Erica J. W. Rossi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Erica J. W. Rossi has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- James Tung
University of Waterloo
2 shared publications - Run Ze Gao
Sunnybrook Research Institute, Toronto, Ontario, Canada
2 shared publications - Amanda Lee Mayo
The Division of Physical Medicine and Rehabilitation, Temerty School of Medicine, University of Toronto, Toronto, Ontario, Canada
1 shared publication Andreas Schirm
Prosthetic Ability
1 shared publicationArezoo Eshraghi
West Park Healthcare Centre, University Health Network, Toronto, Ontario, Canada
1 shared publication- Bram Kok
Winnipeg Prosthetics & Orthotics, Winnipeg, Manitoba, Canada
1 shared publication
Latest Publications
- Open Access
- 23 June 2026
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 9 (2) , 46848
DEVELOPING A RESEARCH AGENDA IN DIGITAL WORKFLOWS FOR THE FABRICATION OF PROSTHESES AND ORTHOSES
BACKGROUND: Recent advancements in digital workflows, including the use of 3D printing, are transforming the prosthetics and orthotics (P&O) field. Digital technologies offer opportunities to deliver P&O services that are more efficient by reducing design and fabrication times, are less wasteful through the elimination or reduction of consumables, including plaster, foam and other materials, and are more repeatable by having digitally saved designs. Despite known advantages, the adoption of digital workflows in P&O has been inconsistent, underscoring the need for cross-sector collaboration to guide the field using evidence-informed approaches. OBJECTIVE: To collaborate with key interest groups to identify priority areas for advancing the adoption and implementation of digital workflows in the P&O field. METHODOLOGY: A modified Delphi approach was used to inform the structure of a Canada-wide initiative and involved participation of 79 representatives from key interest groups, including prosthetists, orthotists, technicians, biomedical engineers, researchers, and people with limb absence/difference. Research priorities were identified through online surveys followed by a hybrid meeting during which attendees engaged in small- and large-group discussions to refine and select priorities. RESULTS: Five key digital P&O research priorities were identified: (1) strengthening evidence on device quality and system performance compared to traditional methods; (2) developing economic and reimbursement models to support clinical integration; (3) improving education and training for digital workflows; (4) establishing standardized practice guidelines; and (5) increasing key interest group engagement to better understand user needs and perspectives. While the general components of digital workflows are now broadly understood, future efforts should focus on more specific contexts, and discussions should be more targeted and disaggregated (e.g., by device type, patient population, or care setting) and include experts with context-specific experience. CONCLUSION: This collaboration initiative provides a strategic roadmap for advancing the adoption of digital workflows in the P&O field and supports the development of national collaborations aimed at fostering innovations and evidence-based practice. Layman's Abstract Recent advances in digital technologies, including three-dimensional (3D) printing, are changing how prostheses and orthoses are designed and fabricated. Digital workflows are the processes of using digital technologies to design and create prostheses or orthoses. These approaches may improve prostheses and orthoses care by reducing design and fabrication time, decreasing waste by reducing the use of plaster and other materials, and improving consistency by allowing designs to be digitally stored and reused. Despite these potential benefits, digital workflows are not yet widely used in clinical practice. Barriers such as limited evidence, gaps in education and training, cost and reimbursement challenges, and a lack of shared standards have slowed adoption. To help address these challenges, a Canada-wide initiative was conducted to bring together key interest groups and develop a shared research agenda. Using a structured consensus-building approach, 79 invitees (including prosthetists, orthotists, biomedical engineers, researchers, and people who use prostheses and/or orthoses) contributed through online surveys and a hybrid meeting that included group discussions. Five main research priorities were identified: generating stronger evidence comparing digitally produced prostheses or orthoses with traditionally made devices, improving education and training for digital workflows, developing economic and reimbursement models that support routine clinical use, creating baseline guidelines to promote consistent and safe practices, and increasing engagement with key interest groups to better understand their perspectives and needs. Overall, this work provides a roadmap to guide future initiatives and collaboration, supporting innovation and evidence-informed use of digital workflows in prostheses and orthoses care. