Ruyu Shang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ruyu Shang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Chao Chen
Beijing Institute of Technology
2 shared publications - Wenzhe Zhang
School of Automation, Beijing Institute of Technology, Beijing, China
2 shared publications - Xiaoyong Sun
Beijing Institute of Technology
2 shared publications Xikai Huang
School of Automation, Beijing Institute of Technology, Beijing, China
2 shared publicationsRuizhao Han
School of Automation, Beijing Institute of Technology, Beijing, China
1 shared publication- Xiangdong Liu
Beijing Institute of Technology
1 shared publication
Latest Publications
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
Fault-Tolerant Control Method of Current Source Inverter-Fed Five-Phase PMSM under Winding Open-Circuit Faults
Five-phase permanent magnet synchronous motors driven by current source inverters are receiving increasing attention in safety-critical applications such as aerospace and automotive systems, due to high torque/power density and excellent fault tolerance. Despite these merits, their vulnerability to faults such as winding open-circuit remains a critical concern. However, limited research has been conducted on single or two-phase (adjacent and non-adjacent) winding open-circuit faults and the resulting neutral-point voltage oscillations. To address this issue, this paper analyzes various winding fault scenarios and reveals the phenomenon and characteristics of neutral-point voltage oscillations. Based on the analyses, a novel fault-tolerant control strategy with neutral-point voltage oscillations compensation is proposed. Firstly, the neutral-point voltage model under fault conditions is established, from which the winding current model and related fault tolerant current expressions are derived. Then, a reduced-order decoupled model is developed. Subsequently, novel space vector pulse width modulation strategies are proposed for various winding fault scenarios. Finally, experimental results validate the proposed strategy. Compared with conventional methods, the fault-tolerant control without neutral-point voltage compensation reduces the torque ripple by 85.6% and 77.2% under adjacent and non-adjacent two-phase faults, respectively. With the compensation method, additional torque ripple reductions of 38.8% and 7.7% are achieved.
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
Fault-Tolerant Control Method of Current Source Inverter-Fed Five-Phase PMSM under Winding Open-Circuit Faults
Five-phase permanent magnet synchronous motors driven by current source inverters are receiving increasing attention in safety-critical applications such as aerospace and automotive systems, due to high torque/power density and excellent fault tolerance. Despite these merits, their vulnerability to faults such as winding open-circuit remains a critical concern. However, limited research has been conducted on single or two-phase (adjacent and non-adjacent) winding open-circuit faults and the resulting neutral-point voltage oscillations. To address this issue, this paper analyzes various winding fault scenarios and reveals the phenomenon and characteristics of neutral-point voltage oscillations. Based on the analyses, a novel fault-tolerant control strategy with neutral-point voltage oscillations compensation is proposed. Firstly, the neutral-point voltage model under fault conditions is established, from which the winding current model and related fault tolerant current expressions are derived. Then, a reduced-order decoupled model is developed. Subsequently, novel space vector pulse width modulation strategies are proposed for various winding fault scenarios. Finally, experimental results validate the proposed strategy. Compared with conventional methods, the fault-tolerant control without neutral-point voltage compensation reduces the torque ripple by 85.6% and 77.2% under adjacent and non-adjacent two-phase faults, respectively. With the compensation method, additional torque ripple reductions of 38.8% and 7.7% are achieved.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3599-3614
A Fault-Tolerant Control Strategy Using Faulty Phase Current Compensation for Five-Phase PMSM Fed by Current-Source Inverters Under Inverter Open-Circuit Faults
Five-phase permanent magnet machines with current source inverters are preferred for safety critical areas, including aerospace and military industries, owing to superior torque density and robust fault tolerance. Despite the advantages, multi-phase machines are not immune to faults, particularly for the inverters due to potential power switches failures. However, in such systems, there has been no research on single-phase and non-adjacent two-phase open-circuit faults of current-source inverters when the non-zero faulty phase winding current is considered. Therefore, this paper analyses and develops a fault-tolerant control strategy with faulty phase winding current compensation to manage the faults. Firstly, the faulty phase winding current model is established, and the fault-tolerant currents are subsequently derived. Then, a reduced-order decoupled mathematical machine model is proposed, and space current vector pulse width modulation methods are introduced for each fault case. Finally, the effectiveness of the control strategy is validated by experimental results. Under single-phase and non-adjacent two-phase open-circuit faults of the inverter, the fault-tolerant strategy with faulty phase winding current compensation can reduce the torque ripple by 14.98% and 23.21% respectively compared with not adopting it.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3599-3614
