Yusuke Ueshima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yusuke Ueshima has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Masataka Sakamoto
Department of Radiology Hamamatsu University School of Medicine Shizuoka Japan
2 shared publicationsChie Kurokawa
Faculty of Health Science Juntendo University Tokyo Japan
1 shared publicationEriko Saito
Department of Radiation Oncology Chiba Tokushukai Hospital Chiba Japan
1 shared publication- Hidekazu Suzuki
Department of Radiological Technology, Faculty of Medical Technology, Teikyo University, Tokyo, Japan
1 shared publication - Hiroki Katayama
Department of Clinical Radiology, Kagawa University Hospital, Kagawa, Japan
1 shared publication - Hironori Kojima
Department of Radiology Kanazawa University Hospital Ishikawa Japan
1 shared publication
Latest Publications
- Open Access
- 29 October 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
A multicenter end‐to‐end postal audit of skin markerless surface‐guided radiation therapy
Background: Surface‐guided radiation therapy (SGRT) enables skin markerless positioning, but its accuracy may depend on the reference surface, hardware configuration, commissioning, and institutional workflow. Two reference surfaces are commonly used: a DICOM reference generated from planning CT images and an SGRT reference acquired in the treatment room. Multicenter end‐to‐end data across commercial systems remain limited. Purpose: To evaluate static irradiation accuracy and setup time with two reference surfaces in a nationwide multicenter skin markerless SGRT postal audit. Methods: A prospective end‐to‐end postal audit was conducted from October 2023 to July 2025 at 40 Japanese institutions using five commercial SGRT systems (AlignRT, Catalyst, ExacTrac Dynamic, IDENTIFY, and VOXELAN), eight per system. Each institution received a common phantom package: a breast‐shaped surface phantom, two cubic phantoms containing gold markers, and radiochromic films. Markerless setup and irradiation were performed with both the DICOM and SGRT references; ExacTrac Dynamic institutions performed the DICOM reference setup only. Static irradiation accuracy was the difference between the film‐derived radiation center and the intended center in the DICOM RT Plan; the primary metric was the three‐dimensional translational vector error (3D vector error). Paired comparisons used the Wilcoxon signed‐rank test, and multivariable linear regression evaluated factors associated with both endpoints. Results: Critical setup errors exceeding 5 mm occurred at four institutions initially (institution‐level error rate, 10.0%; three with the DICOM and one with the SGRT reference); one DICOM reference setup was not remeasured and remained out of tolerance, and was excluded as an outlier, leaving 39 DICOM and 31 SGRT reference setups for analysis. Excluding ExacTrac Dynamic, the DICOM reference showed a significantly larger 3D vector error than the SGRT reference (1.54 ± 0.91 vs. 1.20 ± 0.61 mm, p = 0.043). Setup time did not differ between references (86.19 ± 43.57 vs. 81.61 ± 37.09 s, p = 0.804). Axis‐specifically, the difference between references was confined to the anterior–posterior direction (mean absolute difference 0.36 mm, p = 0.002), whereas a caudal superior–inferior offset was present with both (−0.50 ± 1.29 and −0.37 ± 0.87 mm; both p < 0.01) and did not differ between them ( p = 0.854). The 1‐camera condition was independently associated with a larger 3D vector error than the 3‐camera condition (β = 0.90 mm; 95% CI, 0.17–1.63 mm; p = 0.017); no factor was associated with setup time, which showed no correlation with 3D vector error. Conclusions: Skin markerless SGRT achieved millimeter‐level static irradiation accuracy but carried a non‐negligible risk of critical setup errors. The difference between the two reference workflows was confined to the anterior–posterior direction, whereas a superior–inferior offset common to both indicates a residual uncertainty in the audit chain itself. Reference surface selection and camera configuration influenced accuracy, whereas setup time was not a reliable surrogate. These findings highlight the importance of commissioning, standardized reference surface acquisition, routine QA, and independent third‐party audits.
