    1 shared publication
  • Minghong Jiang

    Hubei Engineering Research Center for Safety Monitoring of New Energy and Power Grid Equipment, Hubei University of Technology, Wuhan 430068, China

    1 shared publication
  • Ruoxin Song

    Hubei Jiji Electric Power Group Company Ltd., Wuhan Economic and Technological Development District, Wuhan 430000, China

    1 shared publication

Latest Publications

  • Open Access

    Two-Sheath Loop Short Circuit Defects Detection in High-Voltage Cable Systems Using Sheath Current Phasors

    by Weihua Yuan, Jing Tu, Yongheng Ai, Zhanran Xia, Ruoxin Song, Jianfeng He, Xinyun Gao, Minghong Jiang, Bin Yang, Bo Li, et al.

    The joint is the weak point of HV (high voltage) cable insulation systems; creep discharge between insulation layers of the cable joint, due to moisture intrusion, is one of the main defects leading to single-phase grounding. Carbonization on the insulation interface after creep discharge would lead to a short-circuit defect in the sheath loops and result in abnormal sheath current. In this study, a novel diagnostic criterion using the phasor difference of sheath currents at both ends of the same circuit is proposed. The coupling effect between the sheath and the conductor under defect conditions is considered, and the original lumped parameter model of the cable circuit is optimized. The cable parameters are further corrected using a genetic algorithm. The diagnostic criterion comprehensively accounts for the adverse effects of unequal cable segment lengths, load current fluctuations, grounding impedance, and phase voltage variations. When the phase angle fluctuation of the phasor difference is within 10° and the defect impedance is below 100 Ω, the defective joint can be accurately diagnosed by this method. The conclusion has been validated through PSCAD simulations, with a diagnostic accuracy above 97%. Even under 20 dB noise interference, the error increase remains within 2%.