Ruobing Qian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ruobing Qian has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Edouard Berrocal
Lund University
2 shared publications - Haoqian Wang
Tsinghua University, Shenzhen, China
2 shared publications - Joakim Jönsson
Department of Biomedical Engineering, Duke University, Durham, NC, United States
2 shared publications - Joseph A. Izatt
Department of Biomedical Engineering, Duke University, Durham, NC, USA
2 shared publications - Kanghyun Kim
Department of Biomedical Engineering, Duke University, Durham, NC, United States of America
2 shared publications - Kevin C. Zhou
Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, USA
2 shared publications
Latest Publications
- Open Access
- 8 July 2022
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 16, 908770
Transient Motion Classification Through Turbid Volumes via Parallelized Single-Photon Detection and Deep Contrastive Embedding
Fast noninvasive probing of spatially varying decorrelating events, such as cerebral blood flow beneath the human skull, is an essential task in various scientific and clinical settings. One of the primary optical techniques used is diffuse correlation spectroscopy (DCS), whose classical implementation uses a single or few single-photon detectors, resulting in poor spatial localization accuracy and relatively low temporal resolution. Here, we propose a technique termed ClassifyingRapid decorrelationEvents viaParallelized single photon dEtection (CREPE), a new form of DCS that can probe and classify different decorrelating movements hidden underneath turbid volume with high sensitivity using parallelized speckle detection from a 32 × 32 pixel SPAD array. We evaluate our setup by classifying different spatiotemporal-decorrelating patterns hidden beneath a 5 mm tissue-like phantom made with rapidly decorrelating dynamic scattering media. Twelve multi-mode fibers are used to collect scattered light from different positions on the surface of the tissue phantom. To validate our setup, we generate perturbed decorrelation patterns by both a digital micromirror device (DMD) modulated at multi-kilo-hertz rates, as well as a vessel phantom containing flowing fluid. Along with a deep contrastive learning algorithm that outperforms classic unsupervised learning methods, we demonstrate our approach can accurately detect and classify different transient decorrelation events (happening in 0.1–0.4 s) underneath turbid scattering media, without any data labeling. This has the potential to be applied to non-invasively monitor deep tissue motion patterns, for example identifying normal or abnormal cerebral blood flow events, at multi-Hertz rates within a compact and static detection probe.
- 8 July 2022
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 16, 908770
Open AccessTransient Motion Classification Through Turbid Volumes via Parallelized Single-Photon Detection and Deep Contrastive Embedding
Fast noninvasive probing of spatially varying decorrelating events, such as cerebral blood flow beneath the human skull, is an essential task in various scientific and clinical settings. One of the primary optical techniques used is diffuse correlation spectroscopy (DCS), whose classical implementation uses a single or few single-photon detectors, resulting in poor spatial localization accuracy and relatively low temporal resolution. Here, we propose a technique termed ClassifyingRapid decorrelationEvents viaParallelized single photon dEtection (CREPE), a new form of DCS that can probe and classify different decorrelating movements hidden underneath turbid volume with high sensitivity using parallelized speckle detection from a 32 × 32 pixel SPAD array. We evaluate our setup by classifying different spatiotemporal-decorrelating patterns hidden beneath a 5 mm tissue-like phantom made with rapidly decorrelating dynamic scattering media. Twelve multi-mode fibers are used to collect scattered light from different positions on the surface of the tissue phantom. To validate our setup, we generate perturbed decorrelation patterns by both a digital micromirror device (DMD) modulated at multi-kilo-hertz rates, as well as a vessel phantom containing flowing fluid. Along with a deep contrastive learning algorithm that outperforms classic unsupervised learning methods, we demonstrate our approach can accurately detect and classify different transient decorrelation events (happening in 0.1–0.4 s) underneath turbid scattering media, without any data labeling. This has the potential to be applied to non-invasively monitor deep tissue motion patterns, for example identifying normal or abnormal cerebral blood flow events, at multi-Hertz rates within a compact and static detection probe.
- Open Access
Transient motion classification through turbid volumes via parallelized single-photon detection and deep contrastive embedding
Fast noninvasive probing of spatially varying decorrelating events, such as cerebral blood flow beneath the human skull, is an essential task in various scientific and clinical settings. One of the primary optical techniques used is diffuse correlation spectroscopy (DCS), whose classical implementation uses a single or few single-photon detectors, resulting in poor spatial localization accuracy and relatively low temporal resolution. Here, we propose a technique termed Classifying Rapid decorrelation Events via Parallelized single photon dEtection (CREPE)}, a new form of DCS that can probe and classify different decorrelating movements hidden underneath turbid volume with high sensitivity using parallelized speckle detection from a $32\times32$ pixel SPAD array. We evaluate our setup by classifying different spatiotemporal-decorrelating patterns hidden beneath a 5mm tissue-like phantom made with rapidly decorrelating dynamic scattering media. Twelve multi-mode fibers are used to collect scattered light from different positions on the surface of the tissue phantom. To validate our setup, we generate perturbed decorrelation patterns by both a digital micromirror device (DMD) modulated at multi-kilo-hertz rates, as well as a vessel phantom containing flowing fluid. Along with a deep contrastive learning algorithm that outperforms classic unsupervised learning methods, we demonstrate our approach can accurately detect and classify different transient decorrelation events (happening in 0.1-0.4s) underneath turbid scattering media, without any data labeling. This has the potential to be applied to noninvasively monitor deep tissue motion patterns, for example identifying normal or abnormal cerebral blood flow events, at multi-Hertz rates within a compact and static detection probe.Open AccessTransient motion classification through turbid volumes via parallelized single-photon detection and deep contrastive embedding
Fast noninvasive probing of spatially varying decorrelating events, such as cerebral blood flow beneath the human skull, is an essential task in various scientific and clinical settings. One of the primary optical techniques used is diffuse correlation spectroscopy (DCS), whose classical implementation uses a single or few single-photon detectors, resulting in poor spatial localization accuracy and relatively low temporal resolution. Here, we propose a technique termed Classifying Rapid decorrelation Events via Parallelized single photon dEtection (CREPE)}, a new form of DCS that can probe and classify different decorrelating movements hidden underneath turbid volume with high sensitivity using parallelized speckle detection from a $32\times32$ pixel SPAD array. We evaluate our setup by classifying different spatiotemporal-decorrelating patterns hidden beneath a 5mm tissue-like phantom made with rapidly decorrelating dynamic scattering media. Twelve multi-mode fibers are used to collect scattered light from different positions on the surface of the tissue phantom. To validate our setup, we generate perturbed decorrelation patterns by both a digital micromirror device (DMD) modulated at multi-kilo-hertz rates, as well as a vessel phantom containing flowing fluid. Along with a deep contrastive learning algorithm that outperforms classic unsupervised learning methods, we demonstrate our approach can accurately detect and classify different transient decorrelation events (happening in 0.1-0.4s) underneath turbid scattering media, without any data labeling. This has the potential to be applied to noninvasively monitor deep tissue motion patterns, for example identifying normal or abnormal cerebral blood flow events, at multi-Hertz rates within a compact and static detection probe. - Open Access
- 8 November 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (12) , 7361-7376
Robotically aligned optical coherence tomography with 5 degree of freedom eye tracking for subject motion and gaze compensation
Optical coherence tomography (OCT) has revolutionized diagnostics in ophthalmology. However, OCT requires a trained operator and patient cooperation to carefully align a scanner with the subject’s eye and orient it in such a way that it images a desired region of interest at the retina. With the goal of automating this process of orienting and aligning the scanner, we developed a robot-mounted OCT scanner that automatically aligned with the pupil while matching its optical axis with the target region of interest at the retina. The system used two 3D cameras for face tracking and three high-resolution 2D cameras for pupil and gaze tracking. The tracking software identified 5 degrees of freedom for robot alignment and ray aiming through the ocular pupil: 3 degrees of translation (x, y, z) and 2 degrees of orientation (yaw, pitch). We evaluated the accuracy, precision, and range of our tracking system and demonstrated imaging performance on free-standing human subjects. Our results demonstrate that the system stabilized images and that the addition of gaze tracking and aiming allowed for region-of-interest specific alignment at any gaze orientation within a 28° range.
- 8 November 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (12) , 7361-7376
Open AccessRobotically aligned optical coherence tomography with 5 degree of freedom eye tracking for subject motion and gaze compensation
Optical coherence tomography (OCT) has revolutionized diagnostics in ophthalmology. However, OCT requires a trained operator and patient cooperation to carefully align a scanner with the subject’s eye and orient it in such a way that it images a desired region of interest at the retina. With the goal of automating this process of orienting and aligning the scanner, we developed a robot-mounted OCT scanner that automatically aligned with the pupil while matching its optical axis with the target region of interest at the retina. The system used two 3D cameras for face tracking and three high-resolution 2D cameras for pupil and gaze tracking. The tracking software identified 5 degrees of freedom for robot alignment and ray aiming through the ocular pupil: 3 degrees of translation (x, y, z) and 2 degrees of orientation (yaw, pitch). We evaluated the accuracy, precision, and range of our tracking system and demonstrated imaging performance on free-standing human subjects. Our results demonstrate that the system stabilized images and that the addition of gaze tracking and aiming allowed for region-of-interest specific alignment at any gaze orientation within a 28° range.
- Open Access
- 20 October 2016
- Published by Optica Publishing Group in Optics Letters
- Vol. 41 (21) , 4891-4894
Long working distance OCT with a compact 2f retinal scanning configuration for pediatric imaging
Young and/or autistic children cannot be imaged with tabletop or handheld optical coherence tomography (OCT) because of their lack of attention and fear of large objects close to their face. We demonstrate a prototype retinal swept-source OCT system with a long working distance (from the last optical element to the subject’s eye) to facilitate pediatric imaging. To reduce the number of optical elements and axial length compared to the traditional telescope, we employ a compact retinal scanning configuration and achieve a working distance of 350 mm with a 16° OCT field of view. We test our prototype system on pediatric and adult subjects.- 20 October 2016
- Published by Optica Publishing Group in Optics Letters
- Vol. 41 (21) , 4891-4894
Open AccessLong working distance OCT with a compact 2f retinal scanning configuration for pediatric imaging
Young and/or autistic children cannot be imaged with tabletop or handheld optical coherence tomography (OCT) because of their lack of attention and fear of large objects close to their face. We demonstrate a prototype retinal swept-source OCT system with a long working distance (from the last optical element to the subject’s eye) to facilitate pediatric imaging. To reduce the number of optical elements and axial length compared to the traditional telescope, we employ a compact retinal scanning configuration and achieve a working distance of 350 mm with a 16° OCT field of view. We test our prototype system on pediatric and adult subjects.