- 29 October 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
Open AccessA multicenter end‐to‐end postal audit of skin markerless surface‐guided radiation therapy
Background: Surface‐guided radiation therapy (SGRT) enables skin markerless positioning, but its accuracy may depend on the reference surface, hardware configuration, commissioning, and institutional workflow. Two reference surfaces are commonly used: a DICOM reference generated from planning CT images and an SGRT reference acquired in the treatment room. Multicenter end‐to‐end data across commercial systems remain limited. Purpose: To evaluate static irradiation accuracy and setup time with two reference surfaces in a nationwide multicenter skin markerless SGRT postal audit. Methods: A prospective end‐to‐end postal audit was conducted from October 2023 to July 2025 at 40 Japanese institutions using five commercial SGRT systems (AlignRT, Catalyst, ExacTrac Dynamic, IDENTIFY, and VOXELAN), eight per system. Each institution received a common phantom package: a breast‐shaped surface phantom, two cubic phantoms containing gold markers, and radiochromic films. Markerless setup and irradiation were performed with both the DICOM and SGRT references; ExacTrac Dynamic institutions performed the DICOM reference setup only. Static irradiation accuracy was the difference between the film‐derived radiation center and the intended center in the DICOM RT Plan; the primary metric was the three‐dimensional translational vector error (3D vector error). Paired comparisons used the Wilcoxon signed‐rank test, and multivariable linear regression evaluated factors associated with both endpoints. Results: Critical setup errors exceeding 5 mm occurred at four institutions initially (institution‐level error rate, 10.0%; three with the DICOM and one with the SGRT reference); one DICOM reference setup was not remeasured and remained out of tolerance, and was excluded as an outlier, leaving 39 DICOM and 31 SGRT reference setups for analysis. Excluding ExacTrac Dynamic, the DICOM reference showed a significantly larger 3D vector error than the SGRT reference (1.54 ± 0.91 vs. 1.20 ± 0.61 mm, p = 0.043). Setup time did not differ between references (86.19 ± 43.57 vs. 81.61 ± 37.09 s, p = 0.804). Axis‐specifically, the difference between references was confined to the anterior–posterior direction (mean absolute difference 0.36 mm, p = 0.002), whereas a caudal superior–inferior offset was present with both (−0.50 ± 1.29 and −0.37 ± 0.87 mm; both p < 0.01) and did not differ between them ( p = 0.854). The 1‐camera condition was independently associated with a larger 3D vector error than the 3‐camera condition (β = 0.90 mm; 95% CI, 0.17–1.63 mm; p = 0.017); no factor was associated with setup time, which showed no correlation with 3D vector error. Conclusions: Skin markerless SGRT achieved millimeter‐level static irradiation accuracy but carried a non‐negligible risk of critical setup errors. The difference between the two reference workflows was confined to the anterior–posterior direction, whereas a superior–inferior offset common to both indicates a residual uncertainty in the audit chain itself. Reference surface selection and camera configuration influenced accuracy, whereas setup time was not a reliable surrogate. These findings highlight the importance of commissioning, standardized reference surface acquisition, routine QA, and independent third‐party audits.
- Open Access
- 10 December 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (12) , e70409
High‐accuracy quality control method of CT system couch tops for treatment planning via an advanced 3D coordinate measuring machine
Background: Quality control (QC) methods for computed tomography (CT) systems used in treatment planning have not been updated since the release of the Task Group (TG) 66 report by the American Association of Physicists in Medicine (AAPM) in 2003. Conventional QC methods for CT systems fail to fulfill the requirements of high‐precision radiation therapy. Moreover, because the geometric accuracy of CT systems can affect the accuracy of radiation therapy, which is particularly critical in high‐precision radiation therapy, a highly accurate QC method is required. Purpose: This study aimed to develop a high‐accuracy QC method for CT system couch tops suitable for high‐precision radiation therapy by utilizing a wide‐area three‐dimensional (3D) coordinate measuring machine (3D‐CMM), a type of laser tracker. Methods: We used a 3D‐CMM, which includes a wireless probe and a camera unit, focusing on a SOMATOM go.Open Pro CT system. The system was set up in accordance with the reference method outlined in the AAPM TG66 report guidelines. The initial phase verified the accuracy of 3D‐CMM measurement within a CT room using a micrometer. Subsequently, a novel continuous measurement method was developed to enable the real‐time tracking of the couch‐top displacement during travel. This new method was evaluated against the standard