Wenzhe Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wenzhe Zhang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Chao Chen
Beijing Institute of Technology
2 shared publications - Ruyu Shang
School of Automation, Beijing Institute of Technology, Beijing, China
2 shared publications Xikai Huang
School of Automation, Beijing Institute of Technology, Beijing, China
2 shared publications- Xiangdong Liu
Beijing Institute of Technology
1 shared publication Xiaoyong Sun
School of Automation, Beijing Institute of Technology, Beijing, China
1 shared publication- Xiaoyong Sun
Beijing Institute of Technology
1 shared publication
Latest Publications
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
Fault-Tolerant Control Method of Current Source Inverter-Fed Five-Phase PMSM under Winding Open-Circuit Faults
Five-phase permanent magnet synchronous motors driven by current source inverters are receiving increasing attention in safety-critical applications such as aerospace and automotive systems, due to high torque/power density and excellent fault tolerance. Despite these merits, their vulnerability to faults such as winding open-circuit remains a critical concern. However, limited research has been conducted on single or two-phase (adjacent and non-adjacent) winding open-circuit faults and the resulting neutral-point voltage oscillations. To address this issue, this paper analyzes various winding fault scenarios and reveals the phenomenon and characteristics of neutral-point voltage oscillations. Based on the analyses, a novel fault-tolerant control strategy with neutral-point voltage oscillations compensation is proposed. Firstly, the neutral-point voltage model under fault conditions is established, from which the winding current model and related fault tolerant current expressions are derived. Then, a reduced-order decoupled model is developed. Subsequently, novel space vector pulse width modulation strategies are proposed for various winding fault scenarios. Finally, experimental results validate the proposed strategy. Compared with conventional methods, the fault-tolerant control without neutral-point voltage compensation reduces the torque ripple by 85.6% and 77.2% under adjacent and non-adjacent two-phase faults, respectively. With the compensation method, additional torque ripple reductions of 38.8% and 7.7% are achieved.
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
Fault-Tolerant Control Method of Current Source Inverter-Fed Five-Phase PMSM under Winding Open-Circuit Faults
Five-phase permanent magnet synchronous motors driven by current source inverters are receiving increasing attention in safety-critical applications such as aerospace and automotive systems, due to high torque/power density and excellent fault tolerance. Despite these merits, their vulnerability to faults such as winding open-circuit remains a critical concern. However, limited research has been conducted on single or two-phase (adjacent and non-adjacent) winding open-circuit faults and the resulting neutral-point voltage oscillations. To address this issue, this paper analyzes various winding fault scenarios and reveals the phenomenon and characteristics of neutral-point voltage oscillations. Based on the analyses, a novel fault-tolerant control strategy with neutral-point voltage oscillations compensation is proposed. Firstly, the neutral-point voltage model under fault conditions is established, from which the winding current model and related fault tolerant current expressions are derived. Then, a reduced-order decoupled model is developed. Subsequently, novel space vector pulse width modulation strategies are proposed for various winding fault scenarios. Finally, experimental results validate the proposed strategy. Compared with conventional methods, the fault-tolerant control without neutral-point voltage compensation reduces the torque ripple by 85.6% and 77.2% under adjacent and non-adjacent two-phase faults, respectively. With the compensation method, additional torque ripple reductions of 38.8% and 7.7% are achieved.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3599-3614
A Fault-Tolerant Control Strategy Using Faulty Phase Current Compensation for Five-Phase PMSM Fed by Current-Source Inverters Under Inverter Open-Circuit Faults
Five-phase permanent magnet machines with current source inverters are preferred for safety critical areas, including aerospace and military industries, owing to superior torque density and robust fault tolerance. Despite the advantages, multi-phase machines are not immune to faults, particularly for the inverters due to potential power switches failures. However, in such systems, there has been no research on single-phase and non-adjacent two-phase open-circuit faults of current-source inverters when the non-zero faulty phase winding current is considered. Therefore, this paper analyses and develops a fault-tolerant control strategy with faulty phase winding current compensation to manage the faults. Firstly, the faulty phase winding current model is established, and the fault-tolerant currents are subsequently derived. Then, a reduced-order decoupled mathematical machine model is proposed, and space current vector pulse width modulation methods are introduced for each fault case. Finally, the effectiveness of the control strategy is validated by experimental results. Under single-phase and non-adjacent two-phase open-circuit faults of the inverter, the fault-tolerant strategy with faulty phase winding current compensation can reduce the torque ripple by 14.98% and 23.21% respectively compared with not adopting it.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3599-3614
A Fault-Tolerant Control Strategy Using Faulty Phase Current Compensation for Five-Phase PMSM Fed by Current-Source Inverters Under Inverter Open-Circuit Faults
Five-phase permanent magnet machines with current source inverters are preferred for safety critical areas, including aerospace and military industries, owing to superior torque density and robust fault tolerance. Despite the advantages, multi-phase machines are not immune to faults, particularly for the inverters due to potential power switches failures. However, in such systems, there has been no research on single-phase and non-adjacent two-phase open-circuit faults of current-source inverters when the non-zero faulty phase winding current is considered. Therefore, this paper analyses and develops a fault-tolerant control strategy with faulty phase winding current compensation to manage the faults. Firstly, the faulty phase winding current model is established, and the fault-tolerant currents are subsequently derived. Then, a reduced-order decoupled mathematical machine model is proposed, and space current vector pulse width modulation methods are introduced for each fault case. Finally, the effectiveness of the control strategy is validated by experimental results. Under single-phase and non-adjacent two-phase open-circuit faults of the inverter, the fault-tolerant strategy with faulty phase winding current compensation can reduce the torque ripple by 14.98% and 23.21% respectively compared with not adopting it.