HZHaochen Zhang

Haochen Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haochen Zhang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Boyang Zhang

    National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China

    1 shared publication
  • Bozhi Ma

    National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China.

    1 shared publication
  • Hongda Li

    National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China

    1 shared publication
  • Junhong Lim

    National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China

    1 shared publication
  • Luming Li

    National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University; IDG/McGovern Institute for Brain Research, Tsinghua University

    1 shared publication
  • Qingyu Yao

    National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China

    1 shared publication

Latest Publications

  • Open Access

    Biphasic Electrostimulation Artifact Model for ECAP Extraction in Spinal Cord Stimulation

    by Haochen Zhang, Xuesong Luo, Bozhi Ma, Luming Li, Xulan Yin, Zhongwei Luo, Boyang Zhang, Xi Zhang, Hongda Li, Qingyu Yao, et al.

    Evoked compound action potential (ECAP) is extensively used as biomarker for neural activity in closed-loop spinal cord stimulation (SCS). However, accurate monitoring of neural activity is challenged by the low signal-to-noise ratio of ECAP recording, primarily due to the interference from stimulation-induced artifacts. This study proposes biphasic electrostimulation artifact model (BEAM) for ECAP extraction and assesses its efficacy using an enhanced quantification approach. The BEAM model is built based on the principle of additivity and incorporates boundary conditions that account for the equivalent electrical environment and temporal relationships. A bilinear growth curve model is introduced to calculate the E-score, enabling a comparison of ECAP extraction results with other methods. The proposed approach is extensively validated using clinical data from nine-month SCS therapy. BEAM method achieves the highest E-scores and reduces stimulation artifacts clinically without distorting information related to neural activity. BEAM accurately characterizes the morphology of artifacts generated by stimulation across various neurostimulation scenarios. Our model may lead to unique interpretation of neural activation in ECAP signals, evoked by electrical stimulation especially in closed-loop controlling strategies that aim to maintain consistent neural excitation.