manual measurement method. Measurements were performed at 0.1 s intervals at various index positions on the couch top, with and without added weight to simulate the presence of a patient. The gathered data were analyzed to assess the couch‐top displacement, horizontality and orthogonality relative to the imaging plane, providing a comprehensive evaluation of the stability and alignment of the couch top. Results: The difference between the micrometer and measured shifts peaked at 0.08 mm. The continuous measurements agreed with the standard measurements within one standard deviation of the three measurements. The maximum displacements of the couch top were 5.23 and 2.00 mm in the vertical axis, with and without a weight load, respectively. There were differences in the displacement at each measurement point. In the lateral axis, the maximum displacements were 2.05 and 2.09 mm with and without a weight load, respectively. The maximum displacement in the imaging plane was observed at approximately half the distance traveled by the couch top. As the couch top traveled, the horizontal angle in the imaging plane of the couch top varied from 0.06° to 0.07° and 0.25° without a weight load and from 0.09° to 0.21° and 0.34° with a weight. The orthogonal angles of the couch top varied from 0.07° to 0.08° and 0.14° without a weight load and from 0.05° to 0.23° and 0.46° with a weight. Conclusions: The developed QC method for the couch tops of CT systems can evaluate the displacement of the couch top and its horizontality and orthogonality to the imaging plane with detailed submillimeter and subdegree accuracy levels. The high‐accuracy QC of CT systems can improve the accuracy of irradiation in radiation therapy.
- 10 December 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (12) , e70409
Open AccessHigh‐accuracy quality control method of CT system couch tops for treatment planning via an advanced 3D coordinate measuring machine
Background: Quality control (QC) methods for computed tomography (CT) systems used in treatment planning have not been updated since the release of the Task Group (TG) 66 report by the American Association of Physicists in Medicine (AAPM) in 2003. Conventional QC methods for CT systems fail to fulfill the requirements of high‐precision radiation therapy. Moreover, because the geometric accuracy of CT systems can affect the accuracy of radiation therapy, which is particularly critical in high‐precision radiation therapy, a highly accurate QC method is required. Purpose: This study aimed to develop a high‐accuracy QC method for CT system couch tops suitable for high‐precision radiation therapy by utilizing a wide‐area three‐dimensional (3D) coordinate measuring machine (3D‐CMM), a type of laser tracker. Methods: We used a 3D‐CMM, which includes a wireless probe and a camera unit, focusing on a SOMATOM go.Open Pro CT system. The system was set up in accordance with the reference method outlined in the AAPM TG66 report guidelines. The initial phase verified the accuracy of 3D‐CMM measurement within a CT room using a micrometer. Subsequently, a novel continuous measurement method was developed to enable the real‐time tracking of the couch‐top displacement during travel. This new method was evaluated against the standard manual measurement method. Measurements were performed at 0.1 s intervals at various index positions on the couch top, with and without added weight to simulate the presence of a patient. The gathered data were analyzed to assess the couch‐top displacement, horizontality and orthogonality relative to the imaging plane, providing a comprehensive evaluation of the stability and alignment of the couch top. Results: The difference between the micrometer and measured shifts peaked at 0.08 mm. The continuous measurements agreed with the standard measurements within one standard deviation of the three measurements. The maximum displacements of the couch top were 5.23 and 2.00 mm in the vertical axis, with and without a weight load, respectively. There were differences in the displacement at each measurement point. In the lateral axis, the maximum displacements were 2.05 and 2.09 mm with and without a weight load, respectively. The maximum displacement in the imaging plane was observed at approximately half the distance traveled by the couch top. As the couch top traveled, the horizontal angle in the imaging plane of the couch top varied from 0.06° to 0.07° and 0.25° without a weight load and from 0.09° to 0.21° and 0.34° with a weight. The orthogonal angles of the couch top varied from 0.07° to 0.08° and 0.14° without a weight load and from 0.05° to 0.23° and 0.46° with a weight. Conclusions: The developed QC method for the couch tops of CT systems can evaluate the displacement of the couch top and its horizontality and orthogonality to the imaging plane with detailed submillimeter and subdegree accuracy levels. The high‐accuracy QC of CT systems can improve the accuracy of irradiation in radiation therapy.