Zhenxin Geng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhenxin Geng has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Jianyuan Xu
School of Electrical Engineering, Shenyang University of Technology, Shenyang 110870, China
2 shared publications - Dongyu Guo
School of Electrical Engineering, Shenyang University of Technology
1 shared publication - Junbo Wang
School of Electrical Engineering, Shenyang University of Technology, Shenyang 110870, China
1 shared publication - Lijuan Liao
State Grid Sichuan Electric Power Company Ziyang Power Supply Company, Ziyang 641300, China
1 shared publication - Xiaolong Li
Shenyang University of Technology
1 shared publication - Xin Lin
Shenyang University of Technology
1 shared publication
Latest Publications
- 29 September 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (39) , 395502
Motion and adsorption: dynamic characteristics and spatial distribution of metallic particle in dry air DC-GIS
Metallic particles within gas-insulated switchgear (GIS) can distort electric fields, leading to gas discharge. Their adsorption onto insulator surface is particularly hazardous, as it can cause flashover and seriously compromise insulation safety. In this study, a transparent conductive scaled GIS busbar is used combined with an object detection model to investigate the motion and adsorption characteristics of linear metallic particle in dry air. Results show that, compared to SF 6 gas, the metallic particle in dry air exhibits higher velocity and a wider range of movement. However, it shows a lower probability of engaging in firefly motion and adsorbing onto insulator surfaces. Under positive polarity, the primary pattern is reciprocating movement. In contrast, under negative polarity, the particle exhibits prolonged swaying firefly motion on the conductor surface. Furthermore, increasing voltage enhances velocity and reduces the likelihood of firefly motion. Additionally, increasing the particle radius decreases firefly motion probability, whereas increasing length leads to the opposite result. Finally, the lifting position has no significant impact. This study supports suppressing metallic particle contamination and optimizing insulation design in dry air DC-GIS.
- 29 September 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (39) , 395502
Motion and adsorption: dynamic characteristics and spatial distribution of metallic particle in dry air DC-GIS
Metallic particles within gas-insulated switchgear (GIS) can distort electric fields, leading to gas discharge. Their adsorption onto insulator surface is particularly hazardous, as it can cause flashover and seriously compromise insulation safety. In this study, a transparent conductive scaled GIS busbar is used combined with an object detection model to investigate the motion and adsorption characteristics of linear metallic particle in dry air. Results show that, compared to SF 6 gas, the metallic particle in dry air exhibits higher velocity and a wider range of movement. However, it shows a lower probability of engaging in firefly motion and adsorbing onto insulator surfaces. Under positive polarity, the primary pattern is reciprocating movement. In contrast, under negative polarity, the particle exhibits prolonged swaying firefly motion on the conductor surface. Furthermore, increasing voltage enhances velocity and reduces the likelihood of firefly motion. Additionally, increasing the particle radius decreases firefly motion probability, whereas increasing length leads to the opposite result. Finally, the lifting position has no significant impact. This study supports suppressing metallic particle contamination and optimizing insulation design in dry air DC-GIS.
- Open Access
Study on Power Frequency Breakdown and Decomposition Characteristics of SF6/N2 Gas Mixture
The SF6/N2 gas mixture is a key eco-friendly alternative to SF6 in power equipment. However, its insulation and decomposition behaviors under realistic conditions of varying pressure and electric field non-uniformity remain insufficiently studied. This study establishes an experimental platform to systematically investigate the power–frequency breakdown and decomposition characteristics of a 3:7 SF6/N2 mixture. Breakdown tests and critical field strength calculations were conducted under different pressures and electric field uniformities, followed by gas composition analysis. Results demonstrate that the proposed critical breakdown field strength method effectively predicts the mixture’s breakdown voltage. Furthermore, a range of decomposition products, including NF3, SOF2, CO2, and C2F6, were identified, whose concentrations generally decreased with rising pressure. These findings provide valuable experimental data and a predictive tool for optimizing the insulation design and condition monitoring of SF6/N2 gas-insulated equipment.
Open AccessStudy on Power Frequency Breakdown and Decomposition Characteristics of SF6/N2 Gas Mixture
The SF6/N2 gas mixture is a key eco-friendly alternative to SF6 in power equipment. However, its insulation and decomposition behaviors under realistic conditions of varying pressure and electric field non-uniformity remain insufficiently studied. This study establishes an experimental platform to systematically investigate the power–frequency breakdown and decomposition characteristics of a 3:7 SF6/N2 mixture. Breakdown tests and critical field strength calculations were conducted under different pressures and electric field uniformities, followed by gas composition analysis. Results demonstrate that the proposed critical breakdown field strength method effectively predicts the mixture’s breakdown voltage. Furthermore, a range of decomposition products, including NF3, SOF2, CO2, and C2F6, were identified, whose concentrations generally decreased with rising pressure. These findings provide valuable experimental data and a predictive tool for optimizing the insulation design and condition monitoring of SF6/N2 gas-insulated equipment.