QWQingfeng Wang

Qingfeng Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qingfeng Wang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impedance Mismatch Mechanism and Matching Network Design of Incident End in Single-Core Cable Fault Location of IT System

    by Yanming Han, Qingfeng Wang, Jianqiong Zhang, Xiangqiang Li

    The reliability of the Medium-Voltage Direct-Current (MVDC) power supply system is crucial for train operation, as it powers control, communication, and other critical onboard systems. Accurately locating insulation faults within this system can significantly reduce troubleshooting difficulty and prevent major operational losses. This study addresses a key challenge in applying Time-Domain Reflectometry (TDR) for fault location in single-core cables of IT systems: the incident-end impedance mismatch caused by the variable characteristic impedance of such cables, which fluctuates with installation distance from a ground plane. First, the mechanism through which this mismatch attenuates the primary fault reflection and generates secondary reflections is theoretically modeled. A resistive-capacitive (RC) coupling network is then designed to achieve bidirectional impedance matching between the test equipment and the cable under test while maintaining essential DC isolation. Simulation and experimental results demonstrate that the proposed network effectively mitigates the mismatch issue. In experiments, it increased the proportion of the primary reflected wave entering the receiver by over 30 percentage points and suppressed the secondary reflection by approximately 80%. These improvements enhance waveform clarity and signal strength, directly leading to more accurate fault location. The proposed solution, validated in a railway context, also holds significant potential for improving insulation fault diagnosis in analogous high-voltage cable applications, such as electric vehicle powertrains.


  • Open Access

    A Study on Excitation Inrush Current and Overvoltage Mitigation Strategies Utilizing Phase Selection Control

    by Junting Yan, Qingfeng Wang, Jianqiong Zhang, Xiangqiang Li

    To address the challenges of system failures and equipment damage caused by excitation inrush currents and overvoltages during no-load energization of high-speed locomotive transformers, a simulation model was developed utilizing PSCAD electromagnetic transient simulation software. This study establishes a no-load switching simulation model for rolling stock transformers within PSCAD, analyzing variations in overvoltage and excitation inrush current amplitudes across different phase angles. Additionally, it compares excitation inrush current amplitudes under varying residual magnetism conditions. A phase-selective control strategy is proposed, integrating the hysteresis characteristics of the transformer core. The model’s accuracy is validated against empirical data obtained from a city train. Employing the Jiles–Atherton hysteresis model, the residual magnetism of the transformer core is quantified. Based on measured data, a relationship curve between switching phase and residual magnetism is fitted, enabling calculation of the optimal closing angle through the phase selection procedure. This approach effectively mitigates overvoltage and excitation inrush current hazards, thereby enhancing the operational safety of the train system.


  • Open Access

    Prediction Method of Closing Action Time of Vehicle Pneumatic Main Circuit Breaker Based on PCA and GBDT Algorithm

    by Ruoyu Li, Qingfeng Wang, Jianqiong Zhang, Xiangqiang Li

    The switching action of the main circuit breaker of the train will produce switching overvoltage. In order to suppress the switching overvoltage, the phase selection control of the circuit breaker is required. However, the mechanical structure of the train-mounted electronically controlled pneumatic vacuum main circuit breaker is too complicated, resulting in a large dispersion of its closing action time, which is not suitable for the traditional phase selection control system. In order to obtain the accurate closing action time, a method for predicting the closing action time of train electronically controlled pneumatic vacuum main circuit breaker based on the PCA and GBDT algorithm is proposed. The relationship between the closing phase of AC25 kV power supply train and the peak value of switching overvoltage is obtained by simulation and field test, and the accuracy requirement of the prediction model is determined, that is, the prediction error should be within ±3.3 ms. The final prediction results show that the prediction error of the on-board electronically controlled pneumatic vacuum main circuit breaker closing action time prediction model based on the PCA and GBDT algorithm is controlled within ±3.3 ms, and the probability is 92%, which meets the accuracy requirements of phase selection control.