Jialin Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jialin Wang has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Guoming Ma
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
3 shared publications - Sihan Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
3 shared publications - Weiqi Qin
Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
2 shared publications - Hao Liu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
1 shared publication - Houxian Du
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources and Beijing Key Laboratory of High Voltage and EMC, North China Electric Power University, Beijing, China
1 shared publication Jianbo Zhang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources and Beijing Key Laboratory of High Voltage and EMC, North China Electric Power University, Beijing, China
1 shared publication
Latest Publications
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (7) , 10350-10357
Design and Laboratory Evaluation of a Distributed Vibration Detection Method for Power Transformers Using COTDR and Mandrel-Type Fiber Optic Sensors
The vibration signal analysis method can detect transformer vibration signals and diagnose mechanical faults non-invasively. A high-sensitivity mandrel-type fiber optic sensor for distributed detection of vibration signals on transformer surfaces was presented in this paper, based on coherent optical time domain reflectometry (COTDR). Firstly, the influence of the mandrel structure, dimensions, and materials on sensitivity was investigated through finite element simulation and experiments. The sensitivity enhancement method for the mandrel sensor was derived, which led to the determination of the most sensitive sensor manufacturing scheme. Then, through experimental verification, sensor achieved a sensitivity of 20.50 rad/g, with a detectable vibration frequency range of 100 Hz to 1 kHz and a minimum detectable acceleration of 0.01 g, which is the possible minimum value of the transformer vibration signal. Experimental verification confirmed that the sensor array enables distributed detection over 5 km of sensing optical fiber, supporting simultaneous monitoring at 100 measurement points. Additionally, a differential-unwrapping-integration (DUI) algorithm was introduced to address the issue of high-frequency, large-amplitude vibration signal wrapping in the digital domain.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (7) , 10350-10357
Design and Laboratory Evaluation of a Distributed Vibration Detection Method for Power Transformers Using COTDR and Mandrel-Type Fiber Optic Sensors
The vibration signal analysis method can detect transformer vibration signals and diagnose mechanical faults non-invasively. A high-sensitivity mandrel-type fiber optic sensor for distributed detection of vibration signals on transformer surfaces was presented in this paper, based on coherent optical time domain reflectometry (COTDR). Firstly, the influence of the mandrel structure, dimensions, and materials on sensitivity was investigated through finite element simulation and experiments. The sensitivity enhancement method for the mandrel sensor was derived, which led to the determination of the most sensitive sensor manufacturing scheme. Then, through experimental verification, sensor achieved a sensitivity of 20.50 rad/g, with a detectable vibration frequency range of 100 Hz to 1 kHz and a minimum detectable acceleration of 0.01 g, which is the possible minimum value of the transformer vibration signal. Experimental verification confirmed that the sensor array enables distributed detection over 5 km of sensing optical fiber, supporting simultaneous monitoring at 100 measurement points. Additionally, a differential-unwrapping-integration (DUI) algorithm was introduced to address the issue of high-frequency, large-amplitude vibration signal wrapping in the digital domain.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 9538710
High-Sensitivity Partial Discharge Detection in Cable Joints Over Long Distances Based on Chirped Phase-Sensitive Optical Time-Domain Reflectometry
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 9538710
High-Sensitivity Partial Discharge Detection in Cable Joints Over Long Distances Based on Chirped Phase-Sensitive Optical Time-Domain Reflectometry
- 7 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Multipoint Ultrasonic Detection and Localization of Transformer Partial Discharge Using FDM- φ OTDR
Partial discharge (PD) detection is crucial for maintaining transformer safety. Multi-point ultrasonic detection of transformer PD leads to accurate localization and early warning of insulation defects. To increase the number of ultrasonic measurement points, this paper proposed a novel method for multi-point detection using frequency division multiplexing (FDM) phase-sensitive optical time-domain reflectometry (φOTDR) system. The proposed method expanded the traditional response frequency band of φOTDR by four times, enabling the simultaneous detection of PD ultrasonic signals at 10 points with a frequency band of 0~200 kHz. Experiment result confirmed the accurate localization of the transformer PD model. The proposed FDM-φOTDR system enables comprehensive PD monitoring without the need for manual relocating of measurement points, making it suitable for in-service detection and on-line monitoring of transformer PD.
- 7 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Multipoint Ultrasonic Detection and Localization of Transformer Partial Discharge Using FDM- φ OTDR
Partial discharge (PD) detection is crucial for maintaining transformer safety. Multi-point ultrasonic detection of transformer PD leads to accurate localization and early warning of insulation defects. To increase the number of ultrasonic measurement points, this paper proposed a novel method for multi-point detection using frequency division multiplexing (FDM) phase-sensitive optical time-domain reflectometry (φOTDR) system. The proposed method expanded the traditional response frequency band of φOTDR by four times, enabling the simultaneous detection of PD ultrasonic signals at 10 points with a frequency band of 0~200 kHz. Experiment result confirmed the accurate localization of the transformer PD model. The proposed FDM-φOTDR system enables comprehensive PD monitoring without the need for manual relocating of measurement points, making it suitable for in-service detection and on-line monitoring of transformer PD.