Yungi Yeom
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yungi Yeom has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Moojae Han
Department of Radiation Oncology, Seoul National University Bundang Hospital, 82, Gumi-ro 173, Seongnam, Gyeonggi-do
4 shared publications - Sung Kwang Park
Department of Radiation Oncology, Busan Paik Hospital, Inje University, 75, Bokji-ro, Busan
4 shared publications - Yohan Shin
Department of Radiation Oncology, College of Medicine, Inje University, 75, Bokji-ro, Busan
4 shared publications - Jin Young Kim
Department of Radiation Oncology, Dongnam Institute of Radiological and Medical Sciences, Busan, Korea
2 shared publications - Jin-Beom Chung
Department of Radiation Oncology Seoul National University Bundang Hospital Seongnam Republic of Korea
2 shared publications Heunglae Cho
Department of Radiation Oncology, Busan Paik Hospital, Inje University, Gimhae, Korea
1 shared publication
Latest Publications
- 1 November 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (11) , P11011
Screen-printed inorganic perovskite thick-film sensor for clinical electron beam quality assurance
In the field of radiation therapy, inorganic perovskites, which exhibit excellent radiation responsiveness, are attracting attention as solid-state sensor materials for precise quality assurance (QA). However, conventional nano-scale perovskite thin-films have limitations due to insufficient active volume in measuring high-energy (high-E) radiation characterized by high penetrating power. To overcome these limitations, we fabricated a micro-scale CsPbI 2 Br thick-film sensor and irradiated it with high-E electron beams of 6, 9, and 12 MeV using a clinical linear accelerator under experimental conditions closely simulating a clinical QA environment. The experimental results demonstrated that the fabricated sensor exhibited excellent linearity ( R 2 > 0.999) and repeatability (CV< 1.6%) within the dose range of 10 to 1000 MU. Furthermore, it showed a dose-rate independent response against dose-rate variations from 100 to 600 MU/min. In a comparative evaluation of the percent-depth dose (PDD) against an ionization chamber, the difference in R 50 was less than 1 mm, satisfying the clinical QA tolerance criterion. However, at deeper depths, overestimations were observed due to the photoelectric effect induced by scattered low-energy photons, which was attributed to the high atomic number of the sensor material. Additionally, this study has a limitation in evaluating long-term reliability due to the lack of proper encapsulation. In conclusion, the thick-film sensor fabricated in this study demonstrated outstanding dosimetric response characteristics. With further studies, such as the development of robust packaging techniques and compensation layers, it is highly anticipated to be widely utilized as a next-generation dosimeter for clinical radiotherapy QA.
- 1 November 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (11) , P11011
Screen-printed inorganic perovskite thick-film sensor for clinical electron beam quality assurance
In the field of radiation therapy, inorganic perovskites, which exhibit excellent radiation responsiveness, are attracting attention as solid-state sensor materials for precise quality assurance (QA). However, conventional nano-scale perovskite thin-films have limitations due to insufficient active volume in measuring high-energy (high-E) radiation characterized by high penetrating power. To overcome these limitations, we fabricated a micro-scale CsPbI 2 Br thick-film sensor and irradiated it with high-E electron beams of 6, 9, and 12 MeV using a clinical linear accelerator under experimental conditions closely simulating a clinical QA environment. The experimental results demonstrated that the fabricated sensor exhibited excellent linearity ( R 2 > 0.999) and repeatability (CV< 1.6%) within the dose range of 10 to 1000 MU. Furthermore, it showed a dose-rate independent response against dose-rate variations from 100 to 600 MU/min. In a comparative evaluation of the percent-depth dose (PDD) against an ionization chamber, the difference in R 50 was less than 1 mm, satisfying the clinical QA tolerance criterion. However, at deeper depths, overestimations were observed due to the photoelectric effect induced by scattered low-energy photons, which was attributed to the high atomic number of the sensor material. Additionally, this study has a limitation in evaluating long-term reliability due to the lack of proper encapsulation. In conclusion, the thick-film sensor fabricated in this study demonstrated outstanding dosimetric response characteristics. With further studies, such as the development of robust packaging techniques and compensation layers, it is highly anticipated to be widely utilized as a next-generation dosimeter for clinical radiotherapy QA.
