Xiaolong Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaolong Zhang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Guoming Ma
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
1 shared publication - Jialin Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources and Beijing Key Laboratory of High Voltage and EMC, North China Electric Power University, Beijing, China
1 shared publication - Jing Hu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
1 shared publication - Sihan Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
1 shared publication - Weiqi Qin
Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
1 shared publication
Latest Publications
- 7 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Multipoint Ultrasonic Detection and Localization of Transformer Partial Discharge Using FDM- φ OTDR
Partial discharge (PD) detection is crucial for maintaining transformer safety. Multi-point ultrasonic detection of transformer PD leads to accurate localization and early warning of insulation defects. To increase the number of ultrasonic measurement points, this paper proposed a novel method for multi-point detection using frequency division multiplexing (FDM) phase-sensitive optical time-domain reflectometry (φOTDR) system. The proposed method expanded the traditional response frequency band of φOTDR by four times, enabling the simultaneous detection of PD ultrasonic signals at 10 points with a frequency band of 0~200 kHz. Experiment result confirmed the accurate localization of the transformer PD model. The proposed FDM-φOTDR system enables comprehensive PD monitoring without the need for manual relocating of measurement points, making it suitable for in-service detection and on-line monitoring of transformer PD.
- 7 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Multipoint Ultrasonic Detection and Localization of Transformer Partial Discharge Using FDM- φ OTDR
Partial discharge (PD) detection is crucial for maintaining transformer safety. Multi-point ultrasonic detection of transformer PD leads to accurate localization and early warning of insulation defects. To increase the number of ultrasonic measurement points, this paper proposed a novel method for multi-point detection using frequency division multiplexing (FDM) phase-sensitive optical time-domain reflectometry (φOTDR) system. The proposed method expanded the traditional response frequency band of φOTDR by four times, enabling the simultaneous detection of PD ultrasonic signals at 10 points with a frequency band of 0~200 kHz. Experiment result confirmed the accurate localization of the transformer PD model. The proposed FDM-φOTDR system enables comprehensive PD monitoring without the need for manual relocating of measurement points, making it suitable for in-service detection and on-line monitoring of transformer PD.