Ido Luiz de Azevedo Feiten
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ido Luiz de Azevedo Feiten has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Larissa Maria Cavalcante
Universidade Federal Fluminense
5 shared publications - Luis Felipe Jochinms Schneider
Universidade Federal Fluminense
4 shared publications - André Luis Faria-E-Silva
Department of Dentistry, Dental School, Laval University, Québec QC, Canada
2 shared publications - Eloah Nunes de Almeida
Laboratory for Applied Biotechnology (LABA UFF), School of Dentistry Federal Fluminense University Niterói Brazil
2 shared publications Ana Carolina Do Rosário Costa Lima
Laboratory of Applied Biotechnology, School of Dentistry, Federal Fluminense University, Niterói, RJ, Brazil
1 shared publication- Ana Carolina Santarem
DFL Indústria e Comércio SA
1 shared publication
Latest Publications
- Open Access
- 10 August 2026
- Published by Wiley in European Journal of Oral Sciences
- p. e70125
Optimizing diphenyl(2,4,6‐trimethylbenzoyl)phosphine oxide concentration and post‐curing time to balance mechanical properties and color stability in a three‐dimensional‐printed restorative resin
Three‐dimensional (3D) printing is widely used in dental restorations; however, optimization of photoinitiator concentration and post‐curing protocols remains critical to achieve a balance between mechanical and esthetic performance. This study evaluated the combined effect of diphenyl(2,4,6‐trimethylbenzoyl)phosphine oxide (TPO) concentration and post‐curing time on mechanical properties and color stability of a 3D‐printed restorative resin. A commercial photoinitiator‐free resin (BioPrint Prov, Horus 3D) was supplemented with TPO at 0.5, 1.0, and 1.5 wt% and fabricated using a digital light processing printer. Specimens were post‐cured for 30, 45, or 60 min under UV light, while non‐post‐cured (NoPC) samples served as controls. Flexural strength and elastic modulus were evaluated using a three‐point bending test. Color stability and translucency were assessed using spectrophotometry (CIELab/Δ E 00 ) under storage conditions, including dry storage, water immersion, and coffee aging. Data were analyzed using two‐way anova and Tukey's test. The 1.0% TPO and 30 min post‐curing combination provided best performance, with highest flexural strength and lowest color change after staining. Higher TPO concentration and prolonged post‐curing increased color alteration and yellowness. NoPC specimens showed inferior mechanical properties and greater discoloration. Translucency remained more stable in post‐curing groups. These findings indicate optimized photoinitiator concentration and controlled post‐curing time improve mechanical and esthetic outcomes in 3D‐printed restorative resins.
- 10 August 2026
- Published by Wiley in European Journal of Oral Sciences
- p. e70125
Open AccessOptimizing diphenyl(2,4,6‐trimethylbenzoyl)phosphine oxide concentration and post‐curing time to balance mechanical properties and color stability in a three‐dimensional‐printed restorative resin
Three‐dimensional (3D) printing is widely used in dental restorations; however, optimization of photoinitiator concentration and post‐curing protocols remains critical to achieve a balance between mechanical and esthetic performance. This study evaluated the combined effect of diphenyl(2,4,6‐trimethylbenzoyl)phosphine oxide (TPO) concentration and post‐curing time on mechanical properties and color stability of a 3D‐printed restorative resin. A commercial photoinitiator‐free resin (BioPrint Prov, Horus 3D) was supplemented with TPO at 0.5, 1.0, and 1.5 wt% and fabricated using a digital light processing printer. Specimens were post‐cured for 30, 45, or 60 min under UV light, while non‐post‐cured (NoPC) samples served as controls. Flexural strength and elastic modulus were evaluated using a three‐point bending test. Color stability and translucency were assessed using spectrophotometry (CIELab/Δ E 00 ) under storage conditions, including dry storage, water immersion, and coffee aging. Data were analyzed using two‐way anova and Tukey's test. The 1.0% TPO and 30 min post‐curing combination provided best performance, with highest flexural strength and lowest color change after staining. Higher TPO concentration and prolonged post‐curing increased color alteration and yellowness. NoPC specimens showed inferior mechanical properties and greater discoloration. Translucency remained more stable in post‐curing groups. These findings indicate optimized photoinitiator concentration and controlled post‐curing time improve mechanical and esthetic outcomes in 3D‐printed restorative resins.