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , P06016
Fundamental properties of a perovskite with low dermal toxicity: potential application for skin dosimetry in radiotherapy
High-energy photon beams are widely used in radiotherapy owing to their effectiveness in treating deep-seated tumors and their skin-sparing effects. However, treatment planning systems — the most common method for estimating skin dose — have been reported to deviate by as much as 34% from measurements, potentially leading to various side effects. To address this issue, numerous studies have explored skin dosimeters for direct skin dose measurement. However, many of these are limited in clinical applicability because they rely on highly toxic materials such as lead and mercury. In this study, a skin dosimeter based on BaTiO 3 — a nearly non-toxic material — was fabricated, and its fundamental response to high-energy photon beams was evaluated to assess its feasibility for practical applications. The dosimeter was tested for linearity, repeatability, dose-rate dependence, and percent-depth-dose (PDD) conformity. The results demonstrated excellent linearity and repeatability, along with consistent performance across varying dose rates. However, although the dosimeter exhibited excellent D max conformity, the PDD 20/10 values exhibited errors greater than 3.4%, which are likely attributed to several factors, including the atomic number and energy dependence of the sensor. These findings suggest that BaTiO 3 possesses favorable electrical characteristics for use as a skin dosimeter and that a clinically viable device may be achievable through further studies.
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , P06016
Fundamental properties of a perovskite with low dermal toxicity: potential application for skin dosimetry in radiotherapy
High-energy photon beams are widely used in radiotherapy owing to their effectiveness in treating deep-seated tumors and their skin-sparing effects. However, treatment planning systems — the most common method for estimating skin dose — have been reported to deviate by as much as 34% from measurements, potentially leading to various side effects. To address this issue, numerous studies have explored skin dosimeters for direct skin dose measurement. However, many of these are limited in clinical applicability because they rely on highly toxic materials such as lead and mercury. In this study, a skin dosimeter based on BaTiO 3 — a nearly non-toxic material — was fabricated, and its fundamental response to high-energy photon beams was evaluated to assess its feasibility for practical applications. The dosimeter was tested for linearity, repeatability, dose-rate dependence, and percent-depth-dose (PDD) conformity. The results demonstrated excellent linearity and repeatability, along with consistent performance across varying dose rates. However, although the dosimeter exhibited excellent D max conformity, the PDD 20/10 values exhibited errors greater than 3.4%, which are likely attributed to several factors, including the atomic number and energy dependence of the sensor. These findings suggest that BaTiO 3 possesses favorable electrical characteristics for use as a skin dosimeter and that a clinically viable device may be achievable through further studies.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04021
Exploring CsPbIBr 2 -based Sensor for clinical QA of therapeutic electron beam
Quality assurance (QA) in radiotherapy is essential to ensure precise dose delivery; however, conventional ionization chambers, including parallel plate chambers (PPCs), exhibit inherent structural limitations, particularly under small-field conditions. In this study, a CsPbIBr 2 -based unit-cell radiation sensor utilizing a halide perovskite material was fabricated, leveraging its capability for compact thin-film construction. The response characteristics of the sensor to high-energy electron beams (6, 9, and 12 MeV) generated by a clinical linear accelerator were systematically evaluated to assess its suitability as a clinical QA dosimeter. The fabricated sensor demonstrated stable linearity and repeatability across various irradiation conditions, maintaining consistent performance regardless of dose-rate variations. Furthermore, electron beam-quality indices derived from depth-dose curve analyses closely matched the reference values obtained with a PPC, satisfying established tolerance criteria for clinical electron beam-quality QA. These findings indicate that the CsPbIBr 2 -based sensor offers reliable and stable dosimetric performance in clinical electron beam QA settings. However, increasing deviation was observed in the low-energy region under certain conditions, which was potentially attributable to low-energy photon influence. Addressing this limitation through further investigation is necessary. With continued development, the proposed sensor holds promise as a practical dosimeter for clinical QA applications.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04021
Exploring CsPbIBr 2 -based Sensor for clinical QA of therapeutic electron beam
Quality assurance (QA) in radiotherapy is essential to ensure precise dose delivery; however, conventional ionization chambers, including parallel plate chambers (PPCs), exhibit inherent structural limitations, particularly under small-field conditions. In this study, a CsPbIBr 2 -based unit-cell radiation sensor utilizing a halide perovskite material was fabricated, leveraging its capability for compact thin-film construction. The response characteristics of the sensor to high-energy electron beams (6, 9, and 12 MeV) generated by a clinical linear accelerator were systematically evaluated to assess its suitability as a clinical QA dosimeter. The fabricated sensor demonstrated stable linearity and repeatability across various irradiation conditions, maintaining consistent performance regardless of dose-rate variations. Furthermore, electron beam-quality indices derived from depth-dose curve analyses closely matched the reference values obtained with a PPC, satisfying established tolerance criteria for clinical electron beam-quality QA. These findings indicate that the CsPbIBr 2 -based sensor offers reliable and stable dosimetric performance in clinical electron beam QA settings. However, increasing deviation was observed in the low-energy region under certain conditions, which was potentially attributable to low-energy photon influence. Addressing this limitation through further investigation is necessary. With continued development, the proposed sensor holds promise as a practical dosimeter for clinical QA applications.
