Chao Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chao Chen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Zhen Chen
Beijing Institute of Technology
7 shared publications - Xiangdong Liu
Beijing Institute of Technology
6 shared publications - Xiaoyong Sun
Beijing Institute of Technology
6 shared publications - Zi Qiang Zhu
Department of Electrical and Electronic Engineering, The Hong Kong Polytechnic University, Hong Kong, China
4 shared publications - Ruyu Shang
School of Automation, Beijing Institute of Technology, Beijing, China
2 shared publications - Wenzhe Zhang
School of Automation, Beijing Institute of Technology, Beijing, China
2 shared publications
Latest Publications
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
Fault-Tolerant Control Method of Current Source Inverter-Fed Five-Phase PMSM under Winding Open-Circuit Faults
Five-phase permanent magnet synchronous motors driven by current source inverters are receiving increasing attention in safety-critical applications such as aerospace and automotive systems, due to high torque/power density and excellent fault tolerance. Despite these merits, their vulnerability to faults such as winding open-circuit remains a critical concern. However, limited research has been conducted on single or two-phase (adjacent and non-adjacent) winding open-circuit faults and the resulting neutral-point voltage oscillations. To address this issue, this paper analyzes various winding fault scenarios and reveals the phenomenon and characteristics of neutral-point voltage oscillations. Based on the analyses, a novel fault-tolerant control strategy with neutral-point voltage oscillations compensation is proposed. Firstly, the neutral-point voltage model under fault conditions is established, from which the winding current model and related fault tolerant current expressions are derived. Then, a reduced-order decoupled model is developed. Subsequently, novel space vector pulse width modulation strategies are proposed for various winding fault scenarios. Finally, experimental results validate the proposed strategy. Compared with conventional methods, the fault-tolerant control without neutral-point voltage compensation reduces the torque ripple by 85.6% and 77.2% under adjacent and non-adjacent two-phase faults, respectively. With the compensation method, additional torque ripple reductions of 38.8% and 7.7% are achieved.
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
Fault-Tolerant Control Method of Current Source Inverter-Fed Five-Phase PMSM under Winding Open-Circuit Faults
Five-phase permanent magnet synchronous motors driven by current source inverters are receiving increasing attention in safety-critical applications such as aerospace and automotive systems, due to high torque/power density and excellent fault tolerance. Despite these merits, their vulnerability to faults such as winding open-circuit remains a critical concern. However, limited research has been conducted on single or two-phase (adjacent and non-adjacent) winding open-circuit faults and the resulting neutral-point voltage oscillations. To address this issue, this paper analyzes various winding fault scenarios and reveals the phenomenon and characteristics of neutral-point voltage oscillations. Based on the analyses, a novel fault-tolerant control strategy with neutral-point voltage oscillations compensation is proposed. Firstly, the neutral-point voltage model under fault conditions is established, from which the winding current model and related fault tolerant current expressions are derived. Then, a reduced-order decoupled model is developed. Subsequently, novel space vector pulse width modulation strategies are proposed for various winding fault scenarios. Finally, experimental results validate the proposed strategy. Compared with conventional methods, the fault-tolerant control without neutral-point voltage compensation reduces the torque ripple by 85.6% and 77.2% under adjacent and non-adjacent two-phase faults, respectively. With the compensation method, additional torque ripple reductions of 38.8% and 7.7% are achieved.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- p. 1-13
Compensation Control for Cross-Coupling Effect of Faulty-Phase Winding Currents and Neutral-Voltage Oscillations in CSI-Fed Five-Phase PMSM Under Open-Circuit Faults
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- p. 1-13
Compensation Control for Cross-Coupling Effect of Faulty-Phase Winding Currents and Neutral-Voltage Oscillations in CSI-Fed Five-Phase PMSM Under Open-Circuit Faults
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3599-3614
A Fault-Tolerant Control Strategy Using Faulty Phase Current Compensation for Five-Phase PMSM Fed by Current-Source Inverters Under Inverter Open-Circuit Faults
