TTTumiran Tumiran

Tumiran Tumiran

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tumiran Tumiran has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    AI-Driven Islamic Classroom Management in the Digital Era: The Roles of Neuro-Pedagogy, Spiritual Intelligence, and Innovative Teaching Performance

    by Tumiran Tumiran, Bahtiar Siregar, Sakban Lubis, M. Yunan Harahap, Mhd. Habibu Rahman

    The rapid advancement of digital technologies and artificial intelligence (AI) is reshaping educational systems worldwide, including Islamic education institutions that seek to preserve spiritual and ethical values while embracing pedagogical innovation. This study investigates the influence of digital technology integration, Islamic neuro-pedagogy, classroom environment, and teachers’ spiritual intelligence on Islamic classroom management and innovative teaching performance in madrasahs in Medan City, Indonesia. A quantitative research design was employed using structured questionnaires distributed to 120 teachers, and the collected data were analyzed through path analysis to examine direct and mediating relationships among variables. The findings reveal that Islamic neuro-pedagogy exerts the strongest positive effect on innovative teaching performance (β = 0.268), followed by digital technology integration (β = 0.253). Although classroom environment and spiritual intelligence demonstrate comparatively smaller direct effects, both significantly contribute to effective pedagogical practices and classroom interaction. Furthermore, Islamic classroom management plays a significant mediating role, strengthening the relationship between technological, cognitive, and spiritual dimensions and teachers’ innovative performance. The study proposes a holistic framework for AI-supported Islamic education that integrates neuroscience-informed pedagogy, digital learning technologies, and spiritual intelligence within value-based classroom management practices. These findings contribute theoretically to contemporary Islamic educational research and provide practical implications for educators, curriculum designers, and policymakers seeking to foster innovative, ethical, and spiritually grounded learning environments in the digital era.


  • Open Access

    Analysis of Visible-Light Image and Flashover Voltage on the Cap-and-Pin Insulator With Fan-Shaped Pollution Distribution

    by Mochammad Wahyudi, Tumiran Tumiran, Noor Akhmad Setiawan

    Previous models have examined the relationship between insulator pollution level and flashover voltage, as well as between pollution levels and image-based features. This study investigated the potential correlation between visible-light images and flashover voltage. Porcelain cap-and-pin insulators were contaminated using a modified fan-shaped pollution distribution technique with a low-volume medium-pressure spray gun. Four pollution levels were produced by varying the ash–salt concentration (0.02–0.12 g/mL) and the number of spray gun trigger actuation (2-12). After ultrasonic humidification at 90% relative humidity for 90 min, the AC flashover tests were repeated at each pollution level until ten flashover voltages were obtained. Insulator images were captured under controlled conditions, including illumination (6,000 lm, 6,500 K), exposure parameters (ISO 500, f/16, 1/10 s), imaging geometry (1.3 m distance, 11.5° downward tilt, maximum optical zoom), and in-camera sRGB color space. Image processing involved selecting the fan-shaped area, cropping, background removal, conversion to RGB and HSV stacks, and histogram computation. Pearson’s correlation analysis showed that the histogram peak displacement between the dry and wet conditions of the pollutant layer was the most representative image feature with respect to flashover voltage. The RGB histogram peak displacement exhibited a higher correlation level than HSV, with the red component showing the greatest correlation coefficient (0.82). Furthermore, multivariable linear regression based on RGB histogram peak displacement yielded a coefficient of determination of 0.915. These results indicate that visible-light images can serve as non-contact predictors of the insulator pollution level and flashover voltage.

  • Open Access

    Reactive Power Control Modes in Smart Inverters for Overvoltage Mitigation: Impacts on LVRT Performance—A Case Study in Gorontalo, Indonesia

    by Muammar Zainuddin, M. Isnaeni Bambang Setyonegoro, Eka Firmansyah, Tumiran

    The increasing penetration of photovoltaic (PV) power generation into distribution networks presents an overvoltage challenge during normal operations. Smart inverter reactive power control modes are promising solutions to address this challenge. To mitigate overvoltage, reactive power control modes are commonly configured with conservative limits to protect equipment. However, during severe faults, a higher reactive current availability is required to comply with low-voltage ride-through (LVRT) requirements. Therefore, reactive power control modes should be capable of operating under both normal and fault conditions. This study investigated how the standard reactive power control modes used for overvoltage mitigation affected the LVRT performance. A case study was conducted on a 2 MWp PV plant connected to a real medium-voltage feeder in Gorontalo, Indonesia, which experienced overvoltage during peak PV injection. To assess this impact, a multifunctional control framework was developed that integrated a reactive power controller (Fixed VAr, Fixed power factor, Watt–VAr, and Volt–VAr), fault detection logic, an LVRT mechanism, and a current limiting scheme. Three-phase symmetrical faults were simulated with variations in the reactive power limits, voltage sag depths, and delayed fault clearing. The results showed a clear trade-off: tighter reactive power limits reduced steady-state overvoltage but degraded LVRT performance by lowering reactive current injection and delaying voltage recovery. Moreover, each control mode exhibited distinct dynamic responses, implying different parameter-setting priorities. These findings underscore the need to configure reactive power limits and firmware parameters to sustain overvoltage mitigation during normal operation, while preserving LVRT during faults.