- 1 November 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (11) , P11022
Feasibility of CsPbI 2 Cl perovskite for quality assurance in radiation therapy
CsPb-based perovskites are promising materials for solar cells because of their low unit production cost and high efficiency. Among them, halide materials have also attracted research attention in the field of radiation therapy. In this study, we analyzed the characteristics of CsPbI 2 Cl — a CsPb-based halide perovskite — under high-energy radiation at levels equivalent to those used in clinical therapy to evaluate its feasibility for quality assurance (QA) in radiation therapy. We fabricated a CsPbI 2 Cl-based sensor after synthesizing CsPbI 2 Cl from its precursors, i.e., CsCl and PbI 2 , and evaluated the linearity, repeatability, dose-rate dependence, and percent depth dose (PDD) under irradiation with energy of 6 and 15 MV. All the evaluated parameters except for the PDD met the criteria ( R 2 > 0.99900 and CV< 1.5%). However, PDD 20/10 , which is one of the criteria for PDD, exhibited errors of 6.34% and 3.74% for 6 and 15 MV, respectively, compared with the ionization chamber, which provides the reference value for actual QA. This may be due to the unique response characteristics of semiconductor-based dosimeters and the high atomic number of the components of CsPbI 2 Cl. According to the results, the CsPbI 2 Cl-based sensor developed in this study was evaluated for its reliability and stability against high-energy radiation, but it still needs to be improved for depth-dose measurement. With follow-up studies for improving the sensor structure and considering additional variables, we expect that this sensor can be employed as a dosimeter for clinical QA.
- 1 November 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (11) , P11022
Feasibility of CsPbI 2 Cl perovskite for quality assurance in radiation therapy
CsPb-based perovskites are promising materials for solar cells because of their low unit production cost and high efficiency. Among them, halide materials have also attracted research attention in the field of radiation therapy. In this study, we analyzed the characteristics of CsPbI 2 Cl — a CsPb-based halide perovskite — under high-energy radiation at levels equivalent to those used in clinical therapy to evaluate its feasibility for quality assurance (QA) in radiation therapy. We fabricated a CsPbI 2 Cl-based sensor after synthesizing CsPbI 2 Cl from its precursors, i.e., CsCl and PbI 2 , and evaluated the linearity, repeatability, dose-rate dependence, and percent depth dose (PDD) under irradiation with energy of 6 and 15 MV. All the evaluated parameters except for the PDD met the criteria ( R 2 > 0.99900 and CV< 1.5%). However, PDD 20/10 , which is one of the criteria for PDD, exhibited errors of 6.34% and 3.74% for 6 and 15 MV, respectively, compared with the ionization chamber, which provides the reference value for actual QA. This may be due to the unique response characteristics of semiconductor-based dosimeters and the high atomic number of the components of CsPbI 2 Cl. According to the results, the CsPbI 2 Cl-based sensor developed in this study was evaluated for its reliability and stability against high-energy radiation, but it still needs to be improved for depth-dose measurement. With follow-up studies for improving the sensor structure and considering additional variables, we expect that this sensor can be employed as a dosimeter for clinical QA.