Five-phase permanent magnet machines with current source inverters are preferred for safety critical areas, including aerospace and military industries, owing to superior torque density and robust fault tolerance. Despite the advantages, multi-phase machines are not immune to faults, particularly for the inverters due to potential power switches failures. However, in such systems, there has been no research on single-phase and non-adjacent two-phase open-circuit faults of current-source inverters when the non-zero faulty phase winding current is considered. Therefore, this paper analyses and develops a fault-tolerant control strategy with faulty phase winding current compensation to manage the faults. Firstly, the faulty phase winding current model is established, and the fault-tolerant currents are subsequently derived. Then, a reduced-order decoupled mathematical machine model is proposed, and space current vector pulse width modulation methods are introduced for each fault case. Finally, the effectiveness of the control strategy is validated by experimental results. Under single-phase and non-adjacent two-phase open-circuit faults of the inverter, the fault-tolerant strategy with faulty phase winding current compensation can reduce the torque ripple by 14.98% and 23.21% respectively compared with not adopting it.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3599-3614
A Fault-Tolerant Control Strategy Using Faulty Phase Current Compensation for Five-Phase PMSM Fed by Current-Source Inverters Under Inverter Open-Circuit Faults
Five-phase permanent magnet machines with current source inverters are preferred for safety critical areas, including aerospace and military industries, owing to superior torque density and robust fault tolerance. Despite the advantages, multi-phase machines are not immune to faults, particularly for the inverters due to potential power switches failures. However, in such systems, there has been no research on single-phase and non-adjacent two-phase open-circuit faults of current-source inverters when the non-zero faulty phase winding current is considered. Therefore, this paper analyses and develops a fault-tolerant control strategy with faulty phase winding current compensation to manage the faults. Firstly, the faulty phase winding current model is established, and the fault-tolerant currents are subsequently derived. Then, a reduced-order decoupled mathematical machine model is proposed, and space current vector pulse width modulation methods are introduced for each fault case. Finally, the effectiveness of the control strategy is validated by experimental results. Under single-phase and non-adjacent two-phase open-circuit faults of the inverter, the fault-tolerant strategy with faulty phase winding current compensation can reduce the torque ripple by 14.98% and 23.21% respectively compared with not adopting it.
- 16 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (3) , 7697-7709
Fault-Tolerant Control With Faulty Phase Winding Currents Compensation for Current Source Inverter-Fed Five-Phase PMSM Under Adjacent Double-Phase Open-Circuit Fault
Multiphase permanent magnet synchronous motors (PMSMs) driven by the current source inverters (CSIs) are widely used in safety-critical applications, due to their fault-tolerant capability and high torque/power density. Nevertheless, the fault-tolerant field-oriented control method based on reduced order transformation matrices for addressing the adjacent double-phase open-circuit fault (ADP-OCF) in the CSI has not yet been established. Moreover, the influence of faulty phase winding currents has not been analyzed and suppressed. Hence, this article develops a fault-tolerant control approach that includes compensation for faulty phase winding currents in the case of ADP-OCF in the CSI. First, the optimized fault-tolerant winding currents are derived. Subsequently, the decoupled mathematical model and fault-tolerant space-vector-pulsewidth-modulation (PWM) strategy are established, and finally the fault-tolerant control is achieved. The effectiveness of the proposed fault-tolerant control scheme has been validated in the experimental results. Additionally, the utilization of compensating for faulty phase winding currents can lead to a further reduction in electromagnetic torque ripple by 19.32%.
- 16 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (3) , 7697-7709
Fault-Tolerant Control With Faulty Phase Winding Currents Compensation for Current Source Inverter-Fed Five-Phase PMSM Under Adjacent Double-Phase Open-Circuit Fault
Multiphase permanent magnet synchronous motors (PMSMs) driven by the current source inverters (CSIs) are widely used in safety-critical applications, due to their fault-tolerant capability and high torque/power density. Nevertheless, the fault-tolerant field-oriented control method based on reduced order transformation matrices for addressing the adjacent double-phase open-circuit fault (ADP-OCF) in the CSI has not yet been established. Moreover, the influence of faulty phase winding currents has not been analyzed and suppressed. Hence, this article develops a fault-tolerant control approach that includes compensation for faulty phase winding currents in the case of ADP-OCF in the CSI. First, the optimized fault-tolerant winding currents are derived. Subsequently, the decoupled mathematical model and fault-tolerant space-vector-pulsewidth-modulation (PWM) strategy are established, and finally the fault-tolerant control is achieved. The effectiveness of the proposed fault-tolerant control scheme has been validated in the experimental results. Additionally, the utilization of compensating for faulty phase winding currents can lead to a further reduction in electromagnetic torque ripple by 19.32%.