- Open Access
- 14 May 2026
- Published by Wiley in European Journal of Oral Sciences
- p. e70106
The influence of post‐curing protocols on the optical properties of provisional and long‐term 3D‐printable resin composites
This study determined the influence of post‐curing protocols on the color stability of provisional and long‐term 3D‐printable resin composites. Disc‐shaped specimens were fabricated from a provisional (Prov) and long‐term (Crown) 3D‐printable resin composites using a digital light processing printer. Post‐curing protocols included exposure to 405 nm‐based light sources (Anycubic for 30 or 60 min in the standard mode or Procure 1) and one 385 nm‐based light source (Procure 2 with distinct protocols). Color parameters ( L *, a *, b *) were measured at baseline, after 14 and 21 d of dry storage, and after 7 d of water immersion. Post‐curing protocol, material, and storage condition significantly influenced color stability. High‐irradiance protocols resulted in the highest color change values, exceeding the clinical acceptability threshold (Δ E 00 > 1.8). Water immersion induced a significant whitening effect and increased total color change in all groups. The long‐term resin demonstrated superior color stability compared to the provisional one across all post‐curing protocols. The choice of post‐curing protocol is critical for aesthetic performance, as high‐irradiance parameters, while potentially beneficial for mechanical properties, can compromise chromatic stability, particularly in materials with low filler content.
- 14 May 2026
- Published by Wiley in European Journal of Oral Sciences
- p. e70106
Open AccessThe influence of post‐curing protocols on the optical properties of provisional and long‐term 3D‐printable resin composites
This study determined the influence of post‐curing protocols on the color stability of provisional and long‐term 3D‐printable resin composites. Disc‐shaped specimens were fabricated from a provisional (Prov) and long‐term (Crown) 3D‐printable resin composites using a digital light processing printer. Post‐curing protocols included exposure to 405 nm‐based light sources (Anycubic for 30 or 60 min in the standard mode or Procure 1) and one 385 nm‐based light source (Procure 2 with distinct protocols). Color parameters ( L *, a *, b *) were measured at baseline, after 14 and 21 d of dry storage, and after 7 d of water immersion. Post‐curing protocol, material, and storage condition significantly influenced color stability. High‐irradiance protocols resulted in the highest color change values, exceeding the clinical acceptability threshold (Δ E 00 > 1.8). Water immersion induced a significant whitening effect and increased total color change in all groups. The long‐term resin demonstrated superior color stability compared to the provisional one across all post‐curing protocols. The choice of post‐curing protocol is critical for aesthetic performance, as high‐irradiance parameters, while potentially beneficial for mechanical properties, can compromise chromatic stability, particularly in materials with low filler content.
- Open Access
- 7 May 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 38 (8) , 1598-1609
Reliability of Three Image‐Based Instrumental Color‐Measurement Methods
Objectives: To compare the precision of three clinically applicable, image‐based color assessment methods—smartphone imaging, a clinical colorimeter (Optishade), and a digital scanning device (Borea Cobra)—against a benchtop spectrophotometer for measuring CIELAB coordinates and CIEDE2000 (Δ E 00 ) color differences of composite resin shades. Materials and Methods: Three specimens from eight composite shades were measured using a benchtop spectrophotometer (reference) and the three test devices. Agreement for L*, a*, and b* was evaluated using linear regression and Bland–Altman analyses. Δ E 00 values relative to the reference and intershade Δ E 00 across shade pairs were analyzed using two‐way ANOVA and regression. Results: Optishade showed the closest agreement with the reference—with slopes near unity, high R 2 values—and the smallest biases and limits of agreement. Borea Cobra demonstrated good overall performance and strong agreement for a* and b*, though with greater data dispersion and device‐specific distortions in intershade differences. Smartphone measurements displayed systematic positive bias, lower slopes for chromatic axes, and wider limits of agreement, indicating reduced precision and compression of color differences. Conclusions: Optishade provided the most reliable quantitative measurements; Borea Cobra offered acceptable performance with specific limitations. Smartphone‐based imaging preserved shade ordering but was unsuitable for precise color quantification.
