JYJiaqi Yang

Jiaqi Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiaqi Yang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Single-beam atomic magnetometry with sub-nanotesla heading error based on hyperfine alignment resonances

    by Junlin Chen, Liwei Jiang, Jiaqi Yang, Changhao Zhang, Zhihao Peng, Shihao Bei, Jiali Liu

    Heading error is a major limitation for resonance-based atomic magnetometers operating in the geomagnetic-field range, where the magnetic-field direction often changes with respect to the sensor. Here, we investigate the physical origin of heading error in a single-beam amplitude-modulated nonlinear magneto-optical rotation magnetometer based on the hyperfine alignment resonances of the 87 Rb D1 line in a buffer-gas vapor cell. Unlike orientation-based magnetometers, where nonlinear Zeeman effects usually constitute a major source of heading error, the F = 2 alignment resonance spectrum maintains a stable center frequency under different magnetic-field orientations when the individual resonance components are unresolved. In practical single-beam measurements, the observed heading error is associated with an orientation-dependent residual spectral background, which breaks the apparent symmetry of the alignment-resonance profile and biases the extracted center frequency. To suppress this background-induced bias, we propose a multi-point frequency extraction method that retrieves the resonance center from distorted single-beam spectra. In unshielded geomagnetic-field measurements, the equal-weight pooled peak-to-peak heading-error estimate for the F = 2 manifold is reduced to 0.32 nT, with a one-sided 95% upper coverage limit of 0.90 nT. Separately, an estimated photon-shot-noise-limited sensitivity of about 23   fT / Hz 1 / 2 is obtained. These results provide a compact route to low-heading-error and high-sensitivity atomic magnetometry for practical geomagnetic-field quantum sensing.

  • Model Predictive Control for Real-Time Stabilization of Magnetic Field Using NMOR Atomic Magnetometers

    by Junlin Chen, Liwei Jiang, Ximing Liu, Jiaqi Yang, Jiali Liu, Xin Zhao, Changhao Zhang, Yanchao Chai

    Accurate calibration of atomic magnetometers and the detection of weak magnetic signals in applications such as biomagnetism and fundamental physics experiments are hindered by low-frequency environmental disturbances that mask useful signals. To address this, we implement a magnetic field reference source system that integrates an NMOR atomic magnetometer with a predictive-control-based active compensation loop. The system establishes a quiet and stable magnetic environment, supporting both magnetometer calibration and weak-field measurements. By modeling the NMOR response, the relation between field variation and demodulated phase is derived and used as a robust error signal for stabilization. Under a 10000 nT bias field, the system suppresses low-frequency noise by 42.6 dB compared with passive shielding and achieves residual levels of 264 fT/√Hz at 0.1 Hz. Allan deviation analysis further verifies improved long-term stability, enabling accurate biomagnetic and low-field NMR studies as well as performance evaluation of precision magnetometers.