Junhong Lim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Junhong Lim has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Boyang Zhang
National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China
1 shared publication- Bozhi Ma
National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China.
1 shared publication - Haochen Zhang
National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China
1 shared publication - Hongda Li
National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China
1 shared publication - Luming Li
National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University; IDG/McGovern Institute for Brain Research, Tsinghua University
1 shared publication Qingyu Yao
National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 880-893
Biphasic Electrostimulation Artifact Model for ECAP Extraction in Spinal Cord Stimulation
Evoked compound action potential (ECAP) is extensively used as biomarker for neural activity in closed-loop spinal cord stimulation (SCS). However, accurate monitoring of neural activity is challenged by the low signal-to-noise ratio of ECAP recording, primarily due to the interference from stimulation-induced artifacts. This study proposes biphasic electrostimulation artifact model (BEAM) for ECAP extraction and assesses its efficacy using an enhanced quantification approach. The BEAM model is built based on the principle of additivity and incorporates boundary conditions that account for the equivalent electrical environment and temporal relationships. A bilinear growth curve model is introduced to calculate the E-score, enabling a comparison of ECAP extraction results with other methods. The proposed approach is extensively validated using clinical data from nine-month SCS therapy. BEAM method achieves the highest E-scores and reduces stimulation artifacts clinically without distorting information related to neural activity. BEAM accurately characterizes the morphology of artifacts generated by stimulation across various neurostimulation scenarios. Our model may lead to unique interpretation of neural activation in ECAP signals, evoked by electrical stimulation especially in closed-loop controlling strategies that aim to maintain consistent neural excitation.
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 880-893
Open AccessBiphasic Electrostimulation Artifact Model for ECAP Extraction in Spinal Cord Stimulation
Evoked compound action potential (ECAP) is extensively used as biomarker for neural activity in closed-loop spinal cord stimulation (SCS). However, accurate monitoring of neural activity is challenged by the low signal-to-noise ratio of ECAP recording, primarily due to the interference from stimulation-induced artifacts. This study proposes biphasic electrostimulation artifact model (BEAM) for ECAP extraction and assesses its efficacy using an enhanced quantification approach. The BEAM model is built based on the principle of additivity and incorporates boundary conditions that account for the equivalent electrical environment and temporal relationships. A bilinear growth curve model is introduced to calculate the E-score, enabling a comparison of ECAP extraction results with other methods. The proposed approach is extensively validated using clinical data from nine-month SCS therapy. BEAM method achieves the highest E-scores and reduces stimulation artifacts clinically without distorting information related to neural activity. BEAM accurately characterizes the morphology of artifacts generated by stimulation across various neurostimulation scenarios. Our model may lead to unique interpretation of neural activation in ECAP signals, evoked by electrical stimulation especially in closed-loop controlling strategies that aim to maintain consistent neural excitation.