ZZZhengyi Zhong

Zhengyi Zhong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhengyi Zhong has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effects of wound exudate on the discharge characteristic of flexible coplanar dielectric barrier discharge

    by Shuqun Wu, Le Yang, Xinyi Zhang, Zhengyi Zhong, Qiaojue Liu

    The presence of wound exudate on flexible coplanar dielectric barrier discharge (CDBD) devices used for plasma therapy can induce discharge dark regions. However, the effects of exudate volume, spatial distribution, conductivity, and relative permittivity on the discharge dark regions phenomenon has not been systematically quantified. Here we investigate this problem using high‐resolution optical and infrared thermal imaging. To simulate wound exudate, conductivity was controlled using NaCl solutions with defined concentrations, and relative permittivity was adjusted by mixing glycerol with normal saline at defined mass fractions. The dark-region area increased from 0.16 cm 2 to 5.6 cm 2 as the exudate volume increased from 1 μ l to 20 μ l. Over a 60 s period, the dark region shrinks more rapidly when the same 10 μ l exudate is distributed as four droplets rather than one. In contrast, variations in conductivity (0.7–2.0 S m −1 ) and relative permittivity (60–78.5) have little influence on the dark-region area, with changes less than 1 cm 2 . The mechanism is that the high‐conductivity exudate forms an equipotential body on the dielectric surface, locally reducing the electric field below the air breakdown threshold to create the dark region. During continuous discharge, Joule heating and heat transfer from surrounding discharge areas promote exudate evaporation, which restores the local electric field and allows the discharge to recover. By quantitatively investigating the effects of exudate parameters and clarifying the associated electric-field mechanism, this study provides a practical basis for optimizing flexible CDBD device design and exudate-management strategies in wound-healing applications.

  • Design and implementation of a flexible high-voltage pulsed power supply for wearable applications

    by Shuqun Wu, Zheng Qiu, Kehan Qiu, Xinyu Tao, Zhengyi Zhong, Qiaojue Liu

    Kilovolt-level flexible wearable electronic systems are in critical demand for advanced applications spanning healthcare, human-machine interaction, and soft robotics. This paper proposes a flexible high-voltage pulsed power supply based on a multi-stage collaborative step-up architecture. Constructed on the flexible substrate, the power supply integrates a front-end DC Boost converter, a solid-state half-bridge pulse modulator, and an input-parallel output-series micro-transformer network. It employs a non-uniform layout strategy that combines the localized concentration of rigid components with serpentine routing to buffer mechanical deformation. Furthermore, multiphysics finite element models encompassing electric, thermal, and solid mechanics fields were established to systematically validate the design rationale. Experimental evaluations demonstrate that the developed prototype delivers microsecond pulses with a peak voltage amplitude of up to 4.5 kV and a rise time of 250 ns. The highly compact prototype features a total footprint of 13.92 cm 2 and a weight of 5.1 g, while sustaining macroscopic bending angles of up to 120°. Notably, the prototype successfully drives a cold plasma load with an active area of 20 cm 2 . This work validates the novel concept of a flexible kilovolt-level pulsed power supply, overcoming the inherent voltage bottlenecks of wearable electronics and providing a critical hardware foundation for frontier applications such as chronic wound healing, deep neuromodulation, and soft robotics. These results demonstrate the feasibility of a flexible kilovolt-level pulsed power platform and provide an implementation pathway for future flexible systems requiring localized high-electric-field excitation.

  • Comparison of the Exudate Effects on the Flexible Coplanar Dielectric Barrier Discharge Suppressed by Medical Gauze and ePTFE Layers

    by Shixin Zhao, Xinyi Zhang, Zhengyi Zhong, Qiaojue Liu, Shuqun Wu

    Exudate‐induced discharge dark zones pose a major bottleneck for flexible coplanar dielectric barrier discharge (CDBD) devices in wound healing applications, as they compromise treatment uniformity and reliability. To address this, we innovatively compare expanded polytetrafluoroethylene and medical gauze layers introduced onto flexible CDBD devices, focusing on their ability to suppress exudate while maintaining adequate gas transport. The key finding is that gauze consistently outperforms ePTFE in both exudate suppression and gas transport capability. This is probably because that gauze's macroporous network directs liquid through thickness, while ePTFE's micropores induce lateral spreading. These results provide a practical basis for selecting covering materials to stabilize discharge and improve the performance of plasma‐based wound therapy.

  • A multimodal data-driven method for grading the exudate level on the surface of a flexible coplanar dielectric barrier discharge device for wound treatment

    by Shuqun Wu, Miao Lyu, Xinyi Zhang, Zongyong Li, Zhengyi Zhong, Qiaojue Liu

    Real-time assessment of exudate levels under dressing-covered conditions is a critical unmet need in wound treatment using flexible coplanar dielectric barrier discharge (CDBD) patches, as exudate accumulation directly compromises discharge stability and therapeutic efficacy. To address this challenge, we propose a novel data-driven multimodal method for exudate‐level grading that, for the first time, enables grading without removing the dressing. In a simulated gauze‐covered patch application, using physiological saline to mimic exudate, we constructed a synchronized dataset comprising visible‐light discharge images, infrared images, and current waveforms. Four distinct exudate levels were defined. For each modality, dedicated convolutional neural network (CNN) models were developed: two dimensional (2D)‐CNNs for the image modalities and one dimensional (1D)‐CNN for the current time series, with dynamic time warping as a baseline. The results demonstrate that the visible-light 2D-CNN achieves 100% accuracy, the infrared 2D-CNN achieves 98% accuracy, and the current-waveform 1D-CNN achieves an overall accuracy of 99.3%, with class-wise accuracies ranging from 98% to 100%. More importantly, while the visible-light image modality yields the best classification performance under controlled conditions, it requires external optical access, limiting its practical use under dressings. In contrast, the current waveform enables comparably high accuracy without optical observation and is far easier to integrate. These findings indicate that current-waveform-based monitoring is a practical and scalable solution for online exudate monitoring, providing a direct foundation for closed-loop control of CDBD-based wound therapy and representing a significant step toward intelligent, adaptive wound care.


  • High‐Efficiency Bacterial Inactivation of a Plasma Water Treatment System Using Flexible Coplanar Dielectric Barrier Discharge

    by Zhengyi Zhong, Zheng Qiu, Qiaojue Liu, Min Zhu, Haibing Hao, Weiqing Li, Shuqun Wu

    A portable plasma water treatment (PWT) system, integrating a flexible coplanar dielectric barrier discharge (FCDBD) and a bipolar nanosecond pulse generator (BNPG), is designed for water sterilization. The FCDBD produces reactive species that are transported into water as microbubbles. This paper analyzes the discharge characteristics of BNPG‐driven FCDBD via electrical diagnostics, optical emission spectroscopy (OES), liquid‐phase plasma‐activated species diagnostics, and ozone quantification. This FCDBD‐based PWT system achieves a more than 5‐log reduction of Escherichia coli in 800 mL of water within 5 min, yielding a high bacterial inactivation energy efficiency (BIEE) of 3.64 × 10 6 CFU/J. By prolonging the residence time of high‐concentration ozone microbubbles at a low gas flow rate, the system presents a viable approach to outdoor water sterilization.