JDJustyna Darmochwał-Podoba

Justyna Darmochwał-Podoba

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Justyna Darmochwał-Podoba has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis of CO2 emissions in the context of the application of selected heat pumps in fossil-fuel-based power systems

    by Justyna Darmochwał-Podoba, Sławomir Rabczak

    In the context of the global increase in energy demand and the progressive depletion of fossil fuel resources, there is a noticeable intensification of efforts aimed at reducing the use of non-renewable raw materials in favor of developing and implementing technologies based on renewable energy...

  • Open Access

    Comparative Analysis of Two Methodologies for Calculating Energy Performance and Energy Demand: a Case Study of the Municipal Office and Village Administration Building

    by Justyna Darmochwał-Podoba, Sławomir Rabczak

    In response to increasingly stringent European Union directives and national regulations on the energy performance of buildings, reliable and interpretable energy assessment methods are essential, particularly for public utility buildings due to their large floor areas and significant contribution to national energy demand. This study compares regulatory calculation results obtained for an administrative public utility building using two frameworks: the energy performance certificate (EPC) procedure and the energy audit methodology. The objective is to quantify methodological discrepancies and to indicate which model assumptions most strongly affect ventilation–related losses and the resulting energy indicators. For the investigated building, the ventilation heat loss coefficient determined within the audit methodology was 37% higher than that obtained under the EPC procedure, which translated into an over 31% higher useful energy demand for heating and ventilation. The audit–based EU and EK indicators were higher than those calculated within the EPC framework, while the EP indicator remained at a comparable level, indicating that differences in methodological assumptions can substantially alter the distribution of useful and final energy components without necessarily producing a proportional change in primary energy. The reported differences should be interpreted as consequences of distinct regulatory algorithms and input treatment (including ventilation and infiltration air flow rates and system efficiency assumptions) rather than as evidence of divergence from actual operational energy use, as measurement–based validation was not performed. The findings support a more cautions interpretation of EPC and audit outputs and underline the need for broader case samples and operational data to generalise results.

  • Open Access

    Energy-Autonomous Cooling of Open Spaces—The Impact of Thermal Comfort Temperature on the Cooperation of the Cooling System with the PV Installation

    by Ewelina Barnat, Robert Sekret, Sławomir Rabczak, Justyna Darmochwał-Podoba

    Climate change and rising temperatures in cities due to the urban heat island (UHI) effect are causing increased heat stress and driving the development of efficient, sustainable outdoor cooling systems. The aim of this article was to analyze the integration of adiabatic air cooling systems with photovoltaic (PV) installations in the context of improving thermal comfort and energy autonomy. The study was conducted on the example of a bus station in Rzeszow (Poland), considering two system variants: indirect evaporative cooling and direct evaporative cooling. To assess the impact of comfort parameters on the number of hours of system operation, energy consumption, and operating costs, four upper thermal comfort limits were considered: 22 °C, 22.9 °C, 24 °C, and 25 °C. The results indicate that increasing the upper limit of thermal comfort reduces the operating time of the system and significantly reduces the demand for cooling—for example, increasing the thermal comfort range from 22.9 °C to 24 °C reduces useful energy by 41%. Assuming a thermal comfort range of 25 °C, the direct evaporative cooling system achieves full energy autonomy and is fully powered by photovoltaics. Life cycle analysis (LCA) and life cycle cost (LCC) confirmed the environmental and economic benefits of using higher thermal comfort values. The study highlights the potential of adiabatic cooling systems, in conjunction with a local photovoltaic installation, as an adaptive solution that improves thermal comfort in urban spaces with minimal energy consumption from the grid.

  • Open Access

    Energy-Autonomous Cooling of Open Spaces—The Impact of Thermal Comfort Temperature on the Cooperation of the Cooling System with the PV Installation

    by Ewelina Barnat, Robert Sekret, Slawomir Rabczak, Justyna Darmochwał-Podoba

    Climate change and rising temperatures in cities as a result of the Urban Heat Island (UHI) are increasing heat stress and forcing the development of efficient, sustainable outdoor cooling systems. The aim of this article was to analyse the integration of adiabatic air cooling systems with photovoltaic (PV) installations in the context of improving thermal comfort and energy autonomy. The study was carried out on the example of a bus station in Rzeszów (Poland), considering two variants of systems: indirect evaporative cooling (PKW/PV-CP-KW) and direct evaporative cooling (BKW/PV-CP-KW). Four levels of the upper limit of thermal comfort (TEmax = 22°C, 22.9°C, 24°C, 25°C) were considered to assess the impact of comfort parameters on the number of hours of system operation, energy consumption and operating costs. The results indicate that raising the TEmax reduces system uptime and significantly reduces the need for cooling – for example, increasing the TEmax from 22.9°C to 24°C reduces usable energy by 41%. At TEmax = 25°C, the BKW system achieves full energy autonomy, it is fully powered by PV. A Life Cycle Analysis (LCA) and Operating Cost of Ownership (LCC) confirmed the environmental and economic benefits of using higher TEmax values. The study highlights the potential of adiabatic cooling systems, in cooperation with a local PV installation, as an adaptive solution, improving thermal comfort in urban space with minimal grid energy consumption.