BLBo Li

Bo Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bo Li has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Sheath-to-Ground Fault Impedance Calculation and Localization Method in Cross-Bonded High-Voltage Cable Systems

    by Hang Wang, Bo Li, Liqiang Wang, Jing Tu, Shuai Yang, Jun Chen

    Abnormal circulating current induced by sheath grounding faults in cross-bonded high-voltage cables is a major cause of single-phase grounding faults. For the early detection and localization of sheath grounding faults, this paper constructs an equivalent circuit model for three-phase nine-section cross-bonded cables. Circuit model parameters are estimated via online monitoring data. The relational equation between sheath electrical quantities, fault impedance, and distance is derived for typical sheath grounding faults. Using the Adam algorithm, the solution of fault impedance and location is converted into the minimization of an optimization objective function. Simulation results show that under the influences of phase current imbalance, measurement error, and fault impedance fluctuation, the Adam algorithm exhibits superior optimization accuracy and computational efficiency in comparison with the ED and GA algorithms. Experimental results show that for low-resistance sheath grounding, the proposed method has a fault impedance calculation error ≤ 0.59% and a fault positioning error ≤ 1.89%. For metallic sheath grounding with zero resistance, the positioning error is ≤1.37%. Field test results demonstrate that the proposed method performs similarly to the time-domain reflectometry method, with a positioning deviation ≤ 0.15 m, and can meet online monitoring requirements.

  • Open Access

    Two-Sheath Loop Short Circuit Defects Detection in High-Voltage Cable Systems Using Sheath Current Phasors

    by Weihua Yuan, Jing Tu, Yongheng Ai, Zhanran Xia, Ruoxin Song, Jianfeng He, Xinyun Gao, Minghong Jiang, Bin Yang, Bo Li, et al.

    The joint is the weak point of HV (high voltage) cable insulation systems; creep discharge between insulation layers of the cable joint, due to moisture intrusion, is one of the main defects leading to single-phase grounding. Carbonization on the insulation interface after creep discharge would lead to a short-circuit defect in the sheath loops and result in abnormal sheath current. In this study, a novel diagnostic criterion using the phasor difference of sheath currents at both ends of the same circuit is proposed. The coupling effect between the sheath and the conductor under defect conditions is considered, and the original lumped parameter model of the cable circuit is optimized. The cable parameters are further corrected using a genetic algorithm. The diagnostic criterion comprehensively accounts for the adverse effects of unequal cable segment lengths, load current fluctuations, grounding impedance, and phase voltage variations. When the phase angle fluctuation of the phasor difference is within 10° and the defect impedance is below 100 Ω, the defective joint can be accurately diagnosed by this method. The conclusion has been validated through PSCAD simulations, with a diagnostic accuracy above 97%. Even under 20 dB noise interference, the error increase remains within 2%.