- 7 May 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 38 (8) , 1598-1609
Open AccessReliability of Three Image‐Based Instrumental Color‐Measurement Methods
Objectives: To compare the precision of three clinically applicable, image‐based color assessment methods—smartphone imaging, a clinical colorimeter (Optishade), and a digital scanning device (Borea Cobra)—against a benchtop spectrophotometer for measuring CIELAB coordinates and CIEDE2000 (Δ E 00 ) color differences of composite resin shades. Materials and Methods: Three specimens from eight composite shades were measured using a benchtop spectrophotometer (reference) and the three test devices. Agreement for L*, a*, and b* was evaluated using linear regression and Bland–Altman analyses. Δ E 00 values relative to the reference and intershade Δ E 00 across shade pairs were analyzed using two‐way ANOVA and regression. Results: Optishade showed the closest agreement with the reference—with slopes near unity, high R 2 values—and the smallest biases and limits of agreement. Borea Cobra demonstrated good overall performance and strong agreement for a* and b*, though with greater data dispersion and device‐specific distortions in intershade differences. Smartphone measurements displayed systematic positive bias, lower slopes for chromatic axes, and wider limits of agreement, indicating reduced precision and compression of color differences. Conclusions: Optishade provided the most reliable quantitative measurements; Borea Cobra offered acceptable performance with specific limitations. Smartphone‐based imaging preserved shade ordering but was unsuitable for precise color quantification.
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 40
In vitro analysis of dimensional stability of fast-setting irreversible hydrocolloids by digital scanning
This study aimed to evaluate the in vitro dimensional stability of Moldeer Fast compared with two commercially available extended-pour, fast-setting irreversible hydrocolloids using direct digital scanning of dental impressions. This experimental in vitro study was conducted using standardized impression techniques on a typodont. Impressions were obtained in random order by a single calibrated operator. Three irreversible hydrocolloids were evaluated: ColorChange (Cavex Holland BV), Hydrogum 5 (Zhermack Spa), and Moldeer Fast (DFL). Ten impressions were obtained per group according to the manufacturers’ instructions and scanned using an intraoral scanner at predetermined intervals (0 h, 24 h, 48 h, 72 h, 96 h, and 120 h). Impressions were stored under controlled temperature and humidity conditions. Four linear measurements were performed on color-masked images in a blind manner to assess dimensional changes over time: a) intercanine distance, b) intermolar distance, c) right canine-to-molar distance, and d) left canine-to-molar distance. Data were analyzed using repeated-measures ANOVA (α = 0.05). All materials exhibited minor dimensional changes, consisting predominantly of slight contraction. However, no statistically significant differences were observed over time (p > 0.05). Moldeer Fast therefore exhibited dimensional stability comparable to that of ColorChange and Hydrogum 5. All materials maintained clinically acceptable dimensional stability for up to five days, supporting their suitability for delayed digital scanning of irreversible hydrocolloid impressions.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 40
Open AccessIn vitro analysis of dimensional stability of fast-setting irreversible hydrocolloids by digital scanning
This study aimed to evaluate the in vitro dimensional stability of Moldeer Fast compared with two commercially available extended-pour, fast-setting irreversible hydrocolloids using direct digital scanning of dental impressions. This experimental in vitro study was conducted using standardized impression techniques on a typodont. Impressions were obtained in random order by a single calibrated operator. Three irreversible hydrocolloids were evaluated: ColorChange (Cavex Holland BV), Hydrogum 5 (Zhermack Spa), and Moldeer Fast (DFL). Ten impressions were obtained per group according to the manufacturers’ instructions and scanned using an intraoral scanner at predetermined intervals (0 h, 24 h, 48 h, 72 h, 96 h, and 120 h). Impressions were stored under controlled temperature and humidity conditions. Four linear measurements were performed on color-masked images in a blind manner to assess dimensional changes over time: a) intercanine distance, b) intermolar distance, c) right canine-to-molar distance, and d) left canine-to-molar distance. Data were analyzed using repeated-measures ANOVA (α = 0.05). All materials exhibited minor dimensional changes, consisting predominantly of slight contraction. However, no statistically significant differences were observed over time (p > 0.05). Moldeer Fast therefore exhibited dimensional stability comparable to that of ColorChange and Hydrogum 5. All materials maintained clinically acceptable dimensional stability for up to five days, supporting their suitability for delayed digital scanning of irreversible hydrocolloid impressions.
- 22 October 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 173, 107235
Post-curing strategies for enhanced polymerization and color stability in 3D-printed composite crowns
- 22 October 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 173, 107235
Post-curing strategies for enhanced polymerization and color stability in 3D-printed composite crowns