- 11 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (2) , 5348-5364
Compensation Control Method of Asymmetric Capacitive Filter for Permanent Magnet Synchronous Motor Fed With Current-Source Inverter
Due to system faults, manufacturing imperfections, assembly tolerances, and operational conditions, the filter capacitors of current-source inverters (CSIs) for permanent magnet synchronous motor drives may be asymmetric in real systems, which results in significant torque ripples. To deal with this issue, this article first studies the influence of asymmetric capacitive filters on torque ripples and then proposes three compensation control schemes. Based on the phasor method, the motor currents under asymmetric capacitive filters are first obtained. Then, the torque ripples can be reduced by eliminating the negative-sequence currents (NSCs), which can be achieved by PI controller (NSC-PI), the calculating compensation matrices (NSC-CM-Calculation), and the measuring compensation matrices (NSC-CM-Measured). The control scheme based on NSC-CM-Measured has the best compensation performance among these three methods. However, it requires the measurement of compensation coefficients and d- and q-Axis currents caused by back electromotive forces (back EMFs). It shows that the control scheme based on NSC-CM-Calculation has good compensation performance and fast dynamic performance and can be extended to other asymmetric conditions easily, such as open-circuit filter capacitor conditions. Finally, the experimental results have verified the effectiveness of the proposed compensation schemes.
- 11 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (2) , 5348-5364
Compensation Control Method of Asymmetric Capacitive Filter for Permanent Magnet Synchronous Motor Fed With Current-Source Inverter
Due to system faults, manufacturing imperfections, assembly tolerances, and operational conditions, the filter capacitors of current-source inverters (CSIs) for permanent magnet synchronous motor drives may be asymmetric in real systems, which results in significant torque ripples. To deal with this issue, this article first studies the influence of asymmetric capacitive filters on torque ripples and then proposes three compensation control schemes. Based on the phasor method, the motor currents under asymmetric capacitive filters are first obtained. Then, the torque ripples can be reduced by eliminating the negative-sequence currents (NSCs), which can be achieved by PI controller (NSC-PI), the calculating compensation matrices (NSC-CM-Calculation), and the measuring compensation matrices (NSC-CM-Measured). The control scheme based on NSC-CM-Measured has the best compensation performance among these three methods. However, it requires the measurement of compensation coefficients and d- and q-Axis currents caused by back electromotive forces (back EMFs). It shows that the control scheme based on NSC-CM-Calculation has good compensation performance and fast dynamic performance and can be extended to other asymmetric conditions easily, such as open-circuit filter capacitor conditions. Finally, the experimental results have verified the effectiveness of the proposed compensation schemes.
- 30 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (3) , 1547-1571
Torque Ripple Suppression With Compensation Control Method for Permanent Magnet Synchronous Motor With Asymmetric Magnetomotive Force
Due to manufacturing imperfections and assembly tolerances (MIAT), the actual motor inevitably deviates from the desired motor, which may significantly degrade its performance. To ease the influence of MIAT, researchers have studied both motor design and compensation control methods. Compared with the motor design method, compensation control is more cost-effective and flexible but has not been well investigated, especially for motors experiencing asymmetric magnetomotive force (AMMF) due to MIAT. The main purpose of this paper is to suppress the torque ripple for permanent magnet synchronous motor under AMMF caused by MIAT using the compensation control method. This paper firstly analyzes the influence of AMMF on electromagnetic torque performance, then derives the compensation currents for torque ripple suppression. Subsequently, a modified field-oriented-control is established. Moreover, it is found that MIAT can cause neutral voltage oscillation, which significantly affects the current tracking performance. Therefore, a novel space-vector-pulse-width-modulation is proposed to ease the influence of neutral voltage oscillation. The experiments confirmed that the proposed method can reduce the torque ripple by 87.8% and 80.8% during speed acceleration and steady state, respectively. Furthermore, this method has the advantages of better dynamic performance, improved frequency spectrum performance, and higher motor efficiency at high speeds.
- 30 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (3) , 1547-1571
Torque Ripple Suppression With Compensation Control Method for Permanent Magnet Synchronous Motor With Asymmetric Magnetomotive Force
Due to manufacturing imperfections and assembly tolerances (MIAT), the actual motor inevitably deviates from the desired motor, which may significantly degrade its performance. To ease the influence of MIAT, researchers have studied both motor design and compensation control methods. Compared with the motor design method, compensation control is more cost-effective and flexible but has not been well investigated, especially for motors experiencing asymmetric magnetomotive force (AMMF) due to MIAT. The main purpose of this paper is to suppress the torque ripple for permanent magnet synchronous motor under AMMF caused by MIAT using the compensation control method. This paper firstly analyzes the influence of AMMF on electromagnetic torque performance, then derives the compensation currents for torque ripple suppression. Subsequently, a modified field-oriented-control is established. Moreover, it is found that MIAT can cause neutral voltage oscillation, which significantly affects the current tracking performance. Therefore, a novel space-vector-pulse-width-modulation is proposed to ease the influence of neutral voltage oscillation. The experiments confirmed that the proposed method can reduce the torque ripple by 87.8% and 80.8% during speed acceleration and steady state, respectively. Furthermore, this method has the advantages of better dynamic performance, improved frequency spectrum performance, and higher motor efficiency at high speeds.
- 1 April 2023
- Published by Springer Nature
- p. 649-661
A Novel Self-tuning Speed Control Scheme for the Permanent Magnet Synchronous Motor
- 1 April 2023
- Published by Springer Nature
- p. 649-661
A Novel Self-tuning Speed Control Scheme for the Permanent Magnet Synchronous Motor
- Open Access
An nth Harmonic Current Suppression Method Based on the Impulse Current PWM Technique for a Multi-Phase Permanent Magnet Synchronous Motor Fed with a Current Source Inverter
Among the existing harmonic current suppression methods, it is difficult and complicated to suppress any nth harmonic current accurately for multi-phase permanent magnet synchronous motors (PMSMs). To solve this problem, this paper takes a five-phase dual-rotor PMSM fed with a current source inverter (CSI) as an example, and proposes an nth harmonic current suppression method based on the impulse current PWM algorithm. Firstly, the analysis is conducted and presented for the nth harmonic current in the mth harmonic space. Then, based on the Sliding Discrete Fourier Transformation (SDFT), a low-pass filter (LPF) named SDFT-LPF is designed. Additionally, the impulse current PWM technique for the five-phase CSI is realized. In this paper, the experiments have confirmed that the SDFT-LPF has good filter performance. Compared with the SVPWM, the impulse current PWM technique has the same DC-link current utilization rate, but it is easier to implement. Moreover, the proposed harmonic current control method can accurately control any nth harmonic current without changing the PWM technique, which has significantly reduced the complexity of the harmonic current control. Additionally, the proposed scheme is easy to implement and can be directly extended to the multiple harmonic current’s control.
Open AccessAn nth Harmonic Current Suppression Method Based on the Impulse Current PWM Technique for a Multi-Phase Permanent Magnet Synchronous Motor Fed with a Current Source Inverter
Among the existing harmonic current suppression methods, it is difficult and complicated to suppress any nth harmonic current accurately for multi-phase permanent magnet synchronous motors (PMSMs). To solve this problem, this paper takes a five-phase dual-rotor PMSM fed with a current source inverter (CSI) as an example, and proposes an nth harmonic current suppression method based on the impulse current PWM algorithm. Firstly, the analysis is conducted and presented for the nth harmonic current in the mth harmonic space. Then, based on the Sliding Discrete Fourier Transformation (SDFT), a low-pass filter (LPF) named SDFT-LPF is designed. Additionally, the impulse current PWM technique for the five-phase CSI is realized. In this paper, the experiments have confirmed that the SDFT-LPF has good filter performance. Compared with the SVPWM, the impulse current PWM technique has the same DC-link current utilization rate, but it is easier to implement. Moreover, the proposed harmonic current control method can accurately control any nth harmonic current without changing the PWM technique, which has significantly reduced the complexity of the harmonic current control. Additionally, the proposed scheme is easy to implement and can be directly extended to the multiple harmonic current’s control.