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/46848/35280 How To Cite: Andrysek J, Mayo A.L, Ngan C.C, Blocka D, Pendse V, Calovini E, et al. Developing a research agenda in digital workflows for the fabrication of prostheses and orthoses. Can Prosthet Orthot J. 2026;9(2):4. https://doi.org/10.33137/cpoj.v9i2.46848 Corresponding Author: Prof. Jan Andrysek, PhDAffiliation: 1) Bloorview Research Institute, Holland Bloorview Kids Rehabilitation Hospital, Toronto, Ontario, Canada; 2) Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada.E-Mail: JAndrysek@hollandbloorview.caORCID ID: https://orcid.org/0000-0002-4976-1228
- 23 June 2026
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 9 (2) , 46848
Open AccessDEVELOPING A RESEARCH AGENDA IN DIGITAL WORKFLOWS FOR THE FABRICATION OF PROSTHESES AND ORTHOSES
BACKGROUND: Recent advancements in digital workflows, including the use of 3D printing, are transforming the prosthetics and orthotics (P&O) field. Digital technologies offer opportunities to deliver P&O services that are more efficient by reducing design and fabrication times, are less wasteful through the elimination or reduction of consumables, including plaster, foam and other materials, and are more repeatable by having digitally saved designs. Despite known advantages, the adoption of digital workflows in P&O has been inconsistent, underscoring the need for cross-sector collaboration to guide the field using evidence-informed approaches. OBJECTIVE: To collaborate with key interest groups to identify priority areas for advancing the adoption and implementation of digital workflows in the P&O field. METHODOLOGY: A modified Delphi approach was used to inform the structure of a Canada-wide initiative and involved participation of 79 representatives from key interest groups, including prosthetists, orthotists, technicians, biomedical engineers, researchers, and people with limb absence/difference. Research priorities were identified through online surveys followed by a hybrid meeting during which attendees engaged in small- and large-group discussions to refine and select priorities. RESULTS: Five key digital P&O research priorities were identified: (1) strengthening evidence on device quality and system performance compared to traditional methods; (2) developing economic and reimbursement models to support clinical integration; (3) improving education and training for digital workflows; (4) establishing standardized practice guidelines; and (5) increasing key interest group engagement to better understand user needs and perspectives. While the general components of digital workflows are now broadly understood, future efforts should focus on more specific contexts, and discussions should be more targeted and disaggregated (e.g., by device type, patient population, or care setting) and include experts with context-specific experience. CONCLUSION: This collaboration initiative provides a strategic roadmap for advancing the adoption of digital workflows in the P&O field and supports the development of national collaborations aimed at fostering innovations and evidence-based practice. Layman's Abstract Recent advances in digital technologies, including three-dimensional (3D) printing, are changing how prostheses and orthoses are designed and fabricated. Digital workflows are the processes of using digital technologies to design and create prostheses or orthoses. These approaches may improve prostheses and orthoses care by reducing design and fabrication time, decreasing waste by reducing the use of plaster and other materials, and improving consistency by allowing designs to be digitally stored and reused. Despite these potential benefits, digital workflows are not yet widely used in clinical practice. Barriers such as limited evidence, gaps in education and training, cost and reimbursement challenges, and a lack of shared standards have slowed adoption. To help address these challenges, a Canada-wide initiative was conducted to bring together key interest groups and develop a shared research agenda. Using a structured consensus-building approach, 79 invitees (including prosthetists, orthotists, biomedical engineers, researchers, and people who use prostheses and/or orthoses) contributed through online surveys and a hybrid meeting that included group discussions. Five main research priorities were identified: generating stronger evidence comparing digitally produced prostheses or orthoses with traditionally made devices, improving education and training for digital workflows, developing economic and reimbursement models that support routine clinical use, creating baseline guidelines to promote consistent and safe practices, and increasing engagement with key interest groups to better understand their perspectives and needs. Overall, this work provides a roadmap to guide future initiatives and collaboration, supporting innovation and evidence-informed use of digital workflows in prostheses and orthoses care. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/46848/35280 How To Cite: Andrysek J, Mayo A.L, Ngan C.C, Blocka D, Pendse V, Calovini E, et al. Developing a research agenda in digital workflows for the fabrication of prostheses and orthoses. Can Prosthet Orthot J. 2026;9(2):4. https://doi.org/10.33137/cpoj.v9i2.46848 Corresponding Author: Prof. Jan Andrysek, PhDAffiliation: 1) Bloorview Research Institute, Holland Bloorview Kids Rehabilitation Hospital, Toronto, Ontario, Canada; 2) Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada.E-Mail: JAndrysek@hollandbloorview.caORCID ID: https://orcid.org/0000-0002-4976-1228
- 1 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (3) , 1221-1235
Soft Dynamic Fluidic Cushion for Pressure Sore Management in Transtibial Prosthetics: A Proof-of-Concept Study
Objective: Due to volume fluctuations, bony prominences contacting prosthetic sockets are susceptible to skin breakdown due to constant pressure and shear stresses from lateral and vertical displacements throughout gait. A low-profile unloading cushion that can be controlled with a millisecond response to dynamically provide localized socket fit at the fibular head may offer stress relief during gait. Methods: The study presents a low-profile (<0.5 mm thick) dynamic fluidic cushion that can provide targeted cushioning during gait to mitigate high contact pressures at bony prominences while minimizing duration of pressure and shear. The proof-of-concept study comprised benchtop testing using a residual limb model. Results: The dynamic cushion effectively unloaded high pressure caused by the body weights only during the stance phase at the fibular head for up to 80 kg by mitigating and redistributing contact pressures away from the fibular head to the immediately surrounding soft tissues. Results demonstrated that the fibular head peak contact pressure could be reduced by as much as 94% (98 to 6 kPa) with a response time of 250 milliseconds in benchtop tests, fast enough to turn on during stance and off during swing. Conclusion: The proposed dynamic fluidic cushion has the potential to offer unloading during gait to prevent skin damage at pressure-sensitive spots, notably benefiting individuals with complex limb geometries. Significance: We introduce a new method with the potential to be integrated into prosthetist workflows to locally adjust socket fit (e.g., at the fibular head) using elastomer sheets and a handheld heat press.
- 1 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (3) , 1221-1235
Soft Dynamic Fluidic Cushion for Pressure Sore Management in Transtibial Prosthetics: A Proof-of-Concept Study
Objective: Due to volume fluctuations, bony prominences contacting prosthetic sockets are susceptible to skin breakdown due to constant pressure and shear stresses from lateral and vertical displacements throughout gait. A low-profile unloading cushion that can be controlled with a millisecond response to dynamically provide localized socket fit at the fibular head may offer stress relief during gait. Methods: The study presents a low-profile (<0.5 mm thick) dynamic fluidic cushion that can provide targeted cushioning during gait to mitigate high contact pressures at bony prominences while minimizing duration of pressure and shear. The proof-of-concept study comprised benchtop testing using a residual limb model. Results: The dynamic cushion effectively unloaded high pressure caused by the body weights only during the stance phase at the fibular head for up to 80 kg by mitigating and redistributing contact pressures away from the fibular head to the immediately surrounding soft tissues. Results demonstrated that the fibular head peak contact pressure could be reduced by as much as 94% (98 to 6 kPa) with a response time of 250 milliseconds in benchtop tests, fast enough to turn on during stance and off during swing. Conclusion: The proposed dynamic fluidic cushion has the potential to offer unloading during gait to prevent skin damage at pressure-sensitive spots, notably benefiting individuals with complex limb geometries. Significance: We introduce a new method with the potential to be integrated into prosthetist workflows to locally adjust socket fit (e.g., at the fibular head) using elastomer sheets and a handheld heat press.