A Fault-Tolerant Control Strategy Using Faulty Phase Current Compensation for Five-Phase PMSM Fed by Current-Source Inverters Under Inverter Open-Circuit Faults
Five-phase permanent magnet machines with current source inverters are preferred for safety critical areas, including aerospace and military industries, owing to superior torque density and robust fault tolerance. Despite the advantages, multi-phase machines are not immune to faults, particularly for the inverters due to potential power switches failures. However, in such systems, there has been no research on single-phase and non-adjacent two-phase open-circuit faults of current-source inverters when the non-zero faulty phase winding current is considered. Therefore, this paper analyses and develops a fault-tolerant control strategy with faulty phase winding current compensation to manage the faults. Firstly, the faulty phase winding current model is established, and the fault-tolerant currents are subsequently derived. Then, a reduced-order decoupled mathematical machine model is proposed, and space current vector pulse width modulation methods are introduced for each fault case. Finally, the effectiveness of the control strategy is validated by experimental results. Under single-phase and non-adjacent two-phase open-circuit faults of the inverter, the fault-tolerant strategy with faulty phase winding current compensation can reduce the torque ripple by 14.98% and 23.21% respectively compared with not adopting it.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (6) , 12924-12938
Comparative Study of Field Back EMF Ripple in Partitioned Stator Hybrid Excited Machines
Although the field winding can help to regulate the air-gap flux, the back electromotive force (back EMF) induced in the field winding significantly affects the overall performance of hybrid excited (HE) machine systems, including flux-regulation capability, torque–speed characteristics, losses, torque ripples, and safe/stable operation. This article focuses on comparative analysis and suppression of the field back EMF ripple in partitioned stator HE machines (PS-HEMs) having different inner stator configurations. The field back EMF ripples of different machines are comprehensively compared under ideal current source excitations and pulsewidth modulation (PWM)-controlled voltage source converter excitations. The results indicate that the low-order field back EMF harmonics can be effectively reduced by appropriate designs of inner stator topology, field winding configuration, and stator/rotor pole number combinations. Besides, a novel dual-shaping technique of cup rotor is proposed and proved to be effective for the low-order field back EMF harmonics suppression. Moreover, a field-circuit coupled model is built to reveal the influence of PWM harmonics on the overall performance of the machine system, with particular emphasis on their impacts on the field back EMF ripple. Finally, the finite-element (FE) analyses are verified by the experimental results of a partitioned stator (PS) prototype machine having a switched-flux type hybrid-excited inner stator.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (6) , 12924-12938
Comparative Study of Field Back EMF Ripple in Partitioned Stator Hybrid Excited Machines
Although the field winding can help to regulate the air-gap flux, the back electromotive force (back EMF) induced in the field winding significantly affects the overall performance of hybrid excited (HE) machine systems, including flux-regulation capability, torque–speed characteristics, losses, torque ripples, and safe/stable operation. This article focuses on comparative analysis and suppression of the field back EMF ripple in partitioned stator HE machines (PS-HEMs) having different inner stator configurations. The field back EMF ripples of different machines are comprehensively compared under ideal current source excitations and pulsewidth modulation (PWM)-controlled voltage source converter excitations. The results indicate that the low-order field back EMF harmonics can be effectively reduced by appropriate designs of inner stator topology, field winding configuration, and stator/rotor pole number combinations. Besides, a novel dual-shaping technique of cup rotor is proposed and proved to be effective for the low-order field back EMF harmonics suppression. Moreover, a field-circuit coupled model is built to reveal the influence of PWM harmonics on the overall performance of the machine system, with particular emphasis on their impacts on the field back EMF ripple. Finally, the finite-element (FE) analyses are verified by the experimental results of a partitioned stator (PS) prototype machine having a switched-flux type hybrid